Study on Haemodynamic Response to Laryngoscopy and Intubation using McCOY and Macintosh Laryngoscopes: A Comparative Approach

被引:0
|
作者
Barish, M. [1 ]
机构
[1] Bharath Inst Higher Educ & Res, Sree Balaji Med Coll & Hosp, Dept Anaesthesiol Pain Med & Crit Care, Chennai, Tamil Nadu, India
关键词
Myocardial ischemia; cardiac rythym; laryngoscopy; McCOY; macintosh;
D O I
10.9734/JPRI/2021/v33i40A32251
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Introduction: Laryngoscopy and endotracheal intubation are known to cause increase in arterial blood pressure, heart rate and may be associated with various dysarythmias. This study is done to compare the hemodynamic changes with McCOY laryngoscope and Macintosh laryngoscope in 120 patients who were divided into 2 groups. Methods: A positive correlation has been demonstrated between force exerted at laryngoscopy and patients height, weight, body mass index (BMI) and presence of maxillary incisors but it was seen that effect of these factors on force exerted with the McCOY blade is not as important as with Macintosh blade. So this study was done to compare the hemodynamic response to laryngoscopy and intubation using McCOY and Macintosh laryngoscope in stress attenuation. Results: Maximum increase in heart rate from the baseline after laryngoscopy in group 2 and a least rise in heart rate from base line in group 1.Group 1 has 9 % increase in heart rate from basal value. Group 2 has 22 % increases in heart rate from basal value. Group 1 has 6 % increase Systolic BP from basal value Group 2 has 27 % increase in Systolic BP from basal value. Rise in Plasma adrenaline after laryngoscopy was not observed in Laryngoscopy with McCOY blade. Conclusion: McCOY laryngoscope produces significantly less in Hemodynamic parameters when compared with Macintosh blade.So this non-pharmacological intervention of McCOY blade can be utilized as a tool for obtunding hemodynamic responses to laryngoscopy and intubation
引用
收藏
页码:320 / 324
页数:5
相关论文
共 50 条
  • [1] Comparative evaluation of intubating conditions and hemodynamic response to laryngoscopy and intubation with McCoy and Macintosh laryngoscopes; a prospective randomized study
    Bansal, Sapna
    Bansal, Sachin
    Jaggy
    Kaur, Dhanwant
    Sharma, Seema
    Preet
    ANAESTHESIA PAIN & INTENSIVE CARE, 2018, 22 (02) : 193 - 198
  • [2] COMPARISON OF HEMODYNAMIC RESPONSE TO TRACHEAL INTUBATION WITH MACINTOSH AND MCCOY LARYNGOSCOPES
    Jitendra, Mukta
    Sharma, Sonal
    Katoch, Madan
    Gulati, Smriti
    Gupta, Heena
    JOURNAL OF EVOLUTION OF MEDICAL AND DENTAL SCIENCES-JEMDS, 2015, 4 (50): : 8676 - 8684
  • [3] A comparative study to evaluate the cervical spine movements during laryngoscopy using Macintosh and Airtraq laryngoscopes
    Kaur, Kiranpreet
    Raja, Rameez
    Kumar, Prashant
    Singh, Roop
    Vashishth, Sumedha
    Singh, Harshil D.
    Bhardwaj, Mamta
    Singhal, Suresh K.
    JOURNAL OF ANAESTHESIOLOGY CLINICAL PHARMACOLOGY, 2024, 40 (01) : 101 - 107
  • [4] A COMPARATIVE STUDY OF DEXMEDETOMIDINE AND CLONIDINE TO ATTENUATE HAEMODYNAMIC RESPONSE DURING LARYNGOSCOPY AND INTUBATION
    Kaur, Balwinder
    Bariar, Hardeep
    Kumar, Parmod
    Garg, Sahil
    Sharma, Charu
    Kumar, Lalit
    JOURNAL OF EVOLUTION OF MEDICAL AND DENTAL SCIENCES-JEMDS, 2018, 7 (19): : 2404 - 2409
  • [5] Comparison of glottic view and ease of orotracheal intubation with Macintosh and McCoy laryngoscopes in anaesthetized adult patients
    Duggappa, Arun Kumar Handigodu
    Muhamed, Shiyad
    Mathew, Shaji
    Pujari, Satyanarayana Kuruba
    Prabhu, Manjunath
    Navada, Jayanth
    SRI LANKAN JOURNAL OF ANAESTHESIOLOGY, 2019, 27 (02): : 151 - 156
  • [6] Hemodynamic Response to Laryngoscopy and Intubation Using McCoy Laryngoscope: A Descriptive Cross-sectional Study
    Lakhe, Gajal
    Pradhan, Suresh
    Dhakal, Santosh
    JOURNAL OF NEPAL MEDICAL ASSOCIATION, 2021, 59 (238) : 554 - 557
  • [7] COMPARATIVE STUDY ON THREE DOSES OF ESMOLOL TO ATTENUATE THE HAEMODYNAMIC STRESS RESPONSE DURING LARYNGOSCOPY AND ENDOTRACHEAL INTUBATION
    Raghavan, L.
    Basker, N.
    JOURNAL OF EVOLUTION OF MEDICAL AND DENTAL SCIENCES-JEMDS, 2016, 5 (49): : 3216 - 3221
  • [8] ATTENUATION OF HAEMODYNAMIC RESPONSE TO LARYNGOSCOPY & INTUBATION- A COMPARATIVE STUDY BETWEEN ORAL GABAPENTIN AND ORAL CLONIDINE
    Saikia, Arunima
    Tayung, Raju Prasad
    Saha, Maumita
    JOURNAL OF EVOLUTION OF MEDICAL AND DENTAL SCIENCES-JEMDS, 2019, 8 (26): : 2119 - 2125
  • [9] COMPARATIVE STUDY BETWEEN INTRAVENOUS DEXMEDETOMIDINE AND ESMOLOL IN ATTENUATION OF HAEMODYNAMIC STRESS RESPONSE DURING ENDOTRACHEAL INTUBATION AND LARYNGOSCOPY
    Bhutia, Tshering P.
    Mehta, Purvi J.
    Sugadev
    JOURNAL OF EVOLUTION OF MEDICAL AND DENTAL SCIENCES-JEMDS, 2018, 7 (44): : 4770 - 4776
  • [10] ATTENUATION OF HAEMODYNAMIC RESPONSE TO LARYNGOSCOPY AND ENDOTRACHEAL INTUBATION USING INTRA-ORAL IVABRADINE: A CLINICAL STUDY
    Raghuram, C. G.
    Singh, Deepraj
    Kabra, Aditya Vikram
    JOURNAL OF EVOLUTION OF MEDICAL AND DENTAL SCIENCES-JEMDS, 2014, 3 (39): : 9944 - 9955