Prediction error after pediatric cataract surgery with intraocular lens implantation: Contact versus immersion A-scan biometry

被引:31
作者
Trivedi, Rupal H. [1 ]
Wilson, M. Edward [1 ]
机构
[1] Med Univ S Carolina, Storm Eye Inst, Dept Ophthalmol, Miles Ctr Pediat Ophthalmol, Charleston, SC 29425 USA
关键词
AXIAL LENGTH MEASUREMENT; POWER CALCULATION; MYOPIC SHIFT; PSEUDOPHAKIA; ACCURACY; OUTCOMES; CHILDREN; INFANTS;
D O I
10.1016/j.jcrs.2010.09.023
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To evaluate the accuracy of pediatric intraocular lens (IOL) calculations performed using contact and immersion A-scan biometry. SETTING: Storm Eye Institute, Charleston, South Carolina, USA. DESIGN: Evaluation of diagnostic test or technology. METHODS: Data from a prospective study of pediatric eyes that had in-the-bag implantation of an AcrySof SN6OWF IOL and had refraction results available from 14 days to 3 months postoperatively were retrospectively analyzed. The contact and immersion A-scan biometry techniques were performed in each eye and compared. RESULTS: The mean age at surgery of the 22 patients (22 eyes) was 4.8 years +/- 4.1 (SD). The mean prediction error was + 0.4 +/- 0.7 diopter (D) in the contact group and -0.4 +/- 0.8 D in the immersion group (P < .001) and the mean absolute prediction error, 0.7 +/- 0.4 D and 0.7 +/- 0.6 D, respectively (P = .694). The absolute prediction error was less than 0.5 D in 5 eyes (23%) using the contact technique and 11 eyes (50%) using the immersion technique. The mean postoperative spherical equivalent was +2.9 +/- 2.5 D, which was significantly different from the mean predicted refraction for contact A-scan (3.3 +/- 2.8 D; P = .010) but not immersion A-scan (2.5 +/- 2.5 D; P = .065). CONCLUSIONS: There was a significant difference in prediction error between postoperative refractive results obtained with contact biometry and immersion A-scan biometry in children. Based on the results, the immersion A-scan technique is recommended for pediatric IOL power calculation.
引用
收藏
页码:501 / 505
页数:5
相关论文
共 40 条
[31]   Changes in axial length growth after congenital cataract surgery and intraocular lens implantation in children younger than 5 years [J].
Hussin, Hussin M. ;
Markham, Richard .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (07) :1223-1228
[32]   Corrected and Uncorrected Near and Distance Vision with ReSTOR® Compared to Monofocal Intraocular Lens Implantation after Cataract Surgery: A Pooled Analysis [J].
Cochener, Beatrice ;
Arnould, Benoit ;
Viala, Muriel ;
de Climens, Aude Roborel ;
Berdeaux, Gilles .
OPHTHALMOLOGICA, 2009, 223 (02) :128-135
[33]   Comparison of intraocular lens tilt after capsular sutured scleral fixation with capsular segments versus uneventful cataract surgery [J].
Chang-Sotomayor, Meilin ;
Guell, Jose L. ;
Silva, Ma Victoria de Rojas ;
Corretger, Xavier ;
Bandeira, Francisco ;
Mendez-Mourelle, Andrea ;
Veillet, Lorea Zurutuza ;
Adan, Alfredo ;
Figueras-Roca, Marc .
EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2024, 34 (05) :1450-1457
[34]   Factors affecting prediction error after cataract surgery with implantation of various multifocal IOLs in patients with previous refractive laser surgery [J].
Yoo, Young-Sik ;
Kang, Min Chae ;
Park, Jongyeop ;
Kwon, Hyung-Goo ;
Chung, Eui-Sang ;
Lim, Dong Hui ;
Chung, Tae-Young .
ANNALS OF TRANSLATIONAL MEDICINE, 2021, 9 (23)
[35]   Femtosecond laser-assisted cataract surgery with implantation of a diffractive trifocal intraocular lens after laser in situ keratomileusis: a case report [J].
Wang, Wei ;
Ni, Shuang ;
Li, Xi ;
Chen, Xiang ;
Zhu, Yanan ;
Xu, Wen .
BMC OPHTHALMOLOGY, 2018, 18
[36]   Factors associated with good near vision after cataract surgery with monofocal intraocular lens implantation at a tertiary eye hospital in southern India [J].
Kaup, Soujanya ;
Charugundla, Abhilasha ;
Shivalli, Siddharudha .
SAUDI JOURNAL OF OPHTHALMOLOGY, 2022, 36 (02) :224-228
[37]   Refractive Error Prediction After Phacoemulsification Surgery: Lenstar LS 900 Versus Nidek AL-Scan [J].
Cakir, Gulay Yalcinkaya ;
Kirgiz, Ahmet ;
Uzar, Ibrahim ;
Besek, Nilay Kandemir ;
Ahmet, Sibel ;
Atik, Burcu Kemer ;
Uzun, Seda Liman ;
Taskapili, Muhittin .
JOURNAL OF REFRACTIVE SURGERY, 2025, 41 (03) :E257-E263
[38]   Power prediction for one-piece and three-piece intraocular lens implantation after cataract surgery in patients with chronic angle-closure glaucoma: a prospective, randomized clinical trial [J].
Rhiu, Soolienah ;
Lee, Eun Suk ;
Kim, Tae-im ;
Lee, Hye Sun ;
Kim, Chan Yun .
ACTA OPHTHALMOLOGICA, 2012, 90 (08) :e580-e585
[39]   Short-Term Changes in Prediction Error after Cataract Surgery in Eyes Receiving 1 of 3 Types of Single-Piece Acrylic Intraocular Lenses [J].
Hayashi, Ken ;
Yoshida, Motoaki ;
Hayashi, Shunsuke ;
Yoshimura, Koichi .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2020, 219 :12-20
[40]   Relationship between preoperative axial length and myopic shift over 3 years after congenital cataract surgery with primary intraocular lens implantation at the National Institute of Ophthalmology of Peru, 2007-2011 [J].
Valera Cornejo, Diego Alejandro ;
Flores Boza, Abel .
CLINICAL OPHTHALMOLOGY, 2018, 12 :395-399