Three-dimensional determination of absorbed dose by spectrophotometric analysis of ferrous-sulphate agarose gel

被引:39
作者
Gambarini, G
Gomarasca, G
Marchesini, R
Pecci, A
Pirola, L
Tomatis, S
机构
[1] Univ Milan, Dipartimento Fis, I-20133 Milan, Italy
[2] Ist Nazl Fis Nucl, Milan, Italy
[3] Ist Nazl Studio & Cura Tumori, Milan, Italy
关键词
ferrous-sulphate agarose gel; 3-D imaging; phantoms; gel-dosimeter slices;
D O I
10.1016/S0168-9002(98)00975-9
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We describe a technique to obtain three-dimensional (3-D) imaging of an absorbed dose by optical transmittance measurements of phantoms composed by agarose gel in which a ferrous sulphate and xylenol orange solution are incorporated, The analysis of gel samples is performed by acquiring transmittance images with a system based on a CCD camera provided with an interference filter matching the optical absorption peak of interest. The proposed technique for 3-D measurements of an absorbed dose is based on the imaging of phantoms composed of sets of properly piled up gel slices. The slice thickness was optimized in order to obtain a good image contrast as well as a good in-depth spatial resolution. To test the technique, a phantom has been irradiated with a collimated gamma-beam and then analysed. Proper software was adapted in order to visualise the images of all slices and to attain the 2-D profiles of the dose absorbed by each slice. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:643 / 648
页数:6
相关论文
共 7 条
[1]   DIFFUSION IN FE(II/III) RADIATION-DOSIMETRY GELS MEASURED BY MAGNETIC-RESONANCE-IMAGING [J].
BALCOM, BJ ;
LEES, TJ ;
SHARP, AR ;
KULKARNI, NS ;
WAGNER, GS .
PHYSICS IN MEDICINE AND BIOLOGY, 1995, 40 (10) :1665-1676
[2]   DOSE-RESPONSE CURVE SLOPE IMPROVEMENT AND RESULT REPRODUCIBILITY OF FERROUS-SULFATE-DOPED GELS ANALYZED BY NMR IMAGING [J].
GAMBARINI, G ;
ARRIGONI, S ;
CANTONE, MC ;
MOLHO, N ;
FACCHIELLI, L ;
SICHIROLLO, AE .
PHYSICS IN MEDICINE AND BIOLOGY, 1994, 39 (04) :703-717
[3]   A SYSTEM FOR 3-D ABSORBED DOSE MEASUREMENTS WITH TISSUE-EQUIVALENCE FOR THERMAL-NEUTRONS [J].
GAMBARINI, G ;
ARRIGONI, S ;
BONARDI, M ;
CANTONE, MC ;
DEBARTOLO, D ;
DESIATI, S ;
FACCHIELLI, L ;
SICHIROLLO, AE .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 353 (1-3) :406-410
[4]   Fricke-infused agarose gel phantoms for NMR dosimetry in boron neutron capture therapy and proton therapy [J].
Gambarini, G ;
Birattari, C ;
Monti, D ;
Fumagalli, ML ;
Vai, A ;
Salvadori, P ;
Facchielli, L ;
Sichirollo, AE .
RADIATION PROTECTION DOSIMETRY, 1997, 70 (1-4) :571-575
[5]   Phantom dosimeters examined by NMR analysis: A promising technique for 3-D determination of absorbed dose [J].
Gambarini, G ;
Monti, D ;
Fumagalli, ML ;
Birattari, C ;
Salvadori, P .
APPLIED RADIATION AND ISOTOPES, 1997, 48 (10-12) :1477-1484
[6]   Measurement of the ferric diffusion coefficient in agarose and gelatine gels by utilization of the evolution of a radiation induced edge as reflected in relaxation rate images [J].
Pedersen, TV ;
Olsen, DR ;
Skretting, A .
PHYSICS IN MEDICINE AND BIOLOGY, 1997, 42 (08) :1575-1585
[7]   Chelator effect on ion diffusion in ferrous-sulfate-doped gelatin gel dosimeters as analyzed by MRI [J].
Rae, WID ;
Willemse, CA ;
Lotter, MG ;
Engelbrecht, JS ;
Swarts, JC .
MEDICAL PHYSICS, 1996, 23 (01) :15-23