Beam shaper with optimized dose utility for helical cone-beam CT

被引:3
作者
Koehler, Thomas [1 ]
Brendel, Bernhard [1 ]
Proksa, Roland [1 ]
机构
[1] Philips Technol GmbH, Innovat Technol, Res Labs, D-22335 Hamburg, Germany
关键词
computed tomography; helical CT; dose reduction; beam-shaper; bowtie filter;
D O I
10.1118/1.3577766
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To develop a new design of an x-ray beam shaper for helical computed tomography ( CT) that increases the dose utilization. Methods: For typical reconstruction algorithms in helical CT, different data are utilized with different weights during back-projection. In particular, data of the outer detector rows, i.e., data acquired at larger cone-angles, are used with smaller weights than data from the central detector rows. Given this spatial variation of the back-projection weights, a beam shaper is designed that creates a spatial variation of the noise variance across the detector such that the used back-projection weights are the statistically optimal weights. The effect of the beam shaper on the reconstructed images are studied using simulated data and analytical as well as iterative reconstruction algorithms. Results: For a particular analytical reconstruction algorithm, we obtain an average reduction of the noise by 12% within the object. In combination with iterative reconstruction, the beam shaper creates an insensitivity to patient motion without introducing any heuristic data weighting. Conclusions: The demonstrated noise reduction by 12% is equivalent to a possible dose saving of 25%. This dose saving can be achieved by a relatively minor hardware change in the CT system and it does not require any changes to the reconstruction algorithm. (c) 2011 American Association of Physicists in Medicine. [DOI: 10.1118/1.3577766]
引用
收藏
页码:S76 / S84
页数:9
相关论文
共 20 条
[1]   Current concepts - Computed tomography - An increasing source of radiation exposure [J].
Brenner, David J. ;
Hall, Eric J. .
NEW ENGLAND JOURNAL OF MEDICINE, 2007, 357 (22) :2277-2284
[2]   Projected Cancer Risks From Computed Tomographic Scans Performed in the United States in 2007 [J].
de Gonzalez, Amy Berrington ;
Mahesh, Mahadevappa ;
Kim, Kwang-Pyo ;
Bhargavan, Mythreyi ;
Lewis, Rebecca ;
Mettler, Fred ;
Land, Charles .
ARCHIVES OF INTERNAL MEDICINE, 2009, 169 (22) :2071-2077
[3]  
Defrise M, 2010, P 1 INT C IM FORM XR, P82
[4]   Monotonic algorithms for transmission tomography [J].
Erdogan, H ;
Fessler, JA .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1999, 18 (09) :801-814
[5]  
Fessler JA., 2000, Handbook of Medical Imaging, V2, P1, DOI [DOI 10.1117/3.831079.CH1, DOI 10.1117/3.831079]
[6]   Redundant data and exact helical cone-beam reconstruction [J].
Heuscher, D ;
Brown, K ;
Noo, F .
PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (11) :2219-2238
[7]  
Hsieh J., 2003, COMPUT TOMOGR, V114
[8]   Extended parallel backprojection for standard three-dimensional and phase-correlated four-dimensional axial and spiral cone-beam CT with arbitrary pitch, arbitrary cone-angle, and 100% dose usage [J].
Kachelriess, M ;
Knaup, M ;
Kalender, WA .
MEDICAL PHYSICS, 2004, 31 (06) :1623-1641
[9]   Optimized Reconstruction Algorithm for Helical CT With Fractional Pitch Between 1PI and 3PI [J].
Katsevich, Alexander ;
Zamyatin, Alexander A. ;
Silver, Michael D. .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2009, 28 (07) :982-990
[10]  
Koehler T., 2009, Proceedings of the Fully 3D Meeting, P263