Portable electrophoresis titration chip model for sensing of uric acid in urine and blood by moving reaction boundary

被引:36
作者
Khan, Muhammad Idrees [1 ,2 ]
Zhang, Qiang [1 ,2 ]
Wang, Yuxin [3 ]
Saud, Shah [1 ,2 ]
Liu, Weiwen [1 ,2 ]
Liu, Shaorong [4 ]
Kong, Hao [1 ,2 ]
Wang, Cunhuai [1 ,2 ]
Uzzaman, Asad [1 ,2 ]
Xiao, Hua [2 ]
Fan, Liu-Yin [1 ]
Cao, Cheng-Xi [1 ,2 ]
机构
[1] Shanghai Jiao Tong Univ, Sch Elect Informat & Elect Engn, Dept Instrument Sci & Engn, Shanghai 200240, Peoples R China
[2] Shanghai Jiao Tong Univ, Sch Life Sci & Biotechnol, State Key Lab Microbial Metab, Shanghai 200240, Peoples R China
[3] Shanghai Jiao Tong Univ, Sch Phys & Astron, Shanghai 200240, Peoples R China
[4] Univ Oklahoma, Dept Chem & Biochem, Norman, OK 73019 USA
基金
中国国家自然科学基金;
关键词
Chip; Electrophoresis titration; Moving reaction boundary; Point of care testing; Uric acid; ASCORBIC-ACID; SERUM; DOPAMINE; DISEASE; GLUCOSE;
D O I
10.1016/j.snb.2019.01.098
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Assays of uric acid (UA) in human urine and blood are of great significance to clinic diagnoses of many diseases, such as gout, renal failure, and hyperuricemia. Portable and visual quantification method, however, has been rarely developed for POCT detection of UA in urine and blood samples. In this work, we developed the electrophoresis titration (ET) model, the relevant sensing method and the portable chip device for portable and visual detection of UA in both urine and blood based on moving reaction boundary (MRB). In the model, uricase catalyzes UA in the anode well to allantoin, producing hydrogen peroxide, which oxidizes leucocrystal violet dye without charge to crystal violet (CV+) with one positive charge. Under an electric field, a MRB was created between the violet CV+ moving from the anode well into the channel and the alkaline sodium acetate in channel, resulting in an ET sensing. The model indicated that the distance of MRB under given conditions was as a function of UA content, implying an extraordinary simple sensing for UA. Based on the MRB-ET model, a series of experiments were conducted. The results evidently validated the model and method of ET-MRB. The experiments not only demonstrated the high facility and portability of MRB-ET model, but also showed the visuality, selectivity and rapidity. In addition, the experiments revealed the fair sensitivity (< 0.1 mM), linearity (0.1-4.0 mM, r(2) = 0.9948), recovery (85%-106%) and stability (RSD 3.8-7.1%). Finally, the developed method was successfully used for the determination of UA both in urine and blood. All these results manifested the simple, portable and visual sensing of UA in human body fluid samples, and implied the potential of MRB-ET method to real POCT assay of UA in urine and blood samples.
引用
收藏
页码:9 / 15
页数:7
相关论文
共 26 条
[1]   A biosensor based on urate oxidase-peroxidase coupled enzyme system for uric acid determination in urine [J].
Akyilmaz, E ;
Sezgintürk, MK ;
Dinçkaya, E .
TALANTA, 2003, 61 (02) :73-79
[2]   A simple and sensitive fluorescence based biosensor for the determination of uric acid using H2O2-sensitive quantum dots/dual enzymes [J].
Azmi, Nur Ellina ;
Ramli, Noor Izaanin ;
Abdullah, Jaafar ;
Hamid, Mohammad Azmi Abdul ;
Sidek, Hamidah ;
Abd Rahman, Samsulida ;
Ariffin, Nurhayati ;
Yusof, Nor Azah .
BIOSENSORS & BIOELECTRONICS, 2015, 67 :129-133
[3]   Serum uric acid and cardiovascular disease: Recent developments, and where do they leave us? [J].
Baker, JF ;
Krishnan, E ;
Chen, L ;
Schumacher, HR .
AMERICAN JOURNAL OF MEDICINE, 2005, 118 (08) :816-826
[4]   Stacking ionizable analytes in a sample matrix with high salt by a transient moving chemical reaction boundary, method in capillary zone electrophoresis [J].
Cao, CX ;
He, YZ ;
Li, M ;
Qian, YT ;
Gao, MF ;
Ge, LH ;
Zhou, SL ;
Yang, L ;
Qu, QS .
ANALYTICAL CHEMISTRY, 2002, 74 (16) :4167-4174
[5]   iPhone-imaged and cell-powered electrophoresis titration chip for the alkaline phosphatase assay in serum by the moving reaction boundary [J].
Cao, Xin-yu ;
Kong, Fan-zhi ;
Zhang, Qiang ;
Liu, Wei-wen ;
Liu, Xiao-ping ;
Li, Guo-qing ;
Zhong, Ran ;
Fan, Liu-yin ;
Xiao, Hua ;
Cao, Cheng-xi .
LAB ON A CHIP, 2018, 18 (12) :1758-1766
[6]   An amperometric uric acid biosensor based on multiwalled carbon nanotube-gold nanoparticle composite [J].
Chauhan, Nidhi ;
Pundir, Chandra Shekhar .
ANALYTICAL BIOCHEMISTRY, 2011, 413 (02) :97-103
[7]   A disposable single-use electrochemical sensor for the detection of uric acid in human whole blood [J].
Chen, JC ;
Chung, HH ;
Hsu, CT ;
Tsai, DM ;
Kumar, AS ;
Zen, JM .
SENSORS AND ACTUATORS B-CHEMICAL, 2005, 110 (02) :364-369
[8]   A review of enzymatic uric acid biosensors based on amperometric detection [J].
Erden, Pinar Esra ;
Kilic, Esma .
TALANTA, 2013, 107 :312-323
[9]   Accuracy of the HumaSensplus point-of-care uric acid meter using capillary blood obtained by fingertip puncture [J].
Fabre, Stephanie ;
Clerson, Pierre ;
Launay, Jean-Marie ;
Gautier, Jean-Francois ;
Vidal-Trecan, Tiphaine ;
Riveline, Jean-Pierre ;
Platt, Adam ;
Abrahamsson, Anna ;
Miner, Jeffrey N. ;
Hughes, Glen ;
Richette, Pascal ;
Bardin, Thomas .
ARTHRITIS RESEARCH & THERAPY, 2018, 20
[10]   Highly specific and sensitive non-enzymatic determination of uric acid in serum and urine by extended gate field effect transistor sensors [J].
Guan, Weihua ;
Duan, Xuexin ;
Reed, Mark A. .
BIOSENSORS & BIOELECTRONICS, 2014, 51 :225-231