There is considerable interest in quantifying morphine and its major metabolites, morphine-3-glucuronide (M3G) and morphine-6-glucuronide (M6G). Available assays use gas chromatography-mass spectrometry or high-performance liquid chromatography (HPLC) with single or tandem mass spectrometry, ultraviolet, electrochemical, or fluorimetric detection. Nevertheless, few methods provide adequate sensitivity for all analytes, in a single injection, with the desired rate of sample throughput. A rapid and sensitive method for quantification of morphine, M3G and M6G from human plasma using HPLC with electrospray ionization mass spectrometry was developed using a Waters Oasis MCX 96-well plate for extracting both lipophilic morphine and its hydrophilic glucuronides, C18 separation using an isocratic mobile phase (methanol, acetonitrile and formic acid), and selected ion monitoring. Recoveries of morphine, M3G and M6G, respectively, were 81, 90 and 82% at the low (2, 25 and 2 ng/ml), 80, 77 and 75% at the medium (10, 250 and 10 ng/ml), and 74, 62 and 72% at the high (100, 1000 and 100 ng/ml) quality control samples. The limit of quantitation was 0.5 ng/ml morphine and M6G, and 5 ng/ml M3G. Analytes were validated over a linear range of 0.5-200 ng/ml morphine and M6G, and 5-2000 ng/ml M3G. This assay represents an improvement over existing methods through solid phase extraction with increased sample throughput (96-well plates), use of small samples (0.5 ml), and sub-nanogram detection. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:95 / 103
页数:9
相关论文
共 50 条
  • [11] Simultaneous determination of morphine and its glucuronides in rat hair and rat plasma by reversed-phase liquid chromatography with electrospray ionization mass spectrometry
    Toyo'oka, T
    Yano, M
    Kato, M
    Nakahara, Y
    ANALYST, 2001, 126 (08) : 1339 - 1345
  • [12] Determination of (R)- and (S)-ketoprofen in human plasma by liquid chromatography/tandem mass spectrometry following automated solid-phase extraction in the 96-well format
    Eichhold, TH
    Bailey, RE
    Tanguay, SL
    Hoke, SH
    JOURNAL OF MASS SPECTROMETRY, 2000, 35 (04): : 504 - 511
  • [13] RAPID AND HIGHLY AUTOMATED-DETERMINATION OF MORPHINE AND MORPHINE GLUCURONIDES IN PLASMA BY ONLINE SOLID-PHASE EXTRACTION AND COLUMN LIQUID-CHROMATOGRAPHY
    HUWYLER, J
    RUFER, S
    KUSTERS, E
    DREWE, J
    JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1995, 674 (01): : 57 - 63
  • [14] A highly automated 96-well solid phase extraction and liquid chromatography/tandem mass spectrometry method for the determination of fentanyl in human plasma
    Shou, WZ
    Jiang, XY
    Beato, BD
    Weng, ND
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2001, 15 (07) : 466 - 476
  • [15] Comparison of solid-phase extraction methods for the determination of azaspiracids in shellfish by liquid chromatography-electrospray mass spectrometry
    Moroney, C
    Lehane, M
    Braña-Magdalena, A
    Furey, A
    James, KJ
    JOURNAL OF CHROMATOGRAPHY A, 2002, 963 (1-2) : 353 - 361
  • [16] Factorial design for the development of automated solid-phase extraction in the 96-well format for determination of tesaglitazar, in plasma, by liquid chromatography-mass spectrometry
    Svennberg, H
    Bergh, S
    Stenhoff, H
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 787 (02): : 231 - 241
  • [17] Determination of benzodiazepines in human urine using solid-phase extraction and high-performance liquid chromatography-electrospray ionization tandern mass spectrometry
    Hegstad, S
    Oiestad, EL
    Johansen, U
    Christophersen, AS
    JOURNAL OF ANALYTICAL TOXICOLOGY, 2006, 30 (01) : 31 - 37
  • [18] Determination of berberine in human plasma by liquid chromatography-electrospray ionization-mass spectrometry
    Hua, Wenyan
    Ding, Li
    Chen, Yan
    Gong, Bin
    He, Jianchang
    Xu, Guili
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2007, 44 (04) : 931 - 937
  • [19] Determination of glimepiride in human plasma by liquid chromatography-electrospray ionization tandem mass spectrometry
    Salem, II
    Idrees, J
    Al Tamimi, JI
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 799 (01): : 103 - 109
  • [20] Determination of clarithromycin in human plasma by liquid chromatography-electrospray ionization tandem mass spectrometry
    Jiang, Yao
    Wang, Jiang
    Li, Hao
    Wang, Yingwu
    Gu, Jingkai
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2007, 43 (04) : 1460 - 1464