Home blood pressure measurements associated with better blood pressure control: the J-HOME study

被引:23
作者
Obara, T. [2 ,3 ]
Ohkubo, T. [1 ,3 ]
Asayama, K. [3 ]
Metoki, H. [4 ]
Inoue, R. [3 ]
Kikuya, M. [2 ]
Kato, T. [2 ]
Tanaka, K. [1 ]
Hara, A. [2 ,3 ]
Hashimoto, J. [1 ,3 ]
Totsune, K. [2 ,3 ]
Imai, Y. [2 ,3 ]
机构
[1] Tohoku Univ, Grad Sch Pharmaceut Sci, Dept Planning Drug Dev & Clin Evaluat, Sendai, Miyagi 9808574, Japan
[2] Tohoku Univ, Grad Sch Pharmaceut Sci & Med, Dept Clin Pharmacol & Therapeut, Sendai, Miyagi 980, Japan
[3] Tohoku Univ, Century COE Program 21, Comprehens Res & Educ Ctr Planning Drug Dev & Cli, Sendai, Miyagi, Japan
[4] Tohoku Univ, Grad Sch Med, Dept Med Genet, Sendai, Miyagi 980, Japan
关键词
home blood pressure measurement; blood pressure control; cross-sectional study;
D O I
10.1038/sj.jhh.1002320
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
The usefulness of self-measurements of blood pressure (BP) at home (home BP measurements) in hypertensive patients has been reported by many studies. Several national guidelines recommend the use of home BP measurements to achieve better hypertension control. The objective of this study was to clarify the association between home BP measurements and hypertension treatment among 2363 essential hypertensive patients taking antihypertensive drugs. Compared to the 543 (23.0%) patients who had not taken home BP measurements, the 1820 (77.0%) patients who had taken home BP measurements were significantly older, included a higher proportion of males, included a higher proportion with a family history of hypertension, took a greater number of antihypertensive drugs and alpha blockers and took antihypertensive drugs more often in the evening. Home BP measurements were associated with significantly better control of home and office BP levels. Compared to patients who had not taken home BP measurements, the adjusted odds ratios for good control of morning home BPs, evening home BPs and office BPs in patients who had taken home BP measurements were 1.46 (95% confidential interval (CI) 1.33-1.57), 1.35 (95% CI 1.21-1.47) and 1.23 (95% CI 1.06-1.37), respectively. Home BP measurements were associated with good hypertensive management. Our findings suggest that it is important that physicians recommend home BP measurements to their patients.
引用
收藏
页码:197 / 204
页数:8
相关论文
共 30 条
[1]   2003 World Health Organization (WHO)/International Society of Hypertension (ISH) statement on management of hypertension [J].
Afridi, I ;
Canny, J ;
Yao, CH ;
Christensen, B ;
Cooper, RS ;
Kadiri, S ;
Hill, S ;
Kaplan, N ;
Kuschnir, E ;
Lexchin, J ;
Mendis, S ;
Poulter, N ;
Psaty, BM ;
Rahn, KH ;
Sheps, SG ;
Whitworth, J ;
Yach, D ;
Bengoa, R ;
Ramsay, L ;
Kaplan, N ;
Mendis, S ;
Poulter, N ;
Whitworth, J .
JOURNAL OF HYPERTENSION, 2003, 21 (11) :1983-1992
[2]  
[Anonymous], 2006, HYPERTENS RES, V29, pS1
[3]   Use of 2003 European Society of Hypertension-European Society of Cardiology guidelines for predicting stroke using self-measured blood pressure at home: the Ohasama study [J].
Asayama, K ;
Ohkubo, T ;
Kikuya, M ;
Metoki, H ;
Obara, T ;
Hoshi, H ;
Hashimoto, J ;
Totsune, K ;
Satoh, H ;
Imai, Y .
EUROPEAN HEART JOURNAL, 2005, 26 (19) :2026-2031
[4]   Relationship between home blood pressure measurement and medication compliance and name recognition of antihypertensive drugs [J].
Ashida, T ;
Sugiyama, T ;
Okuno, S ;
Ebihara, A ;
Fujii, J .
HYPERTENSION RESEARCH, 2000, 23 (01) :21-24
[5]   Cardiovascular prognosis of "masked hypertension" detected by blood pressure self-measurement in elderly treated hypertensive patients [J].
Bobrie, G ;
Chatellier, G ;
Genes, N ;
Clerson, P ;
Vaur, L ;
Vaisse, L ;
Menard, J ;
Mallion, JM .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2004, 291 (11) :1342-1349
[6]   Seventh Report of the Joint National Committee on Prevention, Detection, Evaluation, and Treatment of High Blood Pressure [J].
Chobanian, AV ;
Bakris, GL ;
Black, HR ;
Cushman, WC ;
Green, LA ;
Izzo, JL ;
Jones, DW ;
Materson, BJ ;
Oparil, S ;
Wright, JT ;
Roccella, EJ .
HYPERTENSION, 2003, 42 (06) :1206-1252
[7]   Prevalence of home blood pressure measurement among selected hypertensive patients: Results of a multicenter survey from six hospital outpatient hypertension clinics in Italy [J].
Cuspidi, C ;
Meani, S ;
Lonati, L ;
Fusi, V ;
Magnaghi, G ;
Garavelli, G ;
Palumbo, G ;
Pini, C ;
Vaccarella, A ;
Parati, G ;
Leonetti, G ;
Zanchetti, A .
BLOOD PRESSURE, 2005, 14 (04) :251-256
[8]   Home blood pressure measurement and its relationship with blood pressure control in a large selected hypertensive population [J].
Cuspidi, C ;
Meani, S ;
Fusi, V ;
Salerno, M ;
Valerio, C ;
Severgnini, B ;
Catini, E ;
Leonetti, G ;
Magrini, F ;
Zanchetti, A .
JOURNAL OF HUMAN HYPERTENSION, 2004, 18 (10) :725-731
[9]  
EDMONDS D, 1985, J HYPERTENS, V3, P31
[10]   The economic impact of the introduction of home blood pressure measurement for the diagnosis and treatment of hypertension [J].
Funahashi, Jin ;
Ohkubo, Takayoshi ;
Fukunaga, Hidefumi ;
Kikuya, Masahiro ;
Takada, Noriko ;
Asayama, Kei ;
Metoki, Hirohito ;
Obara, Taku ;
Inoue, Ryusuke ;
Hashimoto, Junichiro ;
Totsune, Kazuhito ;
Kobayashi, Makoto ;
Imai, Yutaka .
BLOOD PRESSURE MONITORING, 2006, 11 (05) :257-267