Diagnostic Accuracy of Three-Dimensional Endoanal Ultrasound for Anal Fistula: A Systematic Review and Meta-analysis

被引:6
|
作者
Li, Jin [1 ]
Chen, Shao-Na [1 ]
Lin, Yun-Yong [1 ]
Zhu, Zhi-Min [1 ]
Ye, Da-Lin [1 ]
Chen, Fei [1 ]
Qiu, Shao-Dong [1 ]
机构
[1] Guangzhou Med Univ, Affiliated Hosp 2, Dept Ultrasound, Guangzhou, Peoples R China
来源
TURKISH JOURNAL OF GASTROENTEROLOGY | 2021年 / 32卷 / 11期
关键词
Ultrasound; endoanal; three-dimensional; anal fistula; meta-analysis; PREOPERATIVE ASSESSMENT; PERIANAL FISTULAS; ENDOSONOGRAPHY; ULTRASONOGRAPHY; ANO;
D O I
10.5152/tjg.2021.20750
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background: Anal fistula is a relatively common anorectal disease. An accurate assessment of the main anal fistula type and the anatomy of the internal opening before surgery is necessary to obtain the best surgical results. Whether three-dimensional endoanal ultrasound (3D-EAUS) should be used as the first-line diagnostic tool for anal fistula is still controversial. The purpose of this study is to conduct a meta-analysis of the published literature on 3D-EAUS and anal fistula, and compare the results of 3D-EAUS and surgery to evaluate the diagnostic value of 3D-EAUS for anal fistula. Methods: An online search of databases in English included PubMed, Embase, and Cochrane Library. After the diagnostic accuracy of 3D-EAUS of all anal fistula types was integrated, a single-group rate meta-analysis was performed; we analyzed 3D-EAUS separately for the diagnosis of different anal fistula types, and conducted a meta-analysis of test accuracy. The analysis combined sensitivity, specificity, and the respective 95% CI, to draw a summary receiver operating characteristic curve (SROC), and estimate the area under curve (AUC). Results: Based on the inclusion criteria, we selected 8 studies covering 1057 cases of anal fistula and 548 cases of internal opening. The meta-analysis data show that 3D-EAUS has a total accuracy rate of 91% (95% CI, 88-94%). It has high sensitivity and specificity for different anal fistula classifications. The SROC curves for anal fistula internal openings were plotted, and the AUC was calculated to be 0.86 (95% CI, 0.83-0.89). Conclusions: 3D-EAUS can be used as the first-line diagnostic tool for anal fistula, because it has a high diagnostic accuracy for most anal fistulas. However, due to the insufficient diagnostic accuracy of 3D-EAUS for complex fistulas, 3D-EAUS combined with MRI examination can be used to more accurately detect the secondary extension of complex fistulas, so as to describe the complete anatomy of the fistula in more detail.
引用
收藏
页码:913 / 922
页数:10
相关论文
共 50 条
  • [1] A Diagnostic Accuracy Meta-analysis of Endoanal Ultrasound and MRI for Perianal Fistula Assessment
    Siddiqui, Muhammed R. S.
    Ashrafian, Hutan
    Tozer, Phil
    Daulatzai, Najib
    Burling, David
    Hart, Ailsa
    Athanasiou, Thanos
    Phillips, Robin K.
    DISEASES OF THE COLON & RECTUM, 2012, 55 (05) : 576 - 585
  • [2] A DIAGNOSTIC ACCURACY META-ANALYSIS OF ENDOANAL ULTRASOUND AND MRI FOR PERIANAL FISTULA ASSESSMENT
    Siddiqui, M. R. S.
    Ashrafian, H.
    Tozer, P.
    Daulatzai, N.
    Burling, D.
    Hart, A.
    Athanasiou, T.
    Phillips, R. K.
    GUT, 2012, 61 : A233 - A234
  • [3] Postoperative three-dimensional endoanal ultrasound findings and relation to anal fistula plug failure
    Falt, Ursula Aho
    Zawadzki, Antoni
    Starck, Marianne
    Bohe, Mans
    Regner, Sara
    Johnson, Louis B.
    SCANDINAVIAN JOURNAL OF GASTROENTEROLOGY, 2023, 58 (10) : 1200 - 1206
  • [4] Diagnostic accuracy of three-dimensional contrast-enhanced ultrasound for focal liver lesions A protocol for systematic review and meta-analysis
    Qu, Meijng
    Jia, Zhaohua
    Sun, Lipeng
    Wang, Hui
    MEDICINE, 2021, 100 (51)
  • [5] Impact of three-dimensional endoanal ultrasound on the outcome of anal fistula surgery: a prospective cohort study
    Ding, J. -H.
    Bi, L. -X.
    Zhao, K.
    Feng, Y. -Y.
    Zhu, J.
    Zhang, B.
    Yin, S. -H.
    Zhao, Y. -J.
    COLORECTAL DISEASE, 2015, 17 (12) : 1104 - 1112
  • [6] Three-dimensional endoanal ultrasound assessment of the anal sphincters: Reproducibility
    Olsen, Ingrid P.
    Augensen, Kare
    Wilsgaard, Tom
    Kiserud, Torvid
    ACTA OBSTETRICIA ET GYNECOLOGICA SCANDINAVICA, 2008, 87 (06) : 675 - 681
  • [7] A diagnostic accuracy meta-analysis of endoanal ultrasound (EAUS) and magnetic resonance imaging (MRI) for perianal fistula assessment
    Siddiqui, M.
    Ashrafian, H.
    Athanasiou, T.
    Hart, A.
    Phillips, R.
    BRITISH JOURNAL OF SURGERY, 2012, 99 : 145 - 145
  • [8] Comparison of clinical outcomes of anal fistula plug and endoanal advancement flap repair treating the complex anal fistula: a systematic review and meta-analysis
    An, Yongkang
    Chen, Xueqing
    Tian, Maosheng
    Qi, Wenyue
    Gao, Jihua
    UPDATES IN SURGERY, 2023, 75 (08) : 2103 - 2115
  • [9] Comparison of clinical outcomes of anal fistula plug and endoanal advancement flap repair treating the complex anal fistula: a systematic review and meta-analysis
    Yongkang An
    Xueqing Chen
    Maosheng Tian
    Wenyue Qi
    Jihua Gao
    Updates in Surgery, 2023, 75 : 2103 - 2115
  • [10] Detecting postpartum anal sphincter injuries with three-dimensional endoanal ultrasound: a prospective diagnostic study
    Larsson, Charlotta
    Huber, Malin
    Vestberg, Margareta
    Tunon, Katarina
    Strigard, Karin
    Nordin, Par
    Lindam, Anna