Effect of sodium-ion implantation on the corrosion resistance and bioactivity of titanium

被引:14
|
作者
Krupa, D
Baszkiewicz, J
Rajchel, B
Barcz, A
Sobczak, JW
Bilinski, A
机构
[1] Warsaw Univ Technol, PL-02507 Warsaw, Poland
[2] Inst Nucl Phys, PL-31342 Krakow, Poland
[3] Inst Electr Mat Technol, PL-02668 Warsaw, Poland
[4] Polish Acad Sci, Inst Phys Chem, PL-01224 Warsaw, Poland
关键词
titanium; implantation; sodium; bioactivity; corrosion;
D O I
10.1016/j.vacuum.2005.01.020
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The corrosion resistance and bioactivity of titanium after sodium-ion implantation were examined. Polished samples were implanted with a dose of 10(17) Na+/cm(2) at a beam energy of 25 keV. The chemical composition of the surface layer formed during the implantation was determined by X-ray photoelectron spectroscopy (XPS) and secondary ion mass spectrometry (SIMS). The bioactivity of the samples was evaluated by soaking them in a simulated body fluid (SBF) at 37 degrees C for 168 and 720 h. The corrosion resistance in SBF at 37 degrees C was determined by electrochemical methods after exposure in SBF for various times. The results obtained indicate that sodium-ion implantation improve the corrosion resistance after short-term exposures. During an exposure in SBF, calcium phosphates precipitate on the sample surface but they do not form a continuous layer. (c) 2005 Elsevier Ltd. All rights reserved.
引用
收藏
页码:161 / 166
页数:6
相关论文
共 50 条
  • [1] The effect of sodium-ion implantation on the properties of titanium
    Baszkiewicz, J.
    Krupa, D.
    Kozubowski, J. A.
    Rajchel, B.
    Lewandowska-Szumiel, M.
    Barcz, A.
    Sobczak, J. W.
    Kosinski, A.
    Chroscicka, A.
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2008, 19 (09) : 3081 - 3091
  • [2] The effect of sodium-ion implantation on the properties of titanium
    J. Baszkiewicz
    D. Krupa
    J. A. Kozubowski
    B. Rajchel
    M. Lewandowska-Szumieł
    A. Barcz
    J. W. Sobczak
    A. Kosiński
    A. Chróścicka
    Journal of Materials Science: Materials in Medicine, 2008, 19 : 3081 - 3091
  • [3] Effect of calcium-ion implantation on the corrosion resistance and biocompatibility of titanium
    Krupa, D
    Baszkiewicz, J
    Kozubowski, JA
    Barcz, A
    Sobczak, JW
    Bilinski, A
    Lewandowska-Szumiel, M
    Rajchel, B
    BIOMATERIALS, 2001, 22 (15) : 2139 - 2151
  • [4] Effect of Nitrogen Ion Implantation on Microstructure and Improvement of Titanium Corrosion Resistance
    Ali Shokouhy
    Mahmood Ghoraneviss
    Majid Borghei
    Mehdi Yari
    Majid M. Larijani
    S. H. Haji Hosseini
    Afshin Asadpour
    Journal of Fusion Energy, 2011, 30 : 190 - 194
  • [5] Effect of phosphorus-ion implantation on the corrosion resistance and biocompatibility of titanium
    Krupa, D
    Baszkiewicz, J
    Kozubowski, JA
    Barcz, A
    Sobczak, JW
    Bilinski, A
    Lewandowska-Szumiel, M
    Rajchel, B
    BIOMATERIALS, 2002, 23 (16) : 3329 - 3340
  • [6] Effect of Nitrogen Ion Implantation on Microstructure and Improvement of Titanium Corrosion Resistance
    Shokouhy, Ali
    Ghoraneviss, Mahmood
    Borghei, Majid
    Yari, Mehdi
    Larijani, Majid M.
    Hosseini, S. H. Haji
    Asadpour, Afshin
    JOURNAL OF FUSION ENERGY, 2011, 30 (02) : 190 - 194
  • [7] Effect of calcium and phosphorus ion implantation on the corrosion resistance and biocompatibility of titanium
    Krupa, D
    Baszkiewicz, J
    Kozubowski, JA
    Lewandowska-Szumiel, M
    Barcz, A
    Sobczak, JW
    Bilinski, A
    Rajchel, A
    BIO-MEDICAL MATERIALS AND ENGINEERING, 2004, 14 (04) : 525 - 536
  • [8] SODIUM-ION IMPLANTATION INTO SILICON
    KOROL, VM
    PHYSICA STATUS SOLIDI A-APPLIED RESEARCH, 1988, 110 (01): : 9 - 34
  • [9] Corrosion resistance and bioactivity of titanium after surface treatment by three different methods: ion implantation, alkaline treatment and anodic oxidation
    D. Krupa
    J. Baszkiewicz
    J. A. Kozubowski
    J. Mizera
    A. Barcz
    J. W. Sobczak
    A. Biliński
    B. Rajchel
    Analytical and Bioanalytical Chemistry, 2005, 381 : 617 - 625
  • [10] Corrosion resistance and bioactivity of titanium after surface treatment by three different methods: ion implantation, alkaline treatment and anodic oxidation
    Krupa, D
    Baszkiewicz, J
    Kozubowski, JA
    Mizera, J
    Barcz, A
    Sobczak, JW
    Bilinski, A
    Rajchel, B
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2005, 381 (03) : 617 - 625