Augmented reality-guided positioning system for radiotherapy patients

被引:15
作者
Li, Chunying [1 ,2 ,3 ]
Lu, Zhengda [1 ,2 ,3 ]
He, Mu [1 ,2 ,3 ]
Sui, Jianfeng [1 ,2 ,3 ]
Lin, Tao [1 ,2 ,3 ]
Xie, Kai [1 ,2 ,3 ]
Sun, Jiawei [1 ,2 ,3 ]
Ni, Xinye [1 ,2 ,3 ]
机构
[1] Nanjing Med Univ, Changzhou Peoples Hosp 2, Dept Radiotherapy, Changzhou 213003, Jiangsu, Peoples R China
[2] Nanjing Med Univ, Lab Med Phys Ctr, Nanjing, Peoples R China
[3] Changzhou Key Lab Med Phys, Changzhou, Jiangsu, Peoples R China
关键词
augmented reality; position setup; position setup error; radiation therapy; ALIGNMENT; ACCURACY; GUIDANCE; SKIN;
D O I
10.1002/acm2.13516
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In modern radiotherapy, error reduction in the patients' daily setup error is important for achieving accuracy. In our study, we proposed a new approach for the development of an assist system for the radiotherapy position setup by using augmented reality (AR). We aimed to improve the accuracy of the position setup of patients undergoing radiotherapy and to evaluate the error of the position setup of patients who were diagnosed with head and neck cancer, and that of patients diagnosed with chest and abdomen cancer. We acquired the patient's simulation CT data for the three-dimensional (3D) reconstruction of the external surface and organs. The AR tracking software detected the calibration module and loaded the 3D virtual model. The calibration module was aligned with the Linac isocenter by using room lasers. And then aligned the virtual cube with the calibration module to complete the calibration of the 3D virtual model and Linac isocenter. Then, the patient position setup was carried out, and point cloud registration was performed between the patient and the 3D virtual model, such the patient's posture was consistent with the 3D virtual model. Twenty patients diagnosed with head and neck cancer and 20 patients diagnosed with chest and abdomen cancer in the supine position setup were analyzed for the residual errors of the conventional laser and AR-guided position setup. Results show that for patients diagnosed with head and neck cancer, the difference between the two positioning methods was not statistically significant (P > 0.05). For patients diagnosed with chest and abdomen cancer, the residual errors of the two positioning methods in the superior and inferior direction and anterior and posterior direction were statistically significant (t = -5.80, -4.98, P < 0.05). The residual errors in the three rotation directions were statistically significant (t = -2.29 to -3.22, P < 0.05). The experimental results showed that the AR technology can effectively assist in the position setup of patients undergoing radiotherapy, significantly reduce the position setup errors in patients diagnosed with chest and abdomen cancer, and improve the accuracy of radiotherapy.
引用
收藏
页数:11
相关论文
共 29 条
[1]   Breast-shape changes during radiation therapy after breast-conserving surgery [J].
Alderliesten, Tanja ;
Heemsbergen, Wilma D. ;
Betgen, Anja ;
Topolnjak, Rajko ;
Elkhuizen, Paula H. M. ;
Van Vliet-Vroegindeweij, Corine ;
Remeijer, Peter .
PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2018, 6 :71-76
[2]   A review of setup error in supine breast radiotherapy using cone -beam computed tomography [J].
Batumalai, Vikneswary ;
Holloway, Lois ;
Delaney, Geoff P. .
MEDICAL DOSIMETRY, 2016, 41 (03) :225-229
[3]   Electromagnetic Transponder Based Tracking and Gating in the Radiotherapeutic Treatment of Thoracic Malignancies [J].
Boggs, Drexell H. ;
Popple, Richard ;
McDonald, Andrew ;
Minnich, Doug ;
Willey, Christopher D. ;
Spencer, Sharon ;
Shen, Sui ;
Dobelbower, Michael C. .
PRACTICAL RADIATION ONCOLOGY, 2019, 9 (06) :456-464
[4]   Quantifying false positional corrections due to facial motion using SGRT with open-face Masks [J].
Bry, Victoria ;
Licon, Anna Laura ;
McCulloch, James ;
Kirby, Neil ;
Myers, Pamela ;
Saenz, Daniel ;
Stathakis, Sotirios ;
Papanikolaou, Niko ;
Rasmussen, Karl .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2021, 22 (04) :172-183
[5]   Magnetic resonance-guided radiation therapy: A review [J].
Chin, Stephen ;
Eccles, Cynthia L. ;
McWilliam, Alan ;
Chuter, Robert ;
Walker, Emma ;
Whitehurst, Philip ;
Berresford, Joseph ;
Van Herk, Marcel ;
Hoskin, Peter J. ;
Choudhury, Ananya .
JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2020, 64 (01) :163-177
[6]   RAD-AR: RADiotherapy - Augmented Reality An augmented reality tool for radiotherapy implemented on consumer electronics devices [J].
Cosentino, Francesco ;
John, Nigel W. ;
Vaarkamp, Jaap .
2017 INTERNATIONAL CONFERENCE ON CYBERWORLDS (CW), 2017, :226-228
[7]   Quality improvement process to assess tattoo alignment, set-up accuracy and isocentre reproducibility in pelvic radiotherapy patients [J].
Elsner, Kelly ;
Francis, Kate ;
Hruby, George ;
Roderick, Stephanie .
JOURNAL OF MEDICAL RADIATION SCIENCES, 2014, 61 (04) :246-252
[8]   Bladder Cancer Radiotherapy Margins: A Comparison of Daily Alignment using Skin, Bone or Soft Tissue [J].
Foroudi, F. ;
Pham, D. ;
Bressel, M. ;
Wong, J. ;
Rolfo, A. ;
Roxby, P. ;
Kron, T. .
CLINICAL ONCOLOGY, 2012, 24 (10) :673-681
[9]  
French SB., 2014, THESIS
[10]   Use of surface-guided radiation therapy in combination with IGRT for setup and intrafraction motion monitoring during stereotactic body radiation therapy treatments of the lung and abdomen [J].
Heinzerling, John H. ;
Hampton, Carnell J. ;
Robinson, Myra ;
Bright, Megan ;
Moeller, Benjamin J. ;
Ruiz, Justin ;
Prabhu, Roshan ;
Burri, Stuart H. ;
Foster, Ryan D. .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2020, 21 (05) :48-55