A general tumour control probability model for non-uniform dose distributions

被引:10
作者
Gonzalez, Sara J. [1 ]
Carando, Daniel G. [2 ]
机构
[1] Comis Nacl Energia Atom, UEN, Ciudad Buenos Aires, Argentina
[2] Univ Buenos Aires, Fac Exactas Nat, Dept Matemat, RA-1428 Buenos Aires, DF, Argentina
来源
MATHEMATICAL MEDICINE AND BIOLOGY-A JOURNAL OF THE IMA | 2008年 / 25卷 / 02期
关键词
tumor control probability; non-uniform dose distribution; equivalent uniform dose;
D O I
10.1093/imammb/dqn012
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Perfectly uniform dose distributions over target volumes are almost impossible to achieve in clinical practice, due to surrounding normal tissues dose constraints that are commonly imposed to treatment plans. This article introduces a new approach to compute tumour control probabilities (TCPs) under inhomogeneous dose conditions. The equivalent subvolume model presented here does not assume independence between cell responses and can be derived from any homogeneous dose TCP model. To check the consistency of this model, some natural properties are shown to hold, including the so-called uniform dose theorem. In the spirit of the equivalent uniform dose (EUD) concept introduced by Niemierko (1997, Med. Phys., 24, 103-110), the probability-EUD is defined. This concept together with the methodology introduced to compute TCPs for inhomogeneous doses is applied to different uniform dose TCP models. As expected, the TCP takes into account the whole dose distribution over the target volume, but it is influenced more strongly by the low-dose regions. Finally, the proposed methodology and other approaches to the inhomogeneous dose scenario are compared.
引用
收藏
页码:171 / 184
页数:14
相关论文
共 9 条
  • [1] Boron neutron capture therapy of cancer: Current status and future prospects
    Barth, RF
    Coderre, JA
    Vicente, MGH
    Blue, TE
    [J]. CLINICAL CANCER RESEARCH, 2005, 11 (11) : 3987 - 4002
  • [2] Tumor volume and local control probability: Clinical data and radiobiological interpretations
    Bentzen, SM
    Thames, HD
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1996, 36 (01): : 247 - 251
  • [3] DOSIMETRIC PRECISION REQUIREMENTS IN RADIATION-THERAPY
    BRAHME, A
    [J]. ACTA RADIOLOGICA ONCOLOGY, 1984, 23 (05): : 379 - 391
  • [4] First BNCT treatment of a skin melanoma in Argentina:: dosimetric analysis and clinical outcome
    González, SJ
    Bonomi, MR
    Cruz, GAS
    Blaumann, HR
    Larrieu, OAC
    Menéndez, P
    Rebagliati, RJ
    Longhino, J
    Feld, DB
    Dagrosa, MA
    Argerich, C
    Castiglia, SG
    Batistoni, DA
    Liberman, SJ
    Roth, BMC
    [J]. APPLIED RADIATION AND ISOTOPES, 2004, 61 (05) : 1101 - 1105
  • [5] DOSE HOMOGENEITY IN BORON NEUTRON-CAPTURE THERAPY USING AN EPITHERMAL NEUTRON BEAM
    KONIJNENBERG, MW
    DEWIT, LGH
    MIJNHEER, BJ
    RAAIJMAKERS, CPJ
    WATKINS, PRD
    [J]. RADIATION RESEARCH, 1995, 142 (03) : 327 - 339
  • [6] Reporting and analyzing dose distributions: A concept of equivalent uniform dose
    Niemierko, A
    [J]. MEDICAL PHYSICS, 1997, 24 (01) : 103 - 110
  • [7] THE ROLE OF RADIOTHERAPY IN RECURRENT AND METASTATIC MALIGNANT-MELANOMA - A CLINICAL RADIOBIOLOGICAL STUDY
    OVERGAARD, J
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1986, 12 (06): : 867 - 872
  • [8] A PROOF THAT UNIFORM DOSE GIVES THE GREATEST TCP FOR FIXED INTEGRAL DOSE IN THE PLANNING TARGET VOLUME
    WEBB, S
    EVANS, PM
    SWINDELL, W
    DEASY, JO
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1994, 39 (11) : 2091 - 2098
  • [9] A MODEL FOR CALCULATING TUMOR-CONTROL PROBABILITY IN RADIOTHERAPY INCLUDING THE EFFECTS OF INHOMOGENEOUS DISTRIBUTIONS OF DOSE AND CLONOGENIC CELL-DENSITY
    WEBB, S
    NAHUM, AE
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1993, 38 (06) : 653 - 666