Evaluation of a Stretch Sensor for its Inedited Application in Tracking Hand Finger Movements

被引:0
作者
Sbcrnini, Laura [1 ]
Pallotti, Antonio [1 ]
Saggio, Giovanni [1 ]
机构
[1] Univ Roma Tor Vergata, Dept Elect Engn, Via Politecn 1, I-00133 Rome, Italy
来源
2016 IEEE INTERNATIONAL SYMPOSIUM ON MEDICAL MEASUREMENTS AND APPLICATIONS (MEMEA) | 2016年
关键词
flex sensor; stretch sensor; sensor characterization; hand finger tracking; INSTRUMENTED GLOVE; FLEXION; SYSTEMS;
D O I
暂无
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Flex sensors are frequently used as wearable tools for unobtrusively tracking human joint movements. Among all the flex sensor types, the resistive ones are the mostly adopted thanks to their electrical and mechanical properties capable to furnish electrical resistance values related to the amount of mechanical flexion. In particular, resistive flex sensors have been finding many applications when embedded into gloves, in order to evaluate fine flexion/extension movements of the finger joints. Within this frame, here we investigate the possible utilization of a different type of flex sensors embedded into gloves, i.e., the stretch ones, since the stretch sensors change in resistance proportionally to their stretch that can be just obtained when laid on-top of a finger joint. In such a view, here we compare the characteristics of commercial flex and stretch sensors obtained by means of an ad-hoc setup and protocol. Results demonstrate the different peculiarities of the two different types of sensors, so to determine when it is convenient to adopt one type instead of the other.
引用
收藏
页码:626 / 631
页数:6
相关论文
共 19 条
[1]   The Use of Fiber Bragg Grating Sensors in Biomechanics and Rehabilitation Applications: The State-of-the-Art and Ongoing Research Topics [J].
Al-Fakih, Ebrahim ;
Abu Osman, Noor Azuan ;
Adikan, Faisal Rafiq Mahamd .
SENSORS, 2012, 12 (10) :12890-12926
[2]   Advances in wearable technology and applications in physical medicine and rehabilitation [J].
Bonato P. .
Journal of NeuroEngineering and Rehabilitation, 2 (1)
[3]  
Borghetti M., 2014, P IEEE INT S MED MEA, P1
[4]   Sensorized Glove for Measuring Hand Finger Flexion for Rehabilitation Purposes [J].
Borghetti, Michela ;
Sardini, Emilio ;
Serpelloni, Mauro .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2013, 62 (12) :3308-3314
[5]  
Coelho R.R., 2013, P BIOS BIOR C BRC 20, P1
[6]   A new approach to accurate measurement of uniaxial joint angles based on a combination of accelerometers and gyroscopes [J].
Dejnabadi, H ;
Jolles, BM ;
Aminian, K .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2005, 52 (08) :1478-1484
[7]  
Dipietro L, 2003, J REHABIL RES DEV, V40, P179
[8]   A survey of glove-based systems and their applications [J].
Dipietro, Laura ;
Sabatini, Angelo M. ;
Dario, Paolo .
IEEE TRANSACTIONS ON SYSTEMS MAN AND CYBERNETICS PART C-APPLICATIONS AND REVIEWS, 2008, 38 (04) :461-482
[9]   Wearable conductive fiber sensors for multi-axis human joint angle measurements [J].
Gibbs P.T. ;
Asada H.H. .
Journal of NeuroEngineering and Rehabilitation, 2 (1)
[10]   Ergonomic Evaluation of Biomechanical Hand Function [J].
Lee, Kyung-Sun ;
Jung, Myung-Chul .
SAFETY AND HEALTH AT WORK, 2015, 6 (01) :9-17