Single-shot Talbot-Lau x-ray dark-field imaging of a porcine lung applying the moire imaging approach

被引:6
作者
Seifert, Maria [1 ]
Ludwig, Veronika [1 ]
Gallersdoerfer, Michael [1 ]
Hauke, Christian [1 ,2 ]
Hellbach, Katharina [3 ]
Horn, Florian [1 ]
Pelzer, Georg [1 ]
Radicke, Marcus [2 ]
Rieger, Jens [1 ]
Sutter, Sven-Martin [2 ]
Michel, Thilo [1 ]
Anton, Gisela [1 ]
机构
[1] Friedrich Alexander Univ Erlangen Nurnberg FAU, Erlangen Ctr Astroparticle Phys, D-91058 Erlangen, Germany
[2] Siemens Healthcare GmbH, D-91301 Forchheim, Germany
[3] Ludwig Maximilians Univ Munchen, Dept Radiol, Univ Hosp, D-81377 Munich, Germany
关键词
x ray imaging; phase contrast; dark field; Talbot-Lau; moire imaging; interferometric imaging; lung imaging; WHITE SYNCHROTRON-RADIATION; PHASE-CONTRAST; GRATING INTERFEROMETER; PULMONARY-EMPHYSEMA; TOMOGRAPHY; DIAGNOSIS; RADIOGRAPHY; SIZE; CT; EXERCISE;
D O I
10.1088/1361-6560/aadafe
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Talbot-Lau x-ray imaging provides additionally to the conventional attenuation image, two further images: the differential phase-contrast image which is especially sensitive to differences in refractive properties and the dark-field image which is showing the x-ray scattering properties of the object. Thus, in the dark-field image sub-pixeled object information can be observed. As it has been shown in recent studies, this is of special interest for lung imaging. Changes in the alveoli structure, which are in the size of one detector pixel, can be seen in the dark-field images. A fast acquisition process is crucial to avoid motion artifacts due to heartbeat and breathing of the patient. Using moire imaging the images can be acquired with a single-shot exposure. Nevertheless, the spatial resolution is reduced compared to the phase-stepping acquisition. We evaluate the results of both imaging techniques towards their feasibility in clinical routine. Furthermore, we analyse the influence of artificial linear object movement on the image quality, in order to simulate the heartbeat of a patient.
引用
收藏
页数:13
相关论文
共 44 条
  • [1] Amidror I, 2009, COMPUT IMAGING VIS, V38, P1
  • [2] Laboratory-based X-ray phase-imaging scanner using Talbot-Lau interferometer for non-destructive testing
    Bachche, Shivaji
    Nonoguchi, Masahiro
    Kato, Koichi
    Kageyama, Masashi
    Koike, Takafumi
    Kuribayashi, Masaru
    Momose, Atsushi
    [J]. SCIENTIFIC REPORTS, 2017, 7
  • [3] In-vivo dark-field and phase-contrast x-ray imaging
    Bech, M.
    Tapfer, A.
    Velroyen, A.
    Yaroshenko, A.
    Pauwels, B.
    Hostens, J.
    Bruyndonckx, P.
    Sasov, A.
    Pfeiffer, F.
    [J]. SCIENTIFIC REPORTS, 2013, 3
  • [4] A grating-based single-shot x-ray phase contrast and diffraction method for in vivo imaging
    Bennett, Eric E.
    Kopace, Rael
    Stein, Ashley F.
    Wen, Han
    [J]. MEDICAL PHYSICS, 2010, 37 (11) : 6047 - 6054
  • [5] Multicontrast x-ray computed tomography imaging using Talbot-Lau interferometry without phase stepping
    Bevins, Nicholas
    Zambelli, Joseph
    Li, Ke
    Qi, Zhihua
    Chen, Guang-Hong
    [J]. MEDICAL PHYSICS, 2012, 39 (01) : 424 - 428
  • [6] Artificial thorax for MR imaging studies in porcine heart-lung preparations
    Biederer, J
    Heller, M
    [J]. RADIOLOGY, 2003, 226 (01) : 250 - 255
  • [7] BEHAVIOR OF STROKE VOLUME AT REST AND DURING EXERCISE IN HUMAN BEINGS
    CHAPMAN, CB
    FISHER, JN
    SPROULE, BJ
    [J]. JOURNAL OF CLINICAL INVESTIGATION, 1960, 39 (08) : 1208 - 1213
  • [8] NEW THEORETICAL AND EXPERIMENTAL RESULTS IN FRESNEL OPTICS WITH APPLICATIONS TO MATTER-WAVE AND X-RAY INTERFEROMETRY
    CLAUSER, JF
    REINSCH, MW
    [J]. APPLIED PHYSICS B-PHOTOPHYSICS AND LASER CHEMISTRY, 1992, 54 (05): : 380 - 395
  • [9] HUMAN CIRCADIAN-RHYTHMS IN RESTING AND EXERCISE PULSE RATES
    COHEN, CJ
    MUEHL, GE
    [J]. ERGONOMICS, 1977, 20 (05) : 475 - 479
  • [10] QUANTIFICATION OF PNEUMOTHORAX SIZE ON CHEST RADIOGRAPHS USING INTERPLEURAL DISTANCES - REGRESSION-ANALYSIS BASED ON VOLUME MEASUREMENTS FROM HELICAL CT
    COLLINS, CD
    LOPEZ, A
    MATHIE, A
    WOOD, V
    JACKSON, JE
    RODDIE, ME
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 165 (05) : 1127 - 1130