Status of electrical tomography in industrial applications

被引:199
作者
York, T [1 ]
机构
[1] Univ Manchester, Inst Sci & Technol, Dept Elect Engn & Elect, Manchester M60 1QD, Lancs, England
关键词
D O I
10.1117/1.1377308
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The paper surveys the status of electrical tomography for industrial applications. For the present purposes this is considered to include "low" excitation frequencies, up to about 1 MHz, comprising resistance (electrical resistance tomography), capacitance (electrical capacitance tomography), inductance (electromagnetic tomography) and impedance (electrical impedance tomography) modalities. Introductory background material is followed by comparisons between the instruments that have emerged. Data processing is considered with emphasis on the trade-offs that are necessary in implementing algorithms for reconstructing images. Recent applications are tabulated and case studies are presented for six contrasting areas that illustrate significant progress towards industrial benefit. Some comparison is made with applications to medical tomography and a number of issues are identified for future research. (C) 2001 SPIE and IS&T.
引用
收藏
页码:608 / 619
页数:12
相关论文
共 47 条
[1]   Process tomography - the state of the art [J].
Beck, MS ;
Dyakowski, T ;
Williams, RA .
TRANSACTIONS OF THE INSTITUTE OF MEASUREMENT AND CONTROL, 1998, 20 (04) :163-177
[2]  
BEISSNER RE, 1999, REV PROGR QUANTITATI, V18, P469, DOI DOI 10.1007/978-1-4615-4791-4_59
[3]   Imaging with electricity: Report of the European Concerted Action on Impedance Tomography [J].
Boone, K ;
Barber, D ;
Brown, B .
JOURNAL OF MEDICAL ENGINEERING & TECHNOLOGY, 1997, 21 (06) :201-232
[4]  
BRECKON WR, 1991, RES NOTES MATH, P245
[5]   ACT3 - A HIGH-SPEED, HIGH-PRECISION ELECTRICAL-IMPEDANCE TOMOGRAPH [J].
COOK, RD ;
SAULNIER, GJ ;
GISSER, DG ;
GOBLE, JC ;
NEWELL, JC ;
ISAACSON, D .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1994, 41 (08) :713-722
[6]  
Deans S., 1983, RADON TRANSFORM SOME
[7]   TOMOGRAPHIC IMAGING OF INDUSTRIAL-PROCESS EQUIPMENT - TECHNIQUES AND APPLICATIONS [J].
DICKIN, FJ ;
HOYLE, BS ;
HUNT, A ;
HUANG, SM ;
ILYAS, O ;
LENN, C ;
WATERFALL, RC ;
WILLIAMS, RA ;
XIE, CG ;
BECK, MS .
IEE PROCEEDINGS-G CIRCUITS DEVICES AND SYSTEMS, 1992, 139 (01) :72-82
[8]   Industrial process tomography - Preface [J].
Dyakowski, T ;
Mann, R .
CHEMICAL ENGINEERING JOURNAL, 2000, 77 (1-2) :1-1
[9]   A CAPACITIVE SYSTEM FOR 3-DIMENSIONAL IMAGING OF FLUIDIZED-BEDS [J].
FASCHING, GE ;
SMITH, NS .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1991, 62 (09) :2243-2251
[10]   A multichannel continuously selectable multifrequency electrical impedance spectroscopy measurement system [J].
Hartov, A ;
Mazzarese, RA ;
Reiss, FR ;
Kerner, TE ;
Osterman, KS ;
Williams, DB ;
Paulsen, KD .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2000, 47 (01) :49-58