Multiscale Contact Mechanics of Ankle Joint Implant: Comparison of Two Implant Models

被引:0
|
作者
Hodaei, Mohammad [1 ]
Farhang, Kambiz [1 ]
机构
[1] Southern Illinois Univ Carbondale, Dept Mech Engn & Energy Proc, Carbondale, IL 62901 USA
来源
2014 INTERNATIONAL CONFERENCE ON COMPUTATIONAL SCIENCE AND COMPUTATIONAL INTELLIGENCE (CSCI), VOL 2 | 2014年
关键词
Contact Mechanics; Implant; Enegy Loss; Roughness; Toxicity; REPLACEMENT; ARTHROPLASTY; ARTHRITIS;
D O I
10.1109/CSCI.2014.86
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
this paper compares two different types of ankle implants. The first is the cylinder-cylinder configuration in conformal contact and the second involves a cylinder-flat in contact. The interaction of implant rough surfaces including both elastic and plastic deformations is included in the contact model. The tibia and the talus surfaces are treated as macroscopically conforming cylinders in the first model and flat-cylinder in the second model, containing micron-scale roughness. The derived equations relate contact force on the implant and the minimum mean surface separation of the rough surfaces. Based on the distribution of asperity heights, the force is expressed using statistical integral function of asperity heights over possible region of interaction of the roughness of the tibia and the talus implant surfaces. Closed-form approximate equation relating contact force and minimum separation is used to obtain hysteretic energy loss per cycle in a load-unload sequence applied to the implant.
引用
收藏
页码:3 / 10
页数:8
相关论文
共 50 条
  • [21] Arthroscopic Resection of Distal Pole of the Scaphoid for Scaphotrapeziotrapezoid Joint Arthritis: Comparison between Simple Resection and Implant Interposition
    Pegoli, L.
    Pozzi, Alessandro
    Pivato, G.
    Luchetti, R.
    JOURNAL OF WRIST SURGERY, 2016, 5 (03) : 227 - 232
  • [22] Validation of a personalized ligament-constraining discrete element framework for computing ankle joint contact mechanics
    Peiffer, M.
    Duquesne, K.
    Van Oevelen, A.
    Burssens, A.
    De Mits, S.
    Maas, S. A.
    Atkins, P. R.
    Anderson, A. E.
    Audenaert, E. A.
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2023, 231
  • [23] Thumb Interphalangeal Joint Arthroplasty With a Surface Replacing Implant: Two-Year Results
    Schindele, S.
    Marks, M.
    Herren, D. B.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2022, 47 (12): : 1224.e1 - 1224.e7
  • [24] Malalignment of the total ankle replacement increases peak contact stresses on the bone-implant interface: a finite element analysis
    van Hoogstraten, Sanne W. G.
    Hermus, Joris
    Loenen, Arjan C. Y.
    Arts, Jacobus J.
    van Rietbergen, Bert
    BMC MUSCULOSKELETAL DISORDERS, 2022, 23 (01)
  • [25] Constraints in posterior-stabilised TKA kinematics: a comparison of two generations of an implant
    Pandit, Hemant
    van Duren, Bernard Hendrik
    Price, M.
    Tilley, S.
    Gill, Harinderjit Singh
    Thomas, Neil P.
    Murray, David W.
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2013, 21 (12) : 2800 - 2809
  • [26] Reflection of an ultrasonic wave on the bone-implant interface: Comparison of two-dimensional and three-dimensional numerical models
    Heriveaux, Yoann
    Haiat, Guillaume
    Vu-Hieu Nguyen
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2020, 147 (01) : EL32 - EL36
  • [27] A Simplified Model of Multiscale Electrical Contact Resistance and Comparison to Existing Closed Form Models
    Jackson, Robert L.
    Malucci, Robert D.
    Angadi, Santosh
    Polchow, J. Robert
    PROCEEDINGS OF THE FIFTY-FIFTH IEEE HOLM CONFERENCE ON ELECTRICAL CONTACTS, 2009, : 27 - +
  • [28] Effect of novel polyethylene insert configurations on bone-implant micromotion and contact stresses in total ankle replacement prostheses: a finite element analysis
    Xu, Zhi
    Gong, Xiaonan
    Hu, Zhengyuan
    Bian, Ruixiang
    Jin, Ying
    Li, Yuwan
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2024, 12
  • [29] Comparison of outcomes of three surgical approaches for proximal interphalangeal joint arthroplasty using a surface-replacing implant
    Bodmer, Elvira
    Marks, Miriam
    Hensler, Stefanie
    Schindele, Stephan
    Herren, Daniel B.
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2020, 45 (06) : 608 - 614
  • [30] Randomized prospective clinical trial of two implant systems for overdenture treatment: a comparison of the 2-year and 5-year results using the clinical implant performance scale
    Kwakman, JM
    Voorsmit, RACA
    Freihofer, HPM
    Van Waas, MAJ
    Geertman, ME
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1998, 27 (02) : 94 - 98