Solving liquid chromatography mass spectrometry coelution problems in the analysis of environmental samples by multivariate curve resolution

被引:68
|
作者
Peré-Trepat, E
Lacorte, S
Tauler, R
机构
[1] CSIC, Inst Chem & Environm Res, Dept Environm Chem, ES-08034 Barcelona, Spain
[2] Univ Barcelona, Dept Analyt Chem, Barcelona 08028, Spain
关键词
multivariate curve resolution; alternating least squares; MCR-ALS; LC-MS; coelution; short column; fast chromatography; biocides; environmental samples;
D O I
10.1016/j.chroma.2005.04.089
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Multivariate curve resolution-alternating least squares (MCR-ALS) is shown to be a powerful tool to resolve coelution problems in liquid chromatograpy-mass spectrometry (LC-MS) in scan mode. This investigation was performed using two types of LC columns, one traditional LC column of 25 cm length with a slow gradient and a shorter LC column of 7.5 cm with a rapid gradient which allowed much faster analysis and save of reagents and solvents. Mixtures of multiple biocide compounds were simultaneously analyzed in standard mixtures and in environmental samples (sediment and wastewater samples) with little sample pretreatment. Using the more traditional LC 25 cm column, all biocide compounds were properly resolved by MCR-ALS and quantitatively analyzed with estimated errors always below 20%. When fast chromatography (LC column of 7.5 cm) was used, MCR-ALS resolution of the more strongly coeluted compounds was also achieved but limitations were found in their simultaneous quantitative determination, specially for environmental samples. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:111 / 122
页数:12
相关论文
共 50 条
  • [31] DETERMINATION OF QUINOXALINES AND THEIR TWO MAIN METABOLITES IN ENVIRONMENTAL WATER SAMPLES BY LIQUID CHROMATOGRAPHY-TANDEM MASS SPECTROMETRY
    Yang, Haicui
    He, Limin
    Liu, Yahong
    Bian, Kui
    Hu, Fengyang
    Fang, Binghu
    ANALYTICAL LETTERS, 2014, 47 (08) : 1421 - 1433
  • [32] Multivariate curve-resolution analysis of pesticides in water samples from liquid chromatographic-diode array data
    Maggio, Ruben M.
    Damiani, Patricia C.
    Olivieri, Alejandro C.
    TALANTA, 2011, 83 (04) : 1173 - 1180
  • [33] Possibilities of multivariate curve resolution and partial least squares in the resolution of coeluted peaks in liquid chromatography with electrochemical detection
    Gonzalez-Garcia, Olga
    Arino, Cristina
    Manuel Diaz-Cruz, Jose
    Esteban, Miquel
    CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2008, 93 (01) : 49 - 57
  • [34] Multivariate curve resolution modeling of liquid chromatography-mass spectrometry data in a comparative study of the different endogenous metabolites behavior in two tomato cultivars treated with carbofuran pesticide
    Siano, Gabriel G.
    Sanchez Perez, Isidro
    Gil Garcia, Maria D.
    Martinez Galera, Maria
    Goicoeche, Hector C.
    TALANTA, 2011, 85 (01) : 264 - 275
  • [35] A liquid chromatography/tandem mass spectrometry assay for the analysis of atomoxetine in human plasma and in vitro cellular samples
    Appel, David I.
    Brinda, Bryan
    Markowitz, John S.
    Newcorn, Jeffrey H.
    Zhu, Hao-Jie
    BIOMEDICAL CHROMATOGRAPHY, 2012, 26 (11) : 1364 - 1370
  • [36] Impurity analysis of gentamicin bulk samples by improved liquid chromatography-ion trap mass spectrometry
    Chao Zheng
    BoChu Wang
    MingJuan Wang
    Jos Hoogmartens
    Ann Van Schepdael
    Erwin Adams
    Science China Chemistry, 2011, 54 : 1518 - 1528
  • [37] DEVELOPMENT AND APPLICATION OF A TEST MIXTURE FOR UNTARGETED LIQUID CHROMATOGRAPHY-MASS SPECTROMETRY ANALYSIS OF URINE SAMPLES
    Torres, Clarisse L.
    Sardela, Vinicius F.
    Scalco, Fernanda B.
    Neto, Francisco R. de Aquino
    Garrett, Rafael
    QUIMICA NOVA, 2022, 45 (01): : 89 - 96
  • [38] Impurity analysis of gentamicin bulk samples by improved liquid chromatography-ion trap mass spectrometry
    Zheng Chao
    Wang BoChu
    Wang MingJuan
    Hoogmartens Jos
    Schepdael Ann Van
    Adams Erwin
    SCIENCE CHINA-CHEMISTRY, 2011, 54 (09) : 1518 - 1528
  • [39] Impurity analysis of gentamicin bulk samples by improved liquid chromatography-ion trap mass spectrometry
    HOOGMARTENS Jos
    SCHEPDAEL Ann Van
    ADAMS Erwin
    Science China(Chemistry), 2011, (09) : 1518 - 1528
  • [40] Quantitative Mass Spectrometry Imaging Using Multivariate Curve Resolution and Deep Learning: A Case Study
    Golpelichi, Fatemeh
    Parastar, Hadi
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2023, 34 (02) : 236 - 244