Measurements and modeling of long range 3He diffusion in the lung using a "slice-washout" method

被引:16
作者
Fichele, S [1 ]
Paley, MNJ [1 ]
Woodhouse, N [1 ]
Griffiths, PD [1 ]
van Beek, EJR [1 ]
Wild, JM [1 ]
机构
[1] Univ Sheffield, Royal Hallamshire Hosp, Acad Unit Radiol, Sheffield S10 2JF, S Yorkshire, England
关键词
helium; hyper-polarized; diffusion; ADC; PGSE;
D O I
10.1016/j.jmr.2004.12.011
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In healthy lung tissue, pulsed-gradient-spin-echo (PGSE) methods reveal apparent diffusion coefficients (ADC) of the order 0.20 cm(2) s(-1): for diffusion times of approximate to 2 ms. For these short diffusion times the ADC is only sensitive to structures approximately (2Dt)(1/2) approximate to 0.6 mm in size. Recent work, using magnetic tagging of the longitudinal magnetization has revealed much smaller ADC values for longer length scales. In this work, the in vivo ADC from within the air-spaces, was measured using a new technique. The signal from a series of images was analyzed from a slice that was repeatedly imaged. Diffusion tends to "top-up" the non-renewable polarization within the slice, which leads to a non-exponential decay in image signal. Image data were compared to ID finite-difference simulations of diffusion to calculate a long range ADC value. The results yield values of the order 0.034 cm(2) s(-1), which are nearly an order of magnitude smaller than those reported by PGSE measurements at shorter diffusion times. (c) 2005 Elsevier Inc. All rights reserved.
引用
收藏
页码:28 / 33
页数:6
相关论文
共 26 条
  • [1] In vivo NMR of hyperpolarized 3He in the human lung at very low magnetic fields
    Bidinosti, CP
    Choukeife, J
    Nacher, PJ
    Tastevin, G
    [J]. JOURNAL OF MAGNETIC RESONANCE, 2003, 162 (01) : 122 - 132
  • [2] CALLAGHAN P, 1991, PRINICIPLES NUCL MAG
  • [3] Biexponential diffusion attenuation in the rat spinal cord: Computer simulations based on anatomic images of axonal architecture
    Chin, CL
    Wehrli, FW
    Hwang, SN
    Takahashi, M
    Hackney, DB
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (03) : 455 - 460
  • [4] Crank J., 1979, MATH DIFFUSION
  • [5] Quantification of regional intrapulmonary oxygen partial pressure evolution during apnea by 3He MRI
    Deninger, AJ
    Eberle, B
    Ebert, M
    Grossmann, T
    Heil, W
    Kauczor, HU
    Lauer, L
    Markstaller, K
    Otten, E
    Schmiedeskamp, J
    Schreiber, W
    Surkau, R
    Thelen, M
    Weiler, N
    [J]. JOURNAL OF MAGNETIC RESONANCE, 1999, 141 (02) : 207 - 216
  • [6] Investigating 3He diffusion NMR in the lungs using finite difference simulations and in vivo PGSE experiments
    Fichele, S
    Paley, MNJ
    Woodhouse, N
    Griffiths, PD
    van Beek, EJR
    Wild, JM
    [J]. JOURNAL OF MAGNETIC RESONANCE, 2004, 167 (01) : 1 - 11
  • [7] Predictions of pulsed field gradient NMR echo-decays for molecules diffusing in various restrictive geometries.: Simulations of diffusion propagators based on a finite element method
    Hagslätt, H
    Jönsson, B
    Nydén, M
    Söderman, O
    [J]. JOURNAL OF MAGNETIC RESONANCE, 2003, 161 (02) : 138 - 147
  • [8] Pulmonary ventilation imaged by magnetic resonance: at the doorstep of clinical application
    Kauczor, HU
    Chen, XJ
    van Beek, EJR
    Schreiber, WG
    [J]. EUROPEAN RESPIRATORY JOURNAL, 2001, 17 (05) : 1008 - 1023
  • [9] DETERMINATION OF TEMPERATURE DEPENDENCE OF GASEOUS DIFFUSION-COEFFICIENTS USING GAS-CHROMATOGRAPHIC APPARATUS
    LINER, JC
    WEISSMAN, S
    [J]. JOURNAL OF CHEMICAL PHYSICS, 1972, 56 (05) : 2288 - &
  • [10] LUMB A, 2000, APPL RESP PHYSL