Augments and allografts in revision total knee arthroplasty - Usage and outcome using one modular revision prosthesis

被引:51
作者
Hockman, DE [1 ]
Ammeen, D [1 ]
Engh, GA [1 ]
机构
[1] Anderson Orthopaed Res Inst, Alexandria, VA 22306 USA
关键词
TKA; revision; bone deficiency; modularity; augments; allograft;
D O I
10.1016/j.arth.2004.09.059
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Sixty-five consecutive Coordinate (DePuy, Warsaw, Ind) revision total knee arthroplasties were eligible for minimum 5-year follow-up. Nine patients died and 2 patients were lost. Therefore, 54 knees (51 patients) had a known Outcome. Nine knees failed and required either revision or component removal. Eight additional knees were considered clinical failures. Despite the use of metallic augmentation in 89% of the knees, large structural allografts were required in 48% of the knees. Revisions with bone loss that required bulk allograft failed less often (19.2%) than revisions managed without bulk allografts (42.9%). Of 24 knees originally revised for osteolysis/polyethylene wear, only I required rerevision for the same mechanism of failure. Modular augments did not effectively address the bone loss and instability encountered in many instances at revision surgery. Survivorship of this implant was 79.4% +/- 13.7% at 8 years.
引用
收藏
页码:35 / 41
页数:7
相关论文
共 17 条
  • [1] THE EFFECT OF A STEM ON THE TIBIAL COMPONENT OF KNEE ARTHROPLASTY - A ROENTGEN STEREOPHOTOGRAMMETRIC STUDY OF UNCEMENTED TIBIAL COMPONENTS IN THE FREEMAN-SAMUELSON KNEE ARTHROPLASTY
    ALBREKTSSON, BEJ
    RYD, L
    CARLSSON, LV
    FREEMAN, MAR
    HERBERTS, P
    REGNER, L
    SELVIK, G
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1990, 72 (02): : 252 - 258
  • [2] The use of a modular rotating hinge component in salvage revision total knee arthroplasty
    Barrack, RL
    Lyons, TR
    Ingraham, RQ
    Johnson, JC
    [J]. JOURNAL OF ARTHROPLASTY, 2000, 15 (07) : 858 - 866
  • [3] BROOKS PJ, 1984, CLIN ORTHOP RELAT R, V184, P302
  • [4] Does implant selection affect outcome of revision knee arthroplasty?
    Bugbee, WD
    Ammeen, DJ
    Engh, GA
    [J]. JOURNAL OF ARTHROPLASTY, 2001, 16 (05) : 581 - 585
  • [5] Engh G A, 1999, Instr Course Lect, V48, P167
  • [6] Treatment of major defects of bone with bulk allografts and stemmed components during total knee arthroplasty
    Engh, GA
    Herzwurm, PJ
    Parks, NL
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1997, 79A (07) : 1030 - 1039
  • [7] GOFTON WT, 2002, CLIN ORTHOP RELAT R, V404, P158
  • [8] REVISION TOTAL KNEE ARTHROPLASTY WITH USE OF MODULAR COMPONENTS WITH STEMS INSERTED WITHOUT CEMENT
    HAAS, SB
    INSALL, JN
    MONTGOMERY, W
    WINDSOR, RE
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1995, 77A (11) : 1700 - 1707
  • [9] INSALL JN, 1982, CLIN ORTHOP RELAT R, V170, P123
  • [10] JONES RE, 2001, CLIN ORTHOP RELAT R, V392, P306