Determination of chemical oxygen demand by a flow injection method based on microwave digestion and chromium speciation coupled to inductively coupled plasma optical emission spectrometry

被引:21
作者
Almeida, Cesar A. [1 ,2 ,3 ,4 ]
Gonzalez, Patricia [1 ,2 ]
Mallea, Miguel [1 ,2 ]
Martinez, Luis D. [1 ,2 ,3 ,4 ]
Gil, Raul A. [1 ,2 ,3 ,4 ]
机构
[1] Univ Nacl San Luis, Fac Quim Bioquim & Farm, Area Quim Analit, RA-5700 Chacabuco, San Luis, Argentina
[2] Univ Nacl San Luis, Fac Quim Bioquim & Farm, Area Quim Analit, RA-5700 Pedernera, San Luis, Argentina
[3] INQUISAL UNSL CONICET, Inst Quim San Luis, Chacabuco, San Luis, Argentina
[4] INQUISAL UNSL CONICET, Inst Quim San Luis, Pedernera, San Luis, Argentina
关键词
Chemical oxygen demand; On-line microwave digestion; Solid phase extraction; USN-ICP-OES; ATOMIC-ABSORPTION-SPECTROMETRY; ONLINE PRECONCENTRATION; WATER SAMPLES; ION-EXCHANGE; CR(III); CR(VI); EXTRACTION; METALS; SYSTEM; COLUMN;
D O I
10.1016/j.talanta.2012.04.030
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The present paper evaluates the applicability of a new FIA system for COD determination. The new system, flow injection microwave solid phase extraction by means of activated carbon (FI-MW-SPE), consists of a digestion circuit, placed in a home MW oven, coupled to an ICP-OES spectrophotometer. Doehlert experimental design was used to speed up the optimization of different experimental variables studied for assisted digestion methods. The method provided a high throughput of about 18 samples h(-1). To assess the accuracy of analytical methods linear regression, elliptic joint confidence region (EJCR) was used. A large linear range of 2.78-850 mg O-2 L-1 with an excellent detection limit of 0.94 mg O-2 L-1 was obtained. The interference by high chloride concentration was studied, and values below 3000 mg Cl- ions L-1, allowed the estimation of COD load without any masking agents. COD values for various types of wastewater samples were correlated with those obtained by standard manual methods. Moreover, interferences due to matrix nature are absent; since matrix is washed out of the column before Cr (III) is eluted. This method reduces the time, reagent volume, hazardous emission, external contamination, with a good reproducibility and accuracy. (C) 2012 Published by Elsevier B.V.
引用
收藏
页码:273 / 278
页数:6
相关论文
共 26 条
[1]   Flame atomic absorption spectrometric determination of chromium(VI) by on-line preconcentration system using a PTFE packed column [J].
Anthemidis, AN ;
Zachariadis, GA ;
Kougoulis, JS ;
Stratis, JA .
TALANTA, 2002, 57 (01) :15-22
[2]  
Baird R.B., 2005, Standard methods for the examination of water and wastewater
[3]   Evaluation of chelating ion-exchange resins for separating Cr(III) from industrial effluents [J].
Cavaco, Sofia A. ;
Fernandes, Sandra ;
Augusto, Catia M. ;
Quina, Margarida J. ;
Gando-Ferreira, Licinio M. .
JOURNAL OF HAZARDOUS MATERIALS, 2009, 169 (1-3) :516-523
[4]   Development of a new system for the speciation of chromium in natural waters and human urine samples by combining ion exchange and ETA-AAS [J].
Cordero, MTS ;
Alonso, EIV ;
de Torres, AG ;
Pavón, JMC .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2004, 19 (03) :398-403
[5]   KINETIC APPROACH TO THE MEASUREMENT OF CHEMICAL OXYGEN-DEMAND WITH AN AUTOMATED MICRO BATCH ANALYZER [J].
DASGUPTA, PK ;
PETERSEN, K .
ANALYTICAL CHEMISTRY, 1990, 62 (04) :395-402
[6]  
Davis M.L., 1998, Introduction to Environmental Engineering, VThird
[7]   EVALUATION OF MICROWAVE DIGESTION FOR CHEMICAL OXYGEN-DEMAND DETERMINATION [J].
DELVALLE, M ;
POCH, M ;
ALONSO, J ;
BARTROLI, J .
ENVIRONMENTAL TECHNOLOGY, 1990, 11 (12) :1087-1092
[8]   Doehlert matrix: a chemometric tool for analytical chemistry - review [J].
Ferreira, SLC ;
dos Santos, WNL ;
Quintella, CM ;
Neto, BB ;
Bosque-Sendra, JA .
TALANTA, 2004, 63 (04) :1061-1067
[9]   Application of Doehlert designs in the optimization of experimental variables associated with the simultaneous solvent extraction of several metals [J].
Gazquez, D ;
Sanchez-Vinas, M ;
Bagur, MG ;
Garcia, G .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1998, 13 (02) :105-108
[10]   On-line preconcentration and determination of chromium in parenteral solutions by inductively coupled plasma optical emission spectrometry [J].
Gil, RA ;
Cerutti, S ;
Gásquez, JA ;
Olsina, RA ;
Martinez, LD .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2005, 60 (04) :531-535