The stabilizing potential of anterior, posterior and combined techniques for the reconstruction of a 2-level cervical corpectomy model: biomechanical study and first results of ATPS prototyping

被引:37
作者
Koller, Heiko [1 ,2 ]
Schmidt, Rene [3 ]
Mayer, Michael [2 ]
Hitzl, Wolfgang [4 ]
Zenner, Juliane [1 ]
Middendorf, Stefan [5 ]
Graef, Nicolaus [5 ]
Resch, H. [2 ]
Willke, Hans-Joachim [5 ]
机构
[1] Werner Wicker Clin, German Scoliosis Ctr, Bad Wildungen, Germany
[2] Paracelsus Med Univ, Dept Traumatol & Sport Injuries, Salzburg, Austria
[3] Univ Med Ctr, Dept Orthoped & Traumatol, Mannheim, Germany
[4] Paracelsus Med Univ, Dept Biostat, Res Off, Salzburg, Austria
[5] Univ Ulm, Dept Orthoped Res & Biomech, Ulm, Germany
关键词
Cervical spine; Biomechanical study; Corpectomy; Pedicle screw; Reconstruction; TRANSPEDICULAR SCREW FIXATION; PEDICLE SCREW; CERVICOTHORACIC JUNCTION; PLATE CONSTRUCTS; SPINAL-FUSION; INSERTION; ACCURACY; INSTRUMENTATION; COMPLICATIONS; DECOMPRESSION;
D O I
10.1007/s00586-010-1503-x
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Clinical studies reported frequent failure with anterior instrumented multilevel cervical corpectomies. Hence, posterior augmentation was recommended but necessitates a second approach. Thus, an author group evaluated the feasibility, pull-out characteristics, and accuracy of anterior transpedicular screw (ATPS) fixation. Although first success with clinical application of ATPS has already been reported, no data exist on biomechanical characteristics of an ATPS-plate system enabling transpedicular end-level fixation in advanced instabilities. Therefore, we evaluated biomechanical qualities of an ATPS prototype C4-C7 for reduction of range of motion (ROM) and primary stability in a non-destructive setup among five constructs: anterior plate, posterior all-lateral mass screw construct, posterior construct with lateral mass screws C5 + C6 and end-level fixation using pedicle screws unilaterally or bilaterally, and a 360A degrees construct. 12 human spines C3-T1 were divided into two groups. Four constructs were tested in group 1 and three in group 2; the ATPS prototypes were tested in both groups. Specimens were subjected to flexibility test in a spine motion tester at intact state and after 2-level corpectomy C5-C6 with subsequent reconstruction using a distractable cage and one of the osteosynthesis mentioned above. ROM in flexion-extension, axial rotation, and lateral bending was reported as normalized values. All instrumentations but the anterior plate showed significant reduction of ROM for all directions compared to the intact state. The 360A degrees construct outperformed all others in terms of reducing ROM. While there were no significant differences between the 360A degrees and posterior constructs in flexion-extension and lateral bending, the 360A degrees constructs were significantly more stable in axial rotation. Concerning primary stability of ATPS prototypes, there were no significant differences compared to posterior-only constructs in flexion-extension and axial rotation. The 360A degrees construct showed significant differences to the ATPS prototypes in flexion-extension, while no significant differences existed in axial rotation. But in lateral bending, the ATPS prototype and the anterior plate performed significantly worse than the posterior constructs. ATPS was shown to confer increased primary stability compared to the anterior plate in flexion-extension and axial rotation with the latter yielding significance. We showed that primary stability after 2-level corpectomy reconstruction using ATPS prototypes compared favorably to posterior systems and superior to anterior plates. From the biomechanical point, the 360A degrees instrumentation was shown the most efficient for reconstruction of 2-level corpectomies. Further studies will elucidate whether fatigue testing will enhance the benefit of transpedicular anchorage with posterior constructs and ATPS.
引用
收藏
页码:2137 / 2148
页数:12
相关论文
共 64 条
[1]   Morphometric and Volumetric Analysis of the Lateral Masses of the Lower Cervical Spine [J].
Abdullah, Kalil G. ;
Steinmetz, Michael P. ;
Mroz, Thomas E. .
SPINE, 2009, 34 (14) :1476-1479
[2]  
ABUMI K, 1999, SPINE, V24, P2456, DOI DOI 10.1097/00007632-199912010-00006
[3]   Long-term biomechanical stability and clinical improvement after extended multilevel corpectomy and circumferential reconstruction of the cervical spine using titanium mesh cages [J].
Acosta, Frank L., Jr. ;
Aryan, Henry E. ;
Chou, Dean ;
Ames, Christopher P. .
JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2008, 21 (03) :165-174
[4]   Biomechanics of stabilization after cervicothoracic compression-flexion injury [J].
Ames, CP ;
Bozkus, MH ;
Chamberlain, RH ;
Acosta, FL ;
Papadopoulos, SM ;
Sonntag, VKH ;
Crawford, NR .
SPINE, 2005, 30 (13) :1505-1512
[5]   Anterior pedicle screw fixation for multilevel cervical corpectomy and spinal fusion [J].
Aramomi, M. ;
Masaki, Y. ;
Koshizuka, S. ;
Kadota, R. ;
Okawa, A. ;
Koda, M. ;
Yamazaki, M. .
ACTA NEUROCHIRURGICA, 2008, 150 (06) :575-582
[6]   Successful treatment of cervical myelopathy with minimal morbidity by circumferential decompression and fusion [J].
Aryan, Henry E. ;
Sanchez-Mejia, Rene O. ;
Ben-Haim, Sharona ;
Ames, Christopher P. .
EUROPEAN SPINE JOURNAL, 2007, 16 (09) :1401-1409
[7]   Biomechanics of the cervical spine. I: Normal kinematics [J].
Bogduk, N ;
Mercer, S .
CLINICAL BIOMECHANICS, 2000, 15 (09) :633-648
[8]   Biomechanical analysis of rigid stabilization techniques for three-column injury in the lower cervical spine [J].
Bozkus, H ;
Ames, CP ;
Chamberlain, RH ;
Nottmeier, EW ;
Sonntag, VKH ;
Papadopoulos, SM ;
Crawford, NR .
SPINE, 2005, 30 (08) :915-922
[9]  
Bransford RJ, 2009, 16 INT M ADV SPIN TE
[10]   Comparison of multisegment anterior cervical fixation using bone strut graft versus a titanium rod and buttress prosthesis -: Analysis of outcome with long-term follow-up and interview by independent physician [J].
Brazenor, Graeme Alexander .
SPINE, 2007, 32 (01) :63-71