Retinal Optical Quality of Multifocal Refractive and Monofocal Intraocular Lenses

被引:3
作者
D'Oria, Francesco [1 ]
Nowrouzi, Ali [2 ]
del Barrio, Jorge Alio L. [3 ]
Versaci, Francesco [4 ]
Alio, Jorge L. [3 ]
机构
[1] Univ Bari, Dept Basic Med Sci Neurosci & Sense Organs, Sect Ophthalmol, I-70124 Bari, Italy
[2] Hosp Quironsalud, Ophthalmol Dept, Marbella 29670, Spain
[3] Miguel Hernandez Univ, Dept Ophthalmol, Alicante 03015, Spain
[4] Costruz Strumenti Oftalmici CSO, R&D Dept, I-50018 Florence, Italy
关键词
retinal image quality; multifocal refractive IOL; monofocal IOL; pyramidal aberrometer; PERFORMANCE; OUTCOMES; LIFE;
D O I
10.3390/photonics8120559
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
(1) Background: This study aimed to evaluate and compare the clinical optical image quality following implantation with different premium IOLs by the analysis of the point spread function (PSF) Strehl ratio using a Pyramidal WaveFront-based sensor (PWS) aberrometer at two different pupil sizes. (2) Methods: This study included 96 eyes of 70 patients implanted with: (1) 19 AcrySof SA60AT (control group); (2) 24 LENTIS Mplus LS-313 MF30; (3) 33 LENTIS Mplus LS-313 MF15; and (4) 20 Precizon Presbyopic. Main outcome measures were PSF Strehl ratio, PSF Strehl ratio excluding second-order aberrations (PSFw2), total root-mean-square (RMS), and low- and high-order aberrations' RMS measured by PWS aberrometer. Results: SA60AT had the highest significant PSFw2 Strehl ratio at both 3- and 4-mm pupil size (0.41 +/- 0.11 and 0.28 +/- 0.07) followed by LENTIS Mplus 15 (group C, 0.35 +/- 0.1 and 0.21 +/- 0.06) and a near tie between LENTIS MPLUS 30 (group B, 0.27 +/- 0.08 and 0.18 +/- 0.06) and Precizon Presbyopic (group D, 0.27 +/- 0.07 and 0.17 +/- 0.04). MPlus MF15 was found to be significantly better than MPlus MF30 at both 3.00 mm (p < 0.0001) and 4.00 mm (p = 0.002). (4) Conclusions: The PSFw2 represents a new tool to objectively evaluate the far distance retinal image quality of multifocal IOLs, and the far distance clinical image quality parameters measured by PWS aberrometer differed significantly according to the technology of the implanted lens.
引用
收藏
页数:7
相关论文
共 17 条
  • [1] Visual acuity comparison of 2 models of bifocal aspheric intraocular lenses
    Alfonso, Jose F.
    Puchades, Cristina
    Fernandez-Vega, Luis
    Montes-Mico, Robert
    Valcarcel, Beatriz
    Ferrer-Blasco, Teresa
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (04) : 672 - 676
  • [2] Retinal image quality with multifocal, EDoF, and accommodative intraocular lenses as studied by pyramidal aberrometry
    Alio, Jorge L.
    D'Oria, Francesco
    Toto, Francesca
    Balgos, Joan
    Palazon, Antonio
    Versaci, Francesco
    Alio del Barrio, Jorge L.
    [J]. EYE AND VISION, 2021, 8 (01)
  • [3] Light scattering in intraocular lenses explanted 15 to 40 years after surgery
    Alio, Jorge L.
    Arias, Augusto
    D'Oria, Francesco
    Toto, Francesca
    Del Barrio, Jorge Alio
    Duarte, Raul
    Artal, Pablo
    [J]. BIOMEDICAL OPTICS EXPRESS, 2021, 12 (06) : 3485 - 3494
  • [4] Alió JL, 2014, ESSENT OPHTHALMOL, P47, DOI 10.1007/978-3-319-09219-5_5
  • [5] Visual outcomes and optical performance of a monofocal intraocular lens and a new-generation multifocal intraocular lens
    Alio, Jorge L.
    Pinero, David P.
    Plaza-Puche, Ana B.
    Joanna Rodriguez, Maria
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (02) : 241 - 250
  • [6] Cedrone C, 1999, Ophthalmic Epidemiol, V6, P95, DOI 10.1076/opep.6.2.95.1562
  • [7] Adaptive optics for ophthalmic applications using a pyramid wavefront sensor
    Chamot, SR
    Dainty, C
    Esposito, S
    [J]. OPTICS EXPRESS, 2006, 14 (02): : 518 - 526
  • [8] Intraocular lens optics and aberrations
    Chang, Daniel H.
    Rocha, Karolinne M.
    [J]. CURRENT OPINION IN OPHTHALMOLOGY, 2016, 27 (04) : 298 - 303
  • [9] Comprehensive Evaluation of Retinal Image Quality in Comparing Different Aspheric to Spherical Intraocular Lens Implants
    Liao, Xuan
    Haung, Xiuqi
    Lan, Changjun
    Tan, Qingqing
    Wen, Baiwei
    Lin, Jia
    Tian, Jing
    [J]. CURRENT EYE RESEARCH, 2019, 44 (10) : 1098 - 1103
  • [10] Applications of wavefront technology
    Mello, Glauco Reggiani
    Rocha, Karolinne Maia
    Santhiago, Marcony R.
    Smadja, David
    Krueger, Ronald R.
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (09) : 1671 - 1683