Preconcentration of Cu(II), Cd(II) and Pb(II) on Amberlite XAD-4 Resin Functionalized with N,N′-Bis(o-vanillinidene)ethylenediamine and Their Determination by FAAS in Water Samples

被引:13
作者
Efendioglu, Aysegul [1 ]
Asci, Mehtap Yagan [1 ]
Bati, Bekir [1 ]
机构
[1] Ondokuz Mayis Univ, Fac Art & Sci, Dept Chem, TR-55139 Samsun, Turkey
关键词
ATOMIC-ABSORPTION-SPECTROMETRY; SOLID-PHASE EXTRACTION; CHELATING RESIN; TRACE-ELEMENTS; ONLINE PRECONCENTRATION; ENVIRONMENTAL-SAMPLES; SORPTION BEHAVIOR; METAL-IONS; SEPARATION; COPRECIPITATION;
D O I
10.2116/analsci.26.1283
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new polystyrene divinylbenzene-based chelating resin was synthesized by functionalizing Amberlite XAD-4 with N,N'-bis(o-vanillinidene)ethylenediamine. This resin was capable of preconcentrating Cu(II), Cd(II) and Pb(II) in water samples prior to FAAS determination. Various parameters, such as the pH, eluent type and concentration, volume of the eluent and the sample, and diverse ion effects have been studied. The recoveries for the analytes under the optimum working conditions were higher than 95%. The accuracy of the method was tested with standard reference materials (MBH-C31XB20, GBW-02703 and CRM BCR-32) and Cd(II), Cu(II) and Pb(II) standard solutions. The method was successfully applied to water samples.
引用
收藏
页码:1283 / 1288
页数:6
相关论文
共 44 条
[1]  
Asci MY, 2008, TURK J CHEM, V32, P431
[2]   The use of Agrobacterium tumefacients immobilized on Amberlite XAD-4 as a new biosorbent for the column preconcentration of iron(III), cobalt(II), manganese(II) and chromium(III) [J].
Baytak, S ;
Türker, AR .
TALANTA, 2005, 65 (04) :938-945
[3]   Use of an o-aminobenzoic acid-functionalized XAD-4 copolymer resin for the separation and preconcentration of heavy metal(II) ions [J].
Çekiç, SD ;
Filik, H ;
Apak, R .
ANALYTICA CHIMICA ACTA, 2004, 505 (01) :15-24
[4]  
Dalman Ö, 2007, TURK J CHEM, V31, P631
[5]   Sorption behaviour of lanthanum(III), neodymium(III), terbium(III), thorium(IV) and uranium(VI) on Amberlite XAD-4 resin functionalized with bicine ligands [J].
Dev, K ;
Pathak, R ;
Rao, GN .
TALANTA, 1999, 48 (03) :579-584
[6]   Determination of some trace metals in water and sediment samples by flame atomic absorption spectrometry after coprecipitation with cerium (IV) hydroxide [J].
Divrikli, Ü ;
Elçi, L .
ANALYTICA CHIMICA ACTA, 2002, 452 (02) :231-235
[7]   Solid-phase extraction of Fe(III), Pb(II) and Cr(III) in environmental samples on amberlite XAD-7 and their determinations by flame [J].
Divrikli, Umit ;
Akdogan, Abdullah ;
Soylak, Mustafa ;
Elci, Latif .
JOURNAL OF HAZARDOUS MATERIALS, 2007, 149 (02) :331-337
[8]   Bi(III)4-methylpiperidinedithiocarbamate coprecipitation procedure for separation-pre-concentration of trace metal ions in water samples by flame atomic absorption spectrometric determination [J].
Efendioglu, Ayseguel ;
Yagan, Mehtap ;
Bati, Bekir .
JOURNAL OF HAZARDOUS MATERIALS, 2007, 149 (01) :160-165
[9]   Solid phase extraction method for the determination of iron, lead and chromium by atomic absorption spectrometry using Amberite XAD-2000 column in various water samples [J].
Elci, Latif ;
Kartal, Aslihan A. ;
Soylak, Mustafa .
JOURNAL OF HAZARDOUS MATERIALS, 2008, 153 (1-2) :454-461
[10]   Preconcentration and speciation of chromium in drinking water samples by coupling of on-line sorption on activated carbon to ETAAS determination [J].
Gil, RA ;
Cerutti, S ;
Gásquez, JA ;
Olsina, RA ;
Martinez, LD .
TALANTA, 2006, 68 (04) :1065-1070