Comparison of the GlideScope® videolaryngoscope and the Macintosh laryngoscope for double-lumen tube intubation

被引:60
作者
Hsu, H. -T. [1 ,2 ]
Chou, S. -H. [3 ,4 ]
Wu, P. -J. [1 ]
Tseng, K. -Y. [1 ]
Kuo, Y. -W. [1 ]
Chou, C. -Y. [1 ]
Cheng, K. -I. [1 ,5 ]
机构
[1] Kaohsiung Med Univ Hosp, Dept Anesthesia, Kaohsiung, Taiwan
[2] Kaohsiung Med Univ, Inst Med, Coll Med, Kaohsiung, Taiwan
[3] Kaohsiung Med Univ Hosp, Dept Chest Surg, Kaohsiung, Taiwan
[4] Kaohsiung Med Univ, Coll Med, Sch Med, Kaohsiung, Taiwan
[5] Kaohsiung Med Univ, Fac Anesthesiol, Coll Med, Kaohsiung, Taiwan
关键词
TRACHEAL INTUBATION; VIDEO LARYNGOSCOPE; ENDOBRONCHIAL TUBE; DIFFICULT AIRWAY;
D O I
10.1111/j.1365-2044.2011.07049.x
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Intubation with a double-lumen tube is important for achieving one-lung ventilation and facilitating thoracic surgery. The GlideScope (R) videolaryngoscope (Verathon Inc., Bothell, WA, USA) is designed to assist tracheal intubation for patients with a difficult airway. We wished to compare the GlideScope and direct laryngoscopy for double-lumen tube intubation. Sixty adult patients requiring a double-lumen tube for thoracic surgery and predicted uncomplicated laryngoscopy were randomly assigned to a direct Macintosh laryngoscopy group (n = 30) or a GlideScope group (n = 30). The mean (SD) duration of intubation was longer in the Macintosh group (62.5 (29.7) s) than in the GlideScope group (45.6 (10.7) s; p = 0.007). There was no difference in the success of the first attempt at intubation (26/30 (87%) and 30/30 (100%) for Macintosh and GlideScope groups, respectively; p = 0.112). The incidence of sore throat and hoarseness was higher in the Macintosh group (18 (60%) and 14 (47%), respectively) than in the GlideScope group (6 (20%) and 4 (13%), respectively; p = 0.003 and 0.004). We conclude that double-lumen tube intubation in patients with predicted normal laryngoscopy is easier using the GlideScope videolaryngoscope than the Macintosh laryngoscope.
引用
收藏
页码:411 / 415
页数:5
相关论文
共 16 条
[1]   Routine Clinical Practice Effectiveness of the Glidescope in Difficult Airway Management An Analysis of 2,004 Glidescope Intubations, Complications, and Failures from Two Institutions [J].
Aziz, Michael F. ;
Healy, David ;
Kheterpal, Sachin ;
Fu, Rongwei F. ;
Dillman, Dawn ;
Brambrink, Ansgar M. .
ANESTHESIOLOGY, 2011, 114 (01) :34-41
[2]   Sequential rotation to insert a left double-lumen endotracheal tube using the GlideScopeA® [J].
Bustamante, Sergio ;
Parra-Sanchez, Ivan ;
Apostolakis, John .
CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 2010, 57 (03) :282-283
[3]   GlideScope-assisted double-lumen endobronchial tube placement in a patient with an unanticipated difficult airway [J].
Chen, Albert ;
Lai, Hsien-Yong ;
Lin, Pei-Chin ;
Chen, Tsung-Ying ;
Shyr, Ming-Hwang .
JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2008, 22 (01) :170-172
[4]   A comparative study on the usefulness of the Glidescope or Macintosh laryngoscope when intubating normal airways [J].
Choi, Guen Seok ;
Lee, Eun-Ha ;
Lim, Chae Seong ;
Yoon, Seok-Hwa .
KOREAN JOURNAL OF ANESTHESIOLOGY, 2011, 60 (05) :339-343
[5]   Comparison of GlideScope video laryngoscope and intubating laryngeal mask airway with direct laryngoscopy for endotracheal intubation [J].
Cinar, Orhan ;
Cevik, Erdem ;
Yildirim, Ali Osman ;
Yasar, Mehmet ;
Kilic, Erden ;
Comert, Bilgin .
EUROPEAN JOURNAL OF EMERGENCY MEDICINE, 2011, 18 (02) :117-120
[6]  
Cooper RM, 2005, CAN J ANAESTH, V52, P191, DOI 10.1007/BF03027728
[7]  
Edward Morgan G., 2006, Clinical Anesthesiology, ed
[8]   Using a Glidescope for intubation witb a double lumen endotracheal tube [J].
Hernandez, AA ;
Wong, DH .
CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 2005, 52 (06) :658-659
[9]   The Association Between Obesity and Difficult Prehospital Tracheal Intubation [J].
Holmberg, Timothy J. ;
Bowman, Stephen M. ;
Warner, Keir J. ;
Vavilala, Monica S. ;
Bulger, Eileen M. ;
Copass, Michael K. ;
Sharar, Sam R. .
ANESTHESIA AND ANALGESIA, 2011, 112 (05) :1132-1138
[10]   A comparison between the GlideScope® Video Laryngoscope and direct laryngoscope in paediatric patients with difficult airways - a pilot study [J].
Karsli, C. ;
Armstrong, J. ;
John, J. .
ANAESTHESIA, 2010, 65 (04) :353-357