A real-time, quantitative PCR method using hydrolysis probes for the monitoring of Plasmodium falciparum load in experimentally infected human volunteers

被引:83
作者
Rockett, Rebecca J.
Tozer, Sarah J.
Peatey, Chris [1 ]
Bialasiewicz, Seweryn
Whiley, David M.
Nissen, Michael D.
Trenholme, Katharine [1 ]
Mc Carthy, James S. [2 ]
Sloots, Theo P.
机构
[1] Queensland Inst Med Res, Malaria Biol Lab, Brisbane, Qld 4006, Australia
[2] Univ Queensland, Queensland Inst Med Res, Clin Trop Med Lab, Brisbane, Qld 4072, Australia
来源
MALARIA JOURNAL | 2011年 / 10卷
关键词
POLYMERASE-CHAIN-REACTION; MALARIA PARASITES; BLOOD;
D O I
10.1186/1475-2875-10-48
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
Background: The accurate quantification of Plasmodium falciparum parasite numbers by PCR is an important tool for monitoring growth kinetics in subjects infected and subsequently treated with anti-malarial agents. Methods: A real-time quantitative PCR (rt-qPCR) method using primers and a hydrolysis probe that targets the 18S rRNA gene was adapted and optimized to estimate parasite load in blood samples. Samples included laboratory prepared blood samples of varying parasite concentrations (6.4 x 10(5) to 6.4 parasites per 500 mu l of packed red blood cells (500pRBC)) and blood samples collected from an experimentally infected human subject collected at 19 time points over 10 days. Sample preparation and extraction, detection chemistry, assay reproducibility, and limit of detection were compared to a previously published SYBR Green rt-qPCR used in a malaria vaccine clinical trial. Results: Both the rt-qPCR hydrolysis probe assay and SYBR Green rt-qPCR provided a limit of detection of 6.4 x 101 parasites per 500pRBC. However non-specific amplification in the SYBR Green rt-qPCR assay led to either inaccurate estimation of parasite load at levels below 6.4 x 102 parasites per 500pRBC and to false-positive detection of parasites in negative samples. The rt-qPCR hydrolysis probe assay was specific and provided reliable quantification of parasitaemia down to 6.4 x 10(1) parasites per 500pRBC. Notably, 12 of the 19 consecutive samples collected from the experimentally infected subject were at or below 6.4 x 10(2) copies per 500pRBC. Conclusions: These results show that the hydrolysis probe rt-qPCR assay is superior to the SYBR Green rt-qPCR for the quantification of P. falciparum in human blood samples. The hydrolysis probe rt-qPCR is now in use in the Queensland paediatric infectious diseases laboratory (QPID) to monitor parasitaemia in experimentally-infected clinical trial subjects.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] Quantitative detection method for Roundup Ready® soybean in food using duplex real-time PCR MGB chemistry
    Samson, Maria Cristina
    Gulli, Mariolina
    Marmiroli, Nelson
    JOURNAL OF THE SCIENCE OF FOOD AND AGRICULTURE, 2010, 90 (09) : 1437 - 1444
  • [32] Quantification of Trypanosoma evansi parasitic load in experimentally infected mice using real time PCR assay and its comparative evaluation with conventional parasitological techniques
    Kankar, Shashi Kant
    Kumar, Rajender
    Goyal, Sachin Kumar
    Gaur, Deepak Kumar
    Sharma, Parvati
    Bera, B. C.
    Garg, Rajat
    Kumar, Sanjay
    Yadav, S. C.
    INDIAN JOURNAL OF ANIMAL SCIENCES, 2016, 86 (12) : 1378 - 1384
  • [33] Validation of Reference Genes for Gene Expression Studies in Virus-Infected Nicotiana benthamiana Using Quantitative Real-Time PCR
    Liu, Deshui
    Shi, Lindan
    Han, Chenggui
    Yu, Jialin
    Li, Dawei
    Zhang, Yongliang
    PLOS ONE, 2012, 7 (09):
  • [34] Development of a real-time PCR method for rapid sexing of human preimplantation embryos
    Martinhago, C. D.
    Vagnini, L. D.
    Petersen, C. G.
    Mauri, A. L.
    Baruffi, R. L.
    de Oliveira, R. M.
    Franco, J. G., Jr.
    REPRODUCTIVE BIOMEDICINE ONLINE, 2010, 20 (01) : 75 - 82
  • [35] A standard additions method reduces inhibitor-induced bias in quantitative real-time PCR
    Ellison, Stephen L. R.
    Emslie, Kerry R.
    Kassir, Zena
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2011, 401 (10) : 3221 - 3227
  • [36] Development of Quantitative Duplex Real-Time PCR Method for Screening Analysis of Genetically Modified Maize
    Oguchi, Taichi
    Onishi, Mari
    Minegishi, Yasutaka
    Kurosawa, Yasunori
    Kasahara, Masaki
    Akiyama, Hiroshi
    Teshima, Reiko
    Futo, Satoshi
    Furui, Satoshi
    Hino, Akihiro
    Kitta, Kazumi
    JOURNAL OF THE FOOD HYGIENIC SOCIETY OF JAPAN, 2009, 50 (03): : 117 - 125
  • [37] A Comparison of Real-Time PCR Protocols for the Quantitative Monitoring of Asymptomatic Olive Infections by Verticillium dahliae Pathotypes
    Gramaje, D.
    Perez-Serrano, V.
    Montes-Borrego, M.
    Navas-Cortes, J. A.
    Jimenez-Diaz, R. M.
    Landa, B. B.
    PHYTOPATHOLOGY, 2013, 103 (10) : 1058 - 1068
  • [38] An overview of technical considerations when using quantitative real-time PCR analysis of gene expression in human exercise research
    Kuang, Jujiao
    Yan, Xu
    Genders, Amanda J.
    Granata, Cesare
    Bishop, David J.
    PLOS ONE, 2018, 13 (05):
  • [39] Internal Validation of Human Mitochondrial DNA Quantification Using Real-Time PCR
    Sprouse, Marc L.
    Phillips, Nicole R.
    Kavlick, Mark F.
    Roby, Rhonda K.
    JOURNAL OF FORENSIC SCIENCES, 2014, 59 (04) : 1049 - 1056
  • [40] The use of real-time PCR for quantitative determination of some propionic bacteria inhabiting the human skin
    Globa A.G.
    Alekseev Ya.I.
    Arzumanyan V.G.
    Zaborova V.A.
    Guridov A.A.
    Biochemistry (Moscow) Supplement Series B: Biomedical Chemistry, 2013, 7 (2) : 175 - 177