Comparison of a tube-holder (Rescuefix) versus tape-tying for minimizing double-lumen tube displacement during lateral positioning in thoracic surgery A prospective, randomized controlled study

被引:5
作者
Byun, Sung Hye [1 ]
Kang, Su Hwang [1 ]
Kim, Jong Hae [1 ]
Ryu, Taeha [1 ]
Kim, Baek Jin [1 ]
Jung, Jin Yong [1 ]
机构
[1] Catholic Univ Daegu, Sch Med, Dept Anesthesiol & Pain Med, 33 Duryugongwon Ro 17 Gil, Daegu, South Korea
关键词
one-lung ventilation; DLT displacement; double-lumen endotracheal tube; endotracheal tube holder; lateral position; ENDOTRACHEAL-TUBE; ANESTHESIA; PLACEMENT; FIXATION; DIAMETER; PATIENT; DEPTH; SIZE;
D O I
10.1097/MD.0000000000004486
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Double-lumen endotracheal tubes (DLTs) are often displaced during change from the supine to the lateral decubitus position. The aim of this study was to determine whether Rescuefix, a recently developed tube-holder device, is more effective than the traditional tape-tying method for tube security during lateral positioning. Methods: Patients were randomly assigned to a Rescuefix (R) group (n=22) or a tape (T) group (n=22). After intubation with a left-sided DLT and adjustment of the appropriate DLT position using a fiberoptic bronchoscope, the DLT was fixed firmly at the side of the mouth by either Rescuefix or Durapore tape. "Tracheal depth" (from the tracheal carina to the elbow connector of the DLT) and "bronchial depth" (from the left bronchial carina to the elbow connector of the DLT) were measured in the supine position using the fiberoptic bronchoscope. After positional change, tracheal and bronchial depths were measured as described above. As the primary endpoint, displacement of the DLT during positional change was evaluated by obtaining the difference in depths measured when the patient was in the supine and lateral decubitus positions. In addition, after lateral positioning of the patient, any requirement for repositioning the DLT was recorded. Results: After lateral positioning, there were no significant differences in changes in tracheal and bronchial depths between the groups (tracheal depth 6.1 +/- 4.4mm [R group] and 9.1 +/- 5.6mm [T group], P=0.058; bronchial depth 6.5 +/- 4.4mm [R group], and 8.5 +/- 4.6mm [T group], P=0.132). Although the amount of change in tracheal and bronchial depths was not different between the groups, the need to reposition the DLT was significantly lower in the R group than in the T group (32% vs 68%, P=0.016). Conclusion: This study demonstrated that use of Rescuefix did not reduce the amount of DLT displacement, but it did significantly lower the incidence of DLT repositioning compared with the tape-tying method. Therefore, Rescuefix appears to be an effective alternative to minimizing DLT displacement during lateral positioning in thoracic surgery.
引用
收藏
页数:7
相关论文
共 16 条
  • [1] Tracheal diameter predicts double-lumen tube size: A method for selecting left double-lumen tubes
    Brodsky, JB
    Macario, A
    Mark, JBD
    [J]. ANESTHESIA AND ANALGESIA, 1996, 82 (04) : 861 - 864
  • [2] BRODSKY JB, 1991, ANESTH ANALG, V73, P570
  • [3] Update on tracheobronchial anatomy and flexible fiberoptic bronchoscopy in thoracic anesthesia
    Campos, Javier H.
    [J]. CURRENT OPINION IN ANESTHESIOLOGY, 2009, 22 (01) : 4 - 10
  • [4] Major complications of airway management in the UK: results of the Fourth National Audit Project of the Royal College of Anaesthetists and the Difficult Airway Society. Part 1: Anaesthesia
    Cook, T. M.
    Woodall, N.
    Frerk, C.
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 2011, 106 (05) : 617 - 631
  • [5] The effects of endobronchial cuff inflation on double-lumen endobronchial tube movement after lateral decubitus positioning
    Desiderio, DP
    Burt, M
    Kolker, AC
    Fischer, ME
    Reinsel, R
    Wilson, RS
    [J]. JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 1997, 11 (05) : 595 - 598
  • [6] Evaluation of an approach to choosing a left double-lumen tube size based on chest computed tomographic scan measurement of left mainstem bronchial diameter
    Hannallah, M
    Benumof, JL
    Silverman, PM
    Kelly, LC
    Lea, D
    [J]. JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 1997, 11 (02) : 168 - 171
  • [7] Double lumen tube location predicts tube malposition and hypoxaemia during one lung ventilation
    Inoue, S
    Nishimine, N
    Kitaguchi, K
    Furuya, H
    Taniguchi, S
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 2004, 92 (02) : 195 - 201
  • [8] SHIFTS IN ENDOTRACHEAL TUBE POSITION DUE TO CHEST COMPRESSIONS: A SIMULATION COMPARISON BY FIXATION METHOD
    Komasawa, Nobuyasu
    Fujiwara, Shunsuke
    Miyazaki, Shinichiro
    Ohchi, Fumihiro
    Minami, Toshiaki
    [J]. JOURNAL OF EMERGENCY MEDICINE, 2015, 48 (02) : 241 - 246
  • [9] Predicting Optimal Insertion Depth of a Left-sided Double-Lumen Endobronchial Tube
    Lin, Wei-Lin
    Cherng, Chen-Hwan
    [J]. JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2016, 30 (04) : 942 - 946
  • [10] Lydia C, 2014, MILLERS ANESTHESIA, P1240