Accuracy of linear temporomandibular joint measurements with cone beam computed tomography and digital cephalometric radiography

被引:238
作者
Hilgers, ML
Scarfe, WC
Scheetz, JP
Farman, AG
机构
[1] Univ Louisville, Sch Dent, Dept Surg & Hosp Dent, Louisville, KY 40292 USA
[2] Univ Louisville, Sch Dent, Dept Orthodont & Pediat Dent, Louisville, KY 40292 USA
[3] Univ Louisville, Sch Dent, Dept Diagnost Sci Prosthodont & Restorat Dent, Louisville, KY 40292 USA
关键词
D O I
10.1016/j.ajodo.2005.08.034
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: Cone beam computed tomography (CBCT) is making headway into imaging for orthodontics. The purpose of this study was to define CBCT multi-planar reformatted projections for temporomandibular joint (TMJ) examination and compare the accuracy of linear measurements of the TMJ and related structures from these projections with similar measurements made with conventional cephalograms and with the anatomic truth. Methods: Linear dimensions between 11 anatomical sites were measured with a digital callper to assess the anatomic truth for 25 dry human skulls. The skulls were imaged with iCAT (Xoran Technologies, Ann Arbor, Mich/Imaging Sciences International, Hatfield, Pa) CBCT, and cephalograms were made in all 3 orthogonal planes (lateral cephalometric [LC], posteroanterior [PA], and submentovertex [SMV]) acquired with photostimulable phosphor plates. Linear measurements were made on 7 custom CBCT reconstructions and the digital cephalograms. Modality means and the natural log of the standard deviations were compared post hoc against the actual dimensions by using analysis of variance with the Dunnett t test. Significance was set at P <.05. Results: All CIBCT measurements were accurate; however, 3 of 5 LC measurements, 4 of 5 PA measurements, and 4 of 6 SMV measurements varied significantly from the truth. Intraobserver CIBCT measurements were highly reliable compared with anatomic truth and significantly more reliable than measurements made from LC, PA, and SMV images. Conclusions: Custom oblique multi-planar reformatted reconstructions with iCAT CIBCT provide accurate and reliable linear measurements of mandibular and TMJ dimensions.
引用
收藏
页码:803 / 811
页数:9
相关论文
共 35 条
[1]  
Aboudara C A, 2003, Orthod Craniofac Res, V6 Suppl 1, P173, DOI 10.1034/j.1600-0544.2003.253.x
[2]   Using a flat-panel detector in high resolution cone beam CT for dental imaging [J].
Baba, R ;
Ueda, K ;
Okabe, M .
DENTOMAXILLOFACIAL RADIOLOGY, 2004, 33 (05) :285-290
[3]  
Baumrind S, 2003, Orthod Craniofac Res, V6 Suppl 1, P132, DOI 10.1034/j.1600-0544.2003.246.x
[4]  
BEASON R, 2004, J DENT RES, V83, P1938
[5]  
Bianchi S., 2001, DENTOMAXILLOFAC RAD, V30, pS28
[6]   Imaging of the temporomandibular joint - A position paper of the American Academy of Oral and Maxillofacial Radiology [J].
Brooks, SL ;
Brand, JW ;
Gibbs, SJ ;
Hollender, L ;
Lurie, AG ;
Omnell, KA ;
Westesson, PL ;
White, SC .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 1997, 83 (05) :609-618
[7]   Prospective study of posttreatment changes in the temporomandibular joint [J].
Carlton, KL ;
Nanda, RS .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2002, 122 (05) :486-490
[8]  
Danforth Robert A, 2003, J Calif Dent Assoc, V31, P817
[9]  
Danforth Robert A, 2003, J Calif Dent Assoc, V31, P847
[10]  
DIXON D, 1995, SEMINARS ORTHODONTIC, P207