novel nanocomposite based on gold nanoparticles loaded on acetylene black for electrochemical sensing of the anticancer drug topotecan in the presence of high concentration of uric acid

被引:25
作者
Ibrahim, Mohamed [1 ]
Ibrahim, Hossieny [2 ]
Almandil, Noor B. [1 ]
Kawde, Abdel-Nasser [3 ]
机构
[1] Imam Abdulrahman Bin Faisal Univ, Inst Res & Med Consultat, Dept Clin Pharm Res, POB 1982, Dammam 31441, Saudi Arabia
[2] Assiut Univ, Fac Sci, Dept Chem, Assiut, Egypt
[3] King Fahd Univ Petr & Minerals, Coll Sci, Dept Chem, Dhahran 31261, Saudi Arabia
关键词
Topotecan; Acetylene black; Gold nanoparticles; Modified electrode; Voltammetric nanosensor; Drug analysis; LIQUID-CHROMATOGRAPHY; WHOLE-BLOOD; SENSOR; CANCER; PLASMA; DNA; ELECTRODES; FILM;
D O I
10.1016/j.jelechem.2018.07.031
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this study, a new voltammetric nanosensor was constructed by the decoration of acetylene black (AB) with gold nanoparticles (AuNPs) using glassy carbon paste (GCP) as a cross linker (nano-AB-AuNPs/GCPE) for determination of anticancer topotecan (TPT) drug. Moreover, from the response characteristics of cyclic voltammetry (CV) and square wave voltammetry (SWV), it was observed that TPT could be effectively accumulated at nano-AB-AuNPs/GCPE and resulted in a sensitive anodic peak current in PBS of pH 6.0. The surface area, electrical conductivity and catalytic performance of the modified electrode improved on account of the formation of nano-AB-AuNPs materials, thereby enhancing the sensitivity of the nanosensor. Under optimal conditions, a novel electrochemical method based on the nano-AB-AuNPs/GCPE sensor with high selectivity, high sensitivity and high anti-interference ability was developed for the determination of TPT. Furthermore, the electrochemical oxidation of TPT reveals an excellent linearity in the range of 1.99 x 10(-9) to 6.71 x 10(-7) M of TPT with a detection limit of 1.64 x 10(-11) M (6.91 x 10(-3) ng/mL). The TPT as a preconcentration agent showed chemical selectivity, so, the nanosensor was successfully applied for the determination of TPT in the presence of high concentrations of uric acid. Moreover, the method was employed efficiently to detect TPT in blood serum and urine samples, with satisfactory recoveries ranging from 98.16% to 100.76%.
引用
收藏
页码:22 / 31
页数:10
相关论文
共 36 条
[1]   An amplified platform nanostructure sensor for the analysis of epirubicin in the presence of topotecan as two important chemotherapy drugs for breast cancer therapy [J].
Alavi-Tabari, Seyed A. R. ;
Khalilzadeh, Mohammad A. ;
Karimi-Maleh, Hassan ;
Zareyee, Daryoush .
NEW JOURNAL OF CHEMISTRY, 2018, 42 (05) :3828-3832
[2]   Quantification of topotecan by liquid chromatography-mass spectrometry (LC-MS). Application to intestinal transport using rat everted gut sacs [J].
Arellano, Cecile ;
Gandia, Peggy ;
Bettuing, Laure ;
Woodley, John ;
Chatelut, Etienne .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2010, 878 (7-8) :645-652
[3]   Topotecan exposure estimation in pediatric acute myeloid leukemia supported by LC-MS-based drug monitoring and pharmacokinetic analysis [J].
Baczek, Tomasz ;
Konieczna, Lucyna ;
Belka, Mariusz ;
Maciejka-Kapuscinska, Lucyna ;
Wisniewski, Jakub ;
Niedzwiecki, Maciej ;
Balcerska, Anna ;
Adamkiewicz-Drozynska, Elzbieta ;
Wachowiak, Jacek .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2012, 70 :330-336
[4]  
Baraket A., 2014, Sensors Transducers, V27, P15
[5]   A Sensitive Electrochemical DNA Biosensor for Anticancer Drug Topotecan Based on Graphene Carbon Paste Electrode [J].
Beitollahi, Hadi ;
Dehghannoudeh, Gholamreza ;
Moghaddam, Hadi Mahmoudi ;
Forootanfar, Hamid .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2017, 164 (12) :II812-II817
[6]   Fluorescence detection of the anticancer drug topotecan in plasma and whole blood by two-photon excitation [J].
Burke, TG ;
Malak, H ;
Gryczynski, I ;
Mi, ZH ;
Lakowicz, JR .
ANALYTICAL BIOCHEMISTRY, 1996, 242 (02) :266-270
[7]   High-performance liquid chromatographic assay for the determination of total and free topotecan in the presence and absence of anti-topotecan antibodies in mouse plasma [J].
Chen, J ;
Balthasar, JP .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 816 (1-2) :183-192
[8]   Electrochemical detection of anticancer drug topotecan using nano-acetylene black film [J].
Cheng, Qin ;
Du, Yu ;
Wu, Kangbing ;
Chen, Jianwei ;
Zhou, Yikai .
COLLOIDS AND SURFACES B-BIOINTERFACES, 2011, 84 (01) :135-139
[9]   Electrochemical investigation of the interaction between topotecan and DNA at disposable graphite electrodes [J].
Congur, Gulsah ;
Erdem, Arzum ;
Mese, Fehmi .
BIOELECTROCHEMISTRY, 2015, 102 :21-28
[10]   Stability and compatibility of topotecan hydrochloride for injection with common infusion solutions and containers [J].
Craig, SB ;
Bhatt, UH ;
Patel, K .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1997, 16 (02) :199-205