In vitro testing for hip head-neck taper tribocorrosion: A review of experimental methods

被引:3
|
作者
Wight, Christian M. [1 ]
Schemitsch, Emil H. [2 ]
机构
[1] Univ Toronto, Inst Biomat & Biomed Engn, Roseburgh Bldg,164 Coll St,Room 407, Toronto, ON M5S 3G9, Canada
[2] Univ Western Ontario, Schulich Sch Med & Dent, Dept Surg, Div Orthopaed Surg, London, ON, Canada
关键词
Hip prosthesis; corrosion; tribocorrosion; trunnionosis; in vitro testing; FRETTING CREVICE CORROSION; MODULAR JUNCTIONS; FEMORAL-HEAD; MORSE TAPER; METAL; WEAR; ARTHROPLASTY; TRUNNION; BEHAVIOR; CONTACT;
D O I
10.1177/09544119221074582
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In vitro test methods are challenged by the multi-factorial nature of head-neck taper connection tribocorrosion due to the consequences of simplification. Incorrect study design and misinterpretation of results has led to contradictory findings regarding important factors affecting head-neck taper tribocorrosion. This review seeks to highlight important considerations when developing in vitro test methods, to help researchers strengthen their study design and analyze the implications of others' design decisions. The advantages, disadvantages, limitations and procedural considerations for finite element analyses, electrochemical studies and in vitro simulations related to head-neck taper connection tribocorrosion are discussed. Finite element analysis offers an efficient method for studying large ranges of mechanical parameters. However, they are limited by neglecting electrochemical, biological and fluid flow factors. Electrochemical studies may be preferred if these factors are considered important. Care must be taken in interpreting data from electrochemical studies, particularly when different materials are compared. Differences in material valence and toxicity affect clinical translation of electrochemical studies' results. At their most complex, electrochemical studies attempt to simulate all aspects of headneck taper connection tribocorrosion in a bench top study. Effective execution requires in-depth knowledge of the tribocorrosion phenomenon, the involved mechanisms, and their measures such that each study design decision is fully informed.
引用
收藏
页码:469 / 482
页数:14
相关论文
共 50 条
  • [21] Hip Flexion After Birmingham Hip Resurfacing Role of Cup Anteversion, Anterior Femoral Head-Neck Offset, and Head-Neck Ratio
    Malviya, Ajay
    Lingard, Elizabeth A.
    Malik, Atul
    Bowman, Russell
    Holland, James P.
    JOURNAL OF ARTHROPLASTY, 2010, 25 (03): : 387 - 391
  • [22] An adaptive finite element simulation of fretting wear damage at the head neck taper junction of total hip replacement: The role of taper angle mismatch
    Fallahnezhad, Khosro
    Oskouei, Reza H.
    Badnava, Hojjat
    Taylor, Mark
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2017, 75 : 58 - 67
  • [23] Micromotion analysis of the head-neck interface of a PEEK artificial hip prosthesis
    Xu, Handong
    Zhang, Dekun
    Chen, Kai
    Zhang, Xinyue
    MATERIALS RESEARCH EXPRESS, 2019, 6 (11)
  • [24] Otto Aufranc Award: Large Heads Do Not Increase Damage at the Head-neck Taper of Metal-on-polyethylene Total Hip Arthroplasties
    Triantafyllopoulos, Georgios K.
    Elpers, Marcella E.
    Burket, Jayme C.
    Esposito, Christina I.
    Padgett, Douglas E.
    Wright, Timothy M.
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2016, 474 (02) : 330 - 338
  • [25] The Influence of Head Size on Corrosion and Fretting Behaviour at the Head-Neck Interface of Artificial Hip Joints
    Dyrkacz, Richard M. R.
    Brandt, Jan-M.
    Ojo, Olanrewaju A.
    Turgeon, Thomas R.
    Wyss, Urs P.
    JOURNAL OF ARTHROPLASTY, 2013, 28 (06): : 1036 - 1040
  • [26] Corrosion of the Head-neck Junction After Total Hip Arthroplasty
    Jennings, Jason M.
    Dennis, Douglas A.
    Yang, Charlie C.
    JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2016, 24 (06) : 349 - 356
  • [27] CORR InsightsA®: Does Surface Topography Play a Role in Taper Damage in Head-neck Modular Junctions?
    Fernandez-Fairen, Mariano
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2016, 474 (10) : 2243 - 2245
  • [28] Does Surface Topography Play a Role in Taper Damage in Head-neck Modular Junctions?
    Pourzal, Robin
    Hall, Deborah J.
    Ha, Nguyen Q.
    Urban, Robert M.
    Levine, Brett R.
    Jacobs, Joshua J.
    Lundberg, Hannah J.
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2016, 474 (10) : 2232 - 2242
  • [29] Risk Factors Associated With Early Complications of Revision Surgery for Head-Neck Taper Corrosion in Metal-on-Polyethylene Total Hip Arthroplasty
    Kwon, Young-Min
    Rossi, Daniel
    MacAuliffe, John
    Peng, Yun
    Arauz, Paul
    JOURNAL OF ARTHROPLASTY, 2018, 33 (10): : 3231 - 3237
  • [30] Design, Material, and Seating Load Effects on In Vitro Fretting Corrosion Performance of Modular Head-Neck Tapers
    Ouellette, Eric S.
    Mali, Sachin A.
    Kim, Jua
    Grostefon, Justin
    Gilbert, Jeremy L.
    JOURNAL OF ARTHROPLASTY, 2019, 34 (05): : 991 - 1002