An Analytical Approach to Study the Blood Flow over a Nonlinear Tapering Stenosed Artery in Flow of Carreau Fluid Model

被引:34
作者
Ahmad, Riaz [1 ]
Farooqi, Asma [1 ]
Farooqi, Rashada [2 ]
Hamadneh, Nawaf N. [3 ]
Fayz-Al-Asad, Md [4 ]
Khan, Ilyas [5 ]
Sajid, Muhammad [6 ]
Bary, Ghulam [1 ]
Khan, Muhammad Farooq Saleem [7 ,8 ]
机构
[1] Yibin Univ, Fac Sci, Yibin 644000, Sichuan, Peoples R China
[2] POF Hosp, Wah Med Coll, Wah Cantt 47040, Pakistan
[3] Saudi Elect Univ, Coll Sci & Theoret Studies, Departrnent Basic Sci, Riyadh 11673, Saudi Arabia
[4] Bangladesh Univ Engn & Technol, Dept Math, Dhaka 1000, Bangladesh
[5] Majmaah Univ, Coll Sci Al Zulfi, Dept Math, Al Majmaah 11952, Majmaah, Saudi Arabia
[6] Yibin Univ, Fac Mat & Chem Engn, Yibin 644000, Sichuan, Peoples R China
[7] Yibin Univ, Fac Int Appl Technol, Yibin 644000, Sichuan, Peoples R China
[8] Tsinghua Univ, Sch Environm Sci & Technol, Beijing, Peoples R China
关键词
MICROPOLAR FLUID; NEWTONIAN FLUID; CREEPING MOTION; PULSATILE FLOW;
D O I
10.1155/2021/9921642
中图分类号
O1 [数学];
学科分类号
0701 ; 070101 ;
摘要
The current study provides an analytical approach to analyze the blood flow through a stenosed artery by using the Carreau fluid model. The flow governing equations are derived under the consideration of mild stenosis. Mathematical analysis has been carried out by considering the blood as non-Newtonian nature. Then, the analytical solution has been investigated by using the regular perturbation technique. The solutions obtained by this perturbation are up to the second-order in dimensionless Weissenberg number (We). The performed computations of various parameter values such as velocity, wall shear stress, shear stress, and resistance impedance at the stenotic throat are discussed in detail for different values of Weissenberg number (We). The obtained results demonstrate that for shear-thinning fluid, the fluid velocity increases with the increasing parameter m while opposite behavior is observed with the increase in We. Hence, the presented numerical analysis reveals many aspects of the flow by considering the blood as a non-Newtonian Carreau fluid model, and the presented model can be equally applicable to other bio-mathematical studies.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Mathematical modeling of blood flow through a stenosed artery under body acceleration
    Haghighi, Ahmad Reza
    Chalak, Soraya Asadi
    JOURNAL OF THE BRAZILIAN SOCIETY OF MECHANICAL SCIENCES AND ENGINEERING, 2017, 39 (07) : 2487 - 2494
  • [42] Two-layered micropolar fluid flow through stenosed artery: Effect of peripheral layer thickness
    Ikbal, Md A.
    Chakravarty, S.
    Mandal, P. K.
    COMPUTERS & MATHEMATICS WITH APPLICATIONS, 2009, 58 (07) : 1328 - 1339
  • [43] Effect of real and whole blood rheology on flow through an axisymmetric stenosed artery
    Chauhan, A.
    Sasmal, A. C.
    INTERNATIONAL JOURNAL OF ENGINEERING SCIENCE, 2021, 169
  • [44] Numerical investigation on the blood flow characteristics considering the axial rotation in stenosed artery
    Sung, Kun Hyuk
    Ro, Kyoung Chul
    Ryou, Hong Sun
    KOREA-AUSTRALIA RHEOLOGY JOURNAL, 2009, 21 (02) : 119 - 126
  • [45] JEFFREY FLUID MODEL FOR BLOOD FLOW THROUGH A TAPERED ARTERY WITH A STENOSIS
    Akbar, Noreen Sher
    Nadeem, S.
    Ali, Mohamed
    JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2011, 11 (03) : 529 - 545
  • [46] NUMERICAL STUDY OF THE NON-NEWTONIAN BLOOD FLOW IN A STENOSED ARTERY USING TWO RHEOLOGICAL MODELS
    Achab, Louiza
    Mahfoud, Mohamed
    Benhadid, Salah
    THERMAL SCIENCE, 2016, 20 (02): : 449 - 460
  • [47] Mathematical analysis of Carreau fluid flow and heat transfer within an eccentric catheterized artery
    Alsemiry, Reima D.
    Sayed, Hamed M.
    Amin, Norsarahaida
    ALEXANDRIA ENGINEERING JOURNAL, 2022, 61 (01) : 523 - 539
  • [48] Effect of body acceleration on pulsatile flow of Casson fluid through a mild stenosed artery
    Nagarani, P.
    Sarojamma, G.
    KOREA-AUSTRALIA RHEOLOGY JOURNAL, 2008, 20 (04) : 189 - 196
  • [49] Herschel-Bulkley Model of Blood Flow through a Stenosed Artery with the Effect of Chemical Reaction on Solute Dispersion
    Abidin, Siti Nurul Aifa Mohd Zainul
    Jaafar, Nurul Aini
    Ismail, Zuhaila
    MALAYSIAN JOURNAL OF FUNDAMENTAL AND APPLIED SCIENCES, 2021, 17 (04): : 457 - 474
  • [50] An implicit approach to the micropolar fluid model of blood flow under the effect of body acceleration
    Haghighi, Ahmad Reza
    Aliashrafi, Nooshin
    Asl, Mohammad Shahbazi
    MATHEMATICAL SCIENCES, 2020, 14 (03) : 269 - 277