Bringing Light into Darkness-Comparison of Different Personal Dosimeters for Assessment of Solar Ultraviolet Exposure

被引:6
作者
Strehl, Claudine [1 ]
Heepenstrick, Timo [1 ]
Knuschke, Peter [2 ]
Wittlich, Marc [3 ]
机构
[1] Inst Occupat Safety & Hlth German Social Accid In, Dept Ergon Phys Environm Factors, D-53757 St Augustin, Germany
[2] Tech Univ Dresden, Fac Med, Dept Dermatol, D-01307 Dresden, Germany
[3] German Social Accid Insurance, Dept Accid Prevent Digitalisat Technol, Inst Occupat Safety & Hlth, D-53757 St Augustin, Germany
关键词
personal dosimetry; UV radiation; intercalibration; UV-RADIATION; POLYSULFONE FILM; SPORE DOSIMETRY; VALENCIA; ERYTHEMA; MODEL; BODY;
D O I
10.3390/ijerph18179071
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
(1) Measuring personal exposure to solar ultraviolet radiation (UVR) poses a major challenges for researchers. Often, the study design determines the measuring devices that can be used, be it the duration of measurements or size restrictions on different body parts. It is therefore of great importance that measuring devices produce comparable results despite technical differences and modes of operation. Particularly when measurement results from different studies dealing with personal UV exposure are to be compared with each other, the need for intercomparability and intercalibration factors between different measurement systems becomes significant. (2) Three commonly used dosimeter types-(polysulphone film (PSF), biological, and electronic dosimeters)-were selected to perform intercalibration measurements. They differ in measurement principle and sensitivity, measurement accuracy, and susceptibility to inaccuracies. The aim was to derive intercalibration factors for these dosimeter types. (3) While a calibration factor between PSF and electronic dosimeters of about 1.3 could be derived for direct irradiation of the dosimeters, this was not the case for larger angles of incidence of solar radiation with increasing fractions of diffuse irradiation. Electronic dosimeters show small standard deviation across all measurements. For biological dosimeters, no intercalibration factor could be found with respect to PSF and electronic dosimeters. In a use case, the relation between steady-state measurements and personal measurements was studied. On average, persons acquired only a small fraction of the ambient radiation.
引用
收藏
页数:13
相关论文
共 56 条
[51]   The wrist is a reliable body site for personal dosimetry of ultraviolet radiation [J].
Thieden, E ;
Ågren, MS ;
Wulf, HC .
PHOTODERMATOLOGY PHOTOIMMUNOLOGY & PHOTOMEDICINE, 2000, 16 (02) :57-61
[52]   A general model to predict individual exposure to solar UV by using ambient irradiance data [J].
Vernez, David ;
Milon, Antoine ;
Vuilleumier, Laurent ;
Bulliard, Jean-Luc ;
Koechlin, Alice ;
Boniol, Mathieu ;
Dore, Jean F. .
JOURNAL OF EXPOSURE SCIENCE AND ENVIRONMENTAL EPIDEMIOLOGY, 2015, 25 (01) :113-118
[53]   Measurements of Personal UV Exposure on Different Parts of the Body During Various Activities [J].
Weihs, Philipp ;
Schmalwieser, Alois ;
Reinisch, Corinna ;
Meraner, Elisabeth ;
Walisch, Silvia ;
Harald, Maier .
PHOTOCHEMISTRY AND PHOTOBIOLOGY, 2013, 89 (04) :1004-1007
[54]  
Wittlich, 2021, HAUTKREBS DURCH NATU
[55]   An approximation of occupational lifetime UVR exposure: algorithm for retrospective assessment and current measurements [J].
Wittlich, M. ;
Westerhausen, S. ;
Kleinespel, P. ;
Rifer, G. ;
Stoeppelmann, W. .
JOURNAL OF THE EUROPEAN ACADEMY OF DERMATOLOGY AND VENEREOLOGY, 2016, 30 :27-33
[56]   Solar Ultraviolet Radiation Risk Estimates-A Comparison of Different Action Spectra and Detector Responsivities [J].
Zolzer, Friedo ;
Bauer, Stefan .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2021, 18 (09)