Effects of stray lights on Faraday rotation measurement for polarimeter-interferometer system on EAST

被引:17
|
作者
Zou, Z. Y. [1 ,2 ]
Liu, H. Q. [1 ]
Ding, W. X. [3 ]
Chen, J. [3 ]
Brower, D. L. [3 ]
Lian, H. [1 ,2 ]
Wang, S. X. [1 ,2 ]
Li, W. M. [1 ,2 ]
Yao, Y. [1 ]
Zeng, L. [1 ]
Jie, Y. X. [1 ]
机构
[1] Chinese Acad Sci, Inst Plasma Phys, Hefei 230031, Anhui, Peoples R China
[2] Univ Sci & Technol China, Hefei 230026, Anhui, Peoples R China
[3] Univ Calif Los Angeles, Dept Phys & Astron, Los Angeles, CA 90095 USA
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2018年 / 89卷 / 01期
关键词
DESIGN;
D O I
10.1063/1.5012820
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A double-pass radially view 11 chords polarimeter-interferometer system has been operated on the experimental advanced superconducting tokamak and provides important current profile information for plasma control. Stray light originating from spurious reflections along the optical path (unwanted reflections from various optical components/mounts and transmissive optical elements such as windows, waveplates, and lens as well as the detectors) and also direct feedback from the retro-reflector used to realize the double-pass configuration can both contribute to contamination of the Faraday rotation measurement accuracy. Modulation of the Faraday rotation signal due to the interference from multiple reflections is observable when the interferometer phase (plasma density) varies with time. Direct reflection from the detector itself can be suppressed by employing an optical isolator consisting of a lambda/4-waveplate and polarizer positioned in front of the mixer. A Faraday angle oscillation during the density ramping up (or down) can be reduced from 5 degrees-10 degrees to 1 degrees-2 degrees by eliminating reflections from the detector. Residual modulation arising from misalignment and stray light from other sources must be minimized to achieve accurate measurements of Faraday rotation. Published by AIP Publishing.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] Faraday-effect polarimeter-interferometer system for current density measurement on EAST
    Liu, H. Q.
    Jie, Y. X.
    Ding, W. X.
    Brower, D. L.
    Zou, Z. Y.
    Li, W. M.
    Wang, Z. X.
    Qian, J. P.
    Yang, Y.
    Zeng, L.
    Lan, T.
    Wei, X. C.
    Li, G. S.
    Hu, L. Q.
    Wan, B. N.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2014, 85 (11):
  • [2] Optimization of the POlarimeter-INTerferometer diagnostics system on EAST
    Wang, Y. F.
    Liu, H. Q.
    Jie, Y. X.
    Lian, H.
    Chu, Y. Q.
    Li, W. M.
    Wang, S. X.
    Zhu, X.
    JOURNAL OF INSTRUMENTATION, 2020, 15 (06)
  • [3] EAST kinetic equilibrium reconstruction combining with Polarimeter-Interferometer internal measurement constraints
    Lian, H.
    Liu, H. Q.
    Li, K.
    Zou, Z. Y.
    Qian, J. P.
    Wu, M. Q.
    Li, G. Q.
    Zeng, L.
    Zang, Q.
    Lv, B.
    Jie, Y. X.
    JOURNAL OF INSTRUMENTATION, 2017, 12
  • [4] Design of line array detection scheme for Polarimeter-Interferometer system on EAST
    Yan, H. H.
    Liu, H. Q.
    Wang, S. X.
    Lian, H.
    Li, W. M.
    Jie, Y. X.
    JOURNAL OF INSTRUMENTATION, 2023, 18 (11)
  • [5] Study of retro reflector array for the polarimeter-interferometer system on EAST Tokamak
    Lan, T.
    Wang, S. X.
    Liu, H. Q.
    Liu, J.
    Jie, Y. X.
    Zou, Z. Y.
    Li, W. M.
    Gao, X.
    Qin, H.
    JOURNAL OF INSTRUMENTATION, 2015, 10
  • [6] A single-probe-beam double-heterodyne polarimeter-interferometer for plasma Faraday rotation measurements
    Howard, J.
    Muir, J.
    Glass, F.
    Hicks, N.
    JOURNAL OF INSTRUMENTATION, 2012, 7
  • [7] EAST equilibrium current profile reconstruction using polarimeter-interferometer internal measurement constraints
    Qian, J. P.
    Lao, L. L.
    Liu, H. Q.
    Ding, W. X.
    Zeng, L.
    Luo, Z. P.
    Ren, Q. L.
    Huang, Y.
    Huang, J.
    Brower, D. L.
    Hanada, K.
    Chen, D. L.
    Sun, Y. W.
    Shen, B.
    Gong, X. Z.
    Xiao, B. J.
    Wan, B. N.
    NUCLEAR FUSION, 2017, 57 (03)
  • [8] Opto-Mechanical systems design for polarimeter-interferometer on EAST
    Zou, Z. Y.
    Liu, H. Q.
    Ding, W. X.
    Brower, D. L.
    Li, W. M.
    Lan, T.
    Zeng, L.
    Yao, Y.
    Yang, Y.
    Jie, Y. X.
    FUSION ENGINEERING AND DESIGN, 2016, 112 : 251 - 256
  • [9] Improvement on Faraday rotation measurement affected by the stray lights on the HL-2A tokamak
    Wang, Z. H.
    Li, Y. G.
    Li, Y.
    Wang, H. X.
    Yi, J.
    Wen, R. N.
    Shi, Z. B.
    PHYSICA SCRIPTA, 2022, 97 (09)
  • [10] Internal magnetic field measurements by laser-based POlarimeter-INTerferometer (POINT) system on EAST
    Liu, H. Q.
    Jie, Y. X.
    Ding, W. X.
    Brower, D. L.
    Zou, Z. Y.
    Qian, J. P.
    Li, W. M.
    Yang, Y.
    Zeng, L.
    Zhang, S. B.
    Lan, T.
    Wang, S. X.
    Hanada, K.
    Wei, X. C.
    Hu, L. Q.
    Wan, B. N.
    JOURNAL OF INSTRUMENTATION, 2016, 11