Development of a new copper(II) ion-selective poly(vinyl chloride) membrane electrode based on 2-mercaptobenzoxazole

被引:0
作者
Akhond, M [1 ]
Ghaedi, M [1 ]
Tashkhourian, J [1 ]
机构
[1] Shiraz Univ, Dept Chem, Fac Sci, Shiraz 71454, Iran
关键词
copper(II) ion-selective electrode; ion sensor; PVC membrane; potentiometry; 2-mercaptobenzoxazole;
D O I
暂无
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Copper(II) ion-selective PVC membrane electrode based on 2-mercaptobenzoxazole as a new ionophore and o-nitrophenyl octyl ether (o-NPOE) as plasticizer is proposed. This electrode revealed good selectivity for Cu2+ over a wide variety of other metal ions. Effects of experimental parameters such as membrane composition, nature and amount of plasticizer, and concentration of internal solution on the potential response of Cu2+ sensor were investigated. The electrode exhibits good response for Cu2+ in a wide linear range of 5.0 x 10(-6)-1.6 x 10(-2) mol/L with a slope of 29.2 +/- 2.0 mV/decade. The response time of the sensor is less than 10 s, and the detection limit is 2.0 x 10(-6) mol/L. The electrode response was stable in pH range of 4-6. The lifetime of the electrode was about 2 months. The electrode revealed comparatively good selectivities with respect to many alkali, alkaline earth, and transition metal ions.
引用
收藏
页码:882 / 886
页数:5
相关论文
共 31 条
  • [1] AAMRANI FZE, 1999, ANAL CHIM ACTA, V402, P129
  • [2] Copper(II)-selective electrode based on dithioacetal
    Abbaspour, A
    Kamyabi, MA
    [J]. ANALYTICA CHIMICA ACTA, 2002, 455 (02) : 225 - 231
  • [3] Copper(II)-selective membrane electrode based on a recently synthesized naphthol-derivative Schiff's base
    Alizadeh, N
    Ershad, S
    Naeimi, H
    Sharghi, H
    Shamsipur, M
    [J]. FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1999, 365 (06): : 511 - 515
  • [4] AMMANN D, 1983, ION SEL ELECTRODE R, V5, P3
  • [5] [Anonymous], 1976, PURE APPL CHEM, V48, P127, DOI DOI 10.1351/PAC197648010127
  • [6] Antonisse MMG, 1999, ELECTROANAL, V11, P1035, DOI 10.1002/(SICI)1521-4109(199910)11:14<1035::AID-ELAN1035>3.0.CO
  • [7] 2-I
  • [8] RECENT ADVANCES IN THE DEVELOPMENT AND ANALYTICAL APPLICATIONS OF BIOSENSING PROBES
    ARNOLD, MA
    MEYERHOFF, ME
    [J]. CRC CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 1988, 20 (03): : 149 - 196
  • [9] Selectivity of liquid membrane ion-selective electrodes
    Bakker, E
    [J]. ELECTROANALYSIS, 1997, 9 (01) : 7 - 12
  • [10] Carrier-based ion-selective electrodes and bulk optodes. 1. General characteristics
    Bakker, E
    Buhlmann, P
    Pretsch, E
    [J]. CHEMICAL REVIEWS, 1997, 97 (08) : 3083 - 3132