The five percent electrode system for high-resolution EEG and ERP measurements

被引:1399
作者
Oostenveld, R
Praamstra, P
机构
[1] Univ Nijmegen Hosp, Inst Neurol, Dept Clin Neurophysiol, NL-6500 HB Nijmegen, Netherlands
[2] Univ Nijmegen, Dept Med & Biophys, Nijmegen, Netherlands
[3] Univ Birmingham, Behav Brain Sci Ctr, Birmingham, W Midlands, England
关键词
electrode placement; high resolution EEG; high resolution ERP; nomenclature;
D O I
10.1016/S1388-2457(00)00527-7
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objective: A system for electrode placement is described. It is designed for studies on topography and source analysis of spontaneous and evoked EEG activity. Method: The proposed system is based on the extended International 10-20 system which contains 74 electrodes, and extends this system up to 345 electrode locations. Results: The positioning and nomenclature of the electrode system is described, and a subset of locations is proposed as especially useful for modern EEG/ERP systems, often having 128 channels available. Conclusion: Similar to the extension of the 10-20 system to the 10-10 system ('10% system'), proposed in 1985, the goal of this new extension to a 10-5 system is to further promote standardization in high-resolution EEG studies. (C) 2001 Elsevier Science Ireland Ltd. All rights reserved.
引用
收藏
页码:713 / 719
页数:7
相关论文
共 16 条
  • [1] [Anonymous], 1994, J Clin Neurophysiol, V11, P111
  • [2] Chatrian G. E., 1985, American Journal of EEG Technology, V25, P83
  • [3] MODIFIED NOMENCLATURE FOR THE 10-PERCENT ELECTRODE SYSTEM
    CHATRIAN, GE
    LETTICH, E
    NELSON, PL
    [J]. JOURNAL OF CLINICAL NEUROPHYSIOLOGY, 1988, 5 (02) : 183 - 186
  • [4] TOPOGRAPHY OF THE N400 - BRAIN ELECTRICAL-ACTIVITY REFLECTING SEMANTIC EXPECTANCY
    CURRAN, T
    TUCKER, DM
    KUTAS, M
    POSNER, MI
    [J]. ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1993, 88 (03): : 188 - 209
  • [5] Imaging unconscious semantic priming
    Dehaene, S
    Naccache, L
    Le Clec'H, G
    Koechlin, E
    Mueller, M
    Dehaene-Lambertz, G
    van de Moortele, PF
    Le Bihan, D
    [J]. NATURE, 1998, 395 (6702) : 597 - 600
  • [6] Klem G H, 1999, Electroencephalogr Clin Neurophysiol Suppl, V52, P3
  • [7] A rapid method for determining standard 10/10 electrode positions for high resolution EEG studies
    Le, J
    Lu, M
    Pellouchoud, E
    Gevins, A
    [J]. ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1998, 106 (06): : 554 - 558
  • [8] IFCN standards for digital recording of clinical EEG
    Nuwer, MR
    Comi, G
    Emerson, R
    Fuglsang-Frederiksen, A
    Guérit, JM
    Hinrichs, H
    Ikeda, A
    Luccas, FJC
    Rappelsburger, P
    [J]. ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1998, 106 (03): : 259 - 261
  • [9] RECORDING ELECTRODE SITE NOMENCLATURE
    NUWER, MR
    [J]. JOURNAL OF CLINICAL NEUROPHYSIOLOGY, 1987, 4 (02) : 121 - 133
  • [10] The functional neuroanatomy of novelty processing: Integrating ERP and fMRI results
    Opitz, B
    Mecklinger, A
    Friederici, AD
    von Cramon, DY
    [J]. CEREBRAL CORTEX, 1999, 9 (04) : 379 - 391