Estimation of electrical backup for solar box cooker

被引:7
作者
Chaudhuri, TK [1 ]
机构
[1] Sardar Patel Renewable Energy Res Inst, Solar Energy Div, Vallabh Vidyanagar 388120, Gujarat, India
关键词
D O I
10.1016/S0960-1481(98)00774-5
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Incorporation of an electrical backup in a Solar Box Cooker (SBC) makes it operative throughout the year. The backup should be such that the essential characteristics of the solar cooker are retained and the energy consumption should be as low as possible. An estimate of electrical power requirement of a heater for an Indian SBC is presented considering its no-load figure of merit and energy balance at stagnation. It is found that a 160 W heater is sufficient for cooking. (C) 1999 Elsevier Science Ltd. All rights reserved.