共 23 条
Frequency analysis of the fibrillatory activity from surface ECG lead V1 and intracardiac recordings: implications for mapping of AF
被引:24
作者:
Hsu, Nei-Wei
[2
]
Lin, Yenn-Jiang
[1
,3
,4
]
Tai, Ching-Tai
[1
]
Kao, Tsair
[5
]
Chang, Shih-Lin
[1
,3
,4
]
Wongcharoen, Wanwarang
[1
]
Lo, Li-Wei
[1
,3
,4
]
Udyavar, Arneya R.
[1
]
Hu, Yu-Feng
[1
]
Tso, Han-Wen
[3
,4
]
Chen, Yi-Jen
[6
]
Higa, Satoshi
[7
]
Chen, Shih-Ann
[1
,3
,4
]
机构:
[1] Taipei Vet Gen Hosp, Div Cardiol, Dept Med, Taipei, Taiwan
[2] Taiwan I Lan Hosp, Dept Med, Ilan, Taiwan
[3] Natl Yang Ming Univ, Inst Clin Med, Taipei 112, Taiwan
[4] Natl Yang Ming Univ, Cardiovasc Res Inst, Taipei 112, Taiwan
[5] Natl Yang Ming Univ, Inst Biomed Engn, Taipei 112, Taiwan
[6] Taipei Med Univ, Wan Fan Hosp, Taipei, Taiwan
[7] Univ Ryukyus, Fac Med, Dept Internal Med 2, Okinawa, Japan
来源:
EUROPACE
|
2008年
/
10卷
/
04期
关键词:
atrial fibrillation;
atrial mapping;
electrogram;
frequency analysis;
D O I:
10.1093/europace/eun045
中图分类号:
R5 [内科学];
学科分类号:
1002 ;
100201 ;
摘要:
Aims Fibrillatory waves observed in the surface eLectrograms may be a direct reflection of the electro-physiologic mechanism of the atrial fibrillation (AF). This study compared the fibriltatory waves in the surface ECG and the individual intracardiac mapping sites in different types of paroxysmal AF Methods and results Thirty patients with paroxysmal AF originating from the pulmonary veins (PVs) or superior vena cava (SVC) were enrolled. Frequency analysis was performed on the intracardiac electro-grams recorded from various mapping sites in both atria sequentially with simultaneous surface electrogram recordings. The SVC-AF patients had a trend toward a higher DF in ECG lead V1 when compared with the PV-AF patients (7.35 +/- 2.09 vs. 5.89 +/- 0.79 Hz, P = 0.018). The mean dominant frequency (DF) of the LA mapping sites in the PV-AF patients was higher than that in the SVC-AF patients (7.06 +/- 0.66 vs. 6.13 +/- 0.96 Hz, P = 0.009), whereas the mean DF of the RA mapping sites was similar between the two groups (5.84 +/- 0.80 vs. 6.26 +/- 1.11 Hz, P = NS). The intra-class correlation coefficient (ICC) between the mean DF of the RA sites and V1 was higher (r = 0.21, P = 0.02) when compared with the mean DF of the LA sites (r = -0.007, P > 0.05). Furthermore, the maximal ICC was observed in the anterolateral RA free wall (r = 0.84, P < 0.001) and not the other anatomic sites of the RA and L.A. Conclusion The fibrillatory activity observed in ECG lead V1 correlated primarily with the activity of the anterolateral RA free wall and thus may be useful for detecting the AF source if it is close to that area.
引用
收藏
页码:438 / 443
页数:6
相关论文