Background: Up to 2007 there was no formal external quality assurance programme for plasma free metanephrines. A pilot programme was conceived by the AACB (Australian Association of Clinical Biochemists) Working Party on biogenic amines. With support from the AACB and Royal College of Pathologists of Australasia Quality Assurance programmes, a pilot study was developed. Data from this study are presented for the first time. Methods: Twelve lyophilized plasma samples were distributed to 15 centres. Samples were spiked with metanephrine (metadrenaline), normetanephrine (normetadrenaline) and 3-methoxytyramine, all derived from human urine. Concentrations were arranged in a linear relationship. The analytes were present at six levels and samples were duplicated. Results: High-pressure liquid chromatography and tandem mass spectrometry methods showed acceptable precision but in general enzyme immunoassay displayed a higher degree of imprecision as well as a negative bias. Conclusions: Differences in calibration and matrix effects are likely to have been responsible for the discrepancy between chromatographic and immunoassay methods. These differences need to be further examined although efforts at standardization between different methods have been hampered by the lack of a universal calibrator for plasma metanephrines. Meanwhile, a laboratory's performance characteristics can be monitored and enhanced by participation in suitable external quality assurance programmes.
引用
收藏
页码:137 / 142
页数:6
相关论文
共 13 条
[1]   Plasma free Metanephrine measurement using automated online solid-phase extraction HPLC-Tandem mass Spectrometry [J].
de Jong, Wilhelmina H. A. ;
Graham, Kendon S. ;
van der Molen, Jan C. ;
Links, Thera P. ;
Morris, Michael R. ;
Ross, H. Alec ;
de Vries, Elisabeth G. E. ;
Kema, Ido P. .
CLINICAL CHEMISTRY, 2007, 53 (09) :1684-1693
[2]   Biochemical and clinical manifestations of dopamine-producing paragangliomas: Utility of plasma methoxytyramine [J].
Eisenhofer, G ;
Goldstein, DS ;
Sullivan, P ;
Csako, G ;
Brouwers, FM ;
Lai, EW ;
Adams, KT ;
Pacak, K .
JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM, 2005, 90 (04) :2068-2075
[3]   Plasma free metanephrines are superior to urine and plasma catecholamines and urine catecholamine metabolites for the investigation of phaeochromocytoma [J].
Hickman, Peter E. ;
Leong, Michelle ;
Chang, Julia ;
Wilson, Susan R. ;
McWhinney, Brett .
PATHOLOGY, 2009, 41 (02) :173-177
[4]   Measurement of plasma free metanephrine and normetanephrine by liquid chromatographym-tandem mass spectrometry for diagnosis of pheochromocytoma [J].
Lagerstedt, SA ;
O'Kane, DJ ;
Singh, RJ .
CLINICAL CHEMISTRY, 2004, 50 (03) :603-611
[5]  
LENDERS JWM, 1993, CLIN CHEM, V39, P97
[6]   Biochemical diagnosis of pheochromocytoma - Which test is best? [J].
Lenders, JWM ;
Pacak, K ;
Walther, MM ;
Linehan, WM ;
Mannelli, M ;
Friberg, P ;
Keiser, HR ;
Goldstein, DS ;
Eisenhofer, G .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2002, 287 (11) :1427-1434
[7]   Multicenter study on the diagnostic value of a new RIA for the detection of free plasma metanephrines in the work-up for pheochromocytoma [J].
Lenz, Tomas ;
Zorner, Joachim ;
Kirchmaier, Carl ;
Pillitteri, Daniele ;
Badenhoop, Klaus ;
Bartel, Christine ;
Geiger, Helmut ;
Hasselbacher, Katrin ;
Tuschy, Ulrich ;
Westermann, Juergen ;
Salewski, Lothar .
PHEOCHROMOCYTOMA, 2006, 1073 :358-373
[8]   Pheochromocytoma: recommendations for clinical practice from the First International Symposium [J].
Pacak, Karel ;
Eisenhofer, Graeme ;
Ahlman, Hakan ;
Bornstein, Stefan R. ;
Gimenez-Roqueplo, Anne-Paule ;
Grossman, Ashley B. ;
Kimura, Noriko ;
Mannelli, Massimo ;
McNicol, Anne Marie ;
Tischler, Arthur S. .
NATURE CLINICAL PRACTICE ENDOCRINOLOGY & METABOLISM, 2007, 3 (02) :92-102
[9]   Biochemical detection of phaeochromocytoma: why are we continuing to ignore the evidence? [J].
Peaston, Robert T. ;
Ball, Stephen .
ANNALS OF CLINICAL BIOCHEMISTRY, 2008, 45 :6-10
[10]   Proficiency test of plasma free and total metanephrines: report from a study group [J].
Pillai, Dilo ;
Ross, H. Alec ;
Kratzsch, Juergen ;
Pedrosa, William ;
Kema, Ido ;
Hoad, Kirsten ;
Rouaix, Nathalie ;
Fathi, Marc ;
Nader, Herbert ;
Mathian, Bruno ;
Grouzmann, Eric .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2009, 47 (06) :786-790