Hemispherical Focal Macular Photopic Negative Response and Macular Inner Retinal Thickness in Open-Angle Glaucoma

被引:27
作者
Nakamura, Hajime [1 ]
Hangai, Masanori [1 ]
Mori, Satoshi [1 ]
Hirose, Fumitaka [1 ]
Yoshimura, Nagahisa [1 ]
机构
[1] Kyoto Univ, Grad Sch Med, Dept Ophthalmol & Visual Sci, Sakyo Ku, Kyoto 6068507, Japan
基金
日本学术振兴会;
关键词
OPTICAL COHERENCE TOMOGRAPHY; GANGLION-CELL DISTRIBUTION; VISUAL EVOKED-RESPONSE; FLASH ELECTRORETINOGRAM; OSCILLATORY POTENTIALS; MAGNIFICATION FACTORS; PATTERN ERG; FIELD LOSS; EYES; MONKEYS;
D O I
10.1016/j.ajo.2010.09.018
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To investigate in open-angle glaucoma the focal macular photopic negative response and spectral-domain optical coherence tomography measurements of retinal thicknesses in the superior and inferior macula. DESIGN: Comparative case series. METHODS: We studied 63 eyes of 63 patients with open-angle glaucoma and 41 normal eyes of 41 volunteers. Photopic negative responses were recorded using a spotlight (diameter of 15 degrees of circle), projected onto the whole or superior or inferior macula. Ganglion cell complex (nerve fiber + ganglion cell + inner plexiform layers) thickness was measured using spectral-domain optical coherence tomography. RESULTS: Mean photopic negative response amplitude over the entire macula was significantly (P < .001) decreased compared with that of controls in eyes with early (n = 24; to 62.1%), moderate (n = 21; to 57.2%), and severe (n = 18; to 49.3%) open-angle glaucoma, but not significantly different among eyes with various stages of glaucoma. Mean ganglion cell complex thickness was significantly (P < .001) decreased compared with that of controls in eyes with early (86.0%), moderate (78.3%), and severe (71.2%) glaucoma, and thinning correlated positively with glaucoma severity (P < .001). Mean photopic negative response amplitude correlated significantly (P < .001) with ganglion cell complex thickness over the whole, superior, and inferior macular areas (r = 0.57 to 0.74). In 16 eyes without visual field defect in the inferior hemifield, mean photopic negative response amplitude was 56.5% of normal (P < .001), and mean ganglion cell complex thickness in the superior macula was 92.1% of normal (P = .004). CONCLUSIONS: Focal macular photopic negative response amplitude correlates with ganglion cell complex thickness, but decreases more abruptly in early glaucoma compared with ganglion cell complex thickness. (Am J Ophthalmol 2011;151:494-506. (C) 2011 by Elsevier Inc. All rights reserved.)
引用
收藏
页码:494 / 506
页数:13
相关论文
共 40 条
[1]   EVALUATION OF METHODS FOR AUTOMATED HEMIFIELD ANALYSIS IN PERIMETRY [J].
ASMAN, P ;
HEIJL, A .
ARCHIVES OF OPHTHALMOLOGY, 1992, 110 (06) :820-826
[2]   GLAUCOMA HEMIFIELD TEST - AUTOMATED VISUAL-FIELD EVALUATION [J].
ASMAN, P ;
HEIJL, A .
ARCHIVES OF OPHTHALMOLOGY, 1992, 110 (06) :812-819
[3]   The photopic negative response of the flash electroretinogram in retinal vein occlusion [J].
Chen, Hongling ;
Wu, Dezheng ;
Huang, Shizhou ;
Yan, Hong .
DOCUMENTA OPHTHALMOLOGICA, 2006, 113 (01) :53-59
[4]  
Colotto A, 2000, INVEST OPHTH VIS SCI, V41, P2205
[5]   TOPOGRAPHY OF GANGLION-CELLS IN HUMAN RETINA [J].
CURCIO, CA ;
ALLEN, KA .
JOURNAL OF COMPARATIVE NEUROLOGY, 1990, 300 (01) :5-25
[6]  
Drasdo N, 2001, INVEST OPHTH VIS SCI, V42, P1266
[7]   EARLY DETECTION OF GLAUCOMA BY LONGITUDINAL MONITORING OF THE OPTIC DISK STRUCTURE [J].
FUNK, J .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 1991, 229 (01) :57-61
[8]  
GRAHAM SL, 1994, INVEST OPHTH VIS SCI, V35, P3347
[9]  
Harwerth RS, 1999, INVEST OPHTH VIS SCI, V40, P2242
[10]   SIMULTANEOUS RECORDING OF ELECTRORETINOGRAM AND VISUAL EVOKED-RESPONSE - FOCAL STIMULATION UNDER DIRECT OBSERVATION [J].
HIROSE, T ;
MIYAKE, Y ;
HARA, A .
ARCHIVES OF OPHTHALMOLOGY, 1977, 95 (07) :1205-1208