共 41 条
3-E analysis and optimization of an organic rankine flash cycle integrated with a PEM fuel cell and geothermal energy
被引:99
作者:
Li, Zhixiong
[1
,2
]
Khanmohammadi, Shoaib
[3
]
Khanmohammadi, Saber
[4
,5
]
Al-Rashed, Abdullah A. A. A.
[6
]
Ahmadi, Pouria
[7
]
Afrand, Masoud
[8
,9
]
机构:
[1] Minjiang Univ, Engn Res Ctr, Fujian Univ Marine Intelligent Ship Equipment, Fuzhou 350108, Peoples R China
[2] Univ Wollongong, Sch Mech Mat Mechatron & Biomed Engn, Wollongong, NSW 2522, Australia
[3] Kermanshah Univ Technol, Dept Mech Engn, Kermanshah, Iran
[4] Univ Kashan, Fac Mech Engn, Kashan, Iran
[5] Univ Kashan, Energy Res Inst, Kashan, Iran
[6] Publ Author Appl Educ & Training, Coll Technol Studies, Dept Automot & Marine Engn Technol, Kuwait, Kuwait
[7] Univ Tehran, Coll Engn, Sch Mech Engn, AESL, POB 11155-4563, Tehran, Iran
[8] Ton Duc Thang Univ, Adv Inst Mat Sci, Lab Magnetism & Magnet Mat, Ho Chi Minh City, Vietnam
[9] Ton Duc Thang Univ, Fac Appl Sci, Ho Chi Minh City, Vietnam
关键词:
Geothermal energy;
PEM-FC;
Thermo-economic;
Multi-objective optimization;
HYDROGEN-PRODUCTION;
SYSTEM;
SOLAR;
POWER;
EXERGY;
DRIVEN;
MULTIGENERATION;
FLUID;
D O I:
10.1016/j.ijhydene.2019.09.233
中图分类号:
O64 [物理化学(理论化学)、化学物理学];
学科分类号:
070304 ;
081704 ;
摘要:
The current research deals with thermodynamic and economic analyses and optimization of a geothermal system integrated with organic Rankine flash cycle (ORFC) and a polymer electrolyte membrane fuel cell (PEM-FC). A thermodynamic model for ORFC and PEM-FC is developed to investigate employing the PEM-FC in a combined geothermal ORFC. A comparative study is carried out to determine the effect of applying PEM-FC in a geothermal based ORFC. The validation of PEM-FC simulation with experimental data from the literature shows a good agreement. The results of numerical modeling indicate that using the rejected heat in the PEM-FC instead of the low-temperature geothermal source can increase the net output power from 254.9 kW to 1628.9 kW and the exergy efficiency from 23.77% to 36.19%, in the case of R123 as working fluid for the ORC system. Furthermore, using the PEM-FC imposes 9.07 US$/h cost rate to the system. Additionally the parametric study shows that the net output power and the total cost rate of the system are two major objective functions for the optimization. Thus, a multi-objective genetic algorithm is applied to determine the optimal values of design parameters with respect to some practical constraints. The results of the multi-criteria optimization represent that the optimum value of decision variables with considered objective functions are T-1 = 116 degrees C, r(flash) = 0.55, P-FC = 230 kPa, and P-4 = 1208.4 kPa. (C) 2019 Hydrogen Energy Publications LLC. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:2168 / 2185
页数:18
相关论文