Determination of Tetracyclines in Bovine and Human Urine using a Graphite-Polyurethane Composite Electrode

被引:32
作者
Fioramonti Calixto, Carolina Maria [1 ]
Gomes Cavalheiro, Eder Tadeu [1 ]
机构
[1] Univ Sao Paulo, Inst Quim Sao Carlos, BR-13566590 Sao Carlos, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
Graphite-polyurethane composite electrode; Oxytetracycline; Human urine analysis; Tetracycline; Bovine urine analysis; PERFORMANCE LIQUID-CHROMATOGRAPHY; TANDEM MASS-SPECTROMETRY; GLASSY-CARBON ELECTRODE; PULSED AMPEROMETRIC DETECTION; FLOW-INJECTION ANALYSIS; VOLTAMMETRIC DETERMINATION; ELECTROCHEMICAL DETERMINATION; IONIC LIQUID; OXYTETRACYCLINE; FILM;
D O I
10.1080/00032719.2014.984194
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The performance of a bare graphite-polyurethane composite electrode (60 percent graphite, m/m) for the determination of tetracycline in human urine and oxytetracycline in human and bovine urine was evaluated. Using optimized differential pulse voltammetry, limits of detection as low as 2.6 micromoles per liter (tetracycline) and 1.7 micromoles per liter (oxytetracycline) were found in phosphate buffer at pH 2.5. The sample preparation included acidification and centrifugation to remove solid proteins followed by direct analysis. Recoveries between 96 and 100 percent were obtained for the determination of tetracycline and oxytetracycline in fortified urine.
引用
收藏
页码:1454 / 1464
页数:11
相关论文
共 39 条
[1]   Oxytetracycline nanosensor based on poly-ortho-aminophenol/multi-walled carbon nanotubes composite film [J].
Ajami, Narges ;
Panah, Niloufar Bahrami ;
Danaee, Iman .
IRANIAN POLYMER JOURNAL, 2014, 23 (02) :121-126
[2]   Voltammetric behavior and square-wave voltammetric determination of cefotaxime in urine [J].
Aleksic, Mara M. ;
Kapetanovic, Vera .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2006, 593 (1-2) :258-266
[3]  
[Anonymous], 1993, Statistics for Analytical Chemistry
[4]   Determination of tetracyclines in multi-specie animal tissues by pressurized liquid extraction and liquid chromatography-tandem mass spectrometry [J].
Blasco, Cristina ;
Di Corcia, Antonio ;
Pico, Yolanda .
FOOD CHEMISTRY, 2009, 116 (04) :1005-1012
[5]  
Calixto CMF, 2012, J BRAZIL CHEM SOC, V23, P938, DOI 10.1590/S0103-50532012000500020
[6]   Flow injection analysis of doxycycline or chlortetracycline in pharmaceutical formulations with pulsed amperometric detection [J].
Charoenraks, T ;
Palaharn, S ;
Grudpan, K ;
Siangproh, W ;
Chailapakul, O .
TALANTA, 2004, 64 (05) :1247-1252
[7]   ANODIC-OXIDATION OF SOME TETRACYCLINES [J].
CHATTEN, LG ;
FLEISCHMANN, M ;
PLETCHER, D .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1979, 102 (03) :407-413
[8]   A confirmatory method for the determination of tetracyclines in muscle using high-performance liquid chromatography with diode-array detection [J].
Cristofani, Elisa ;
Antonini, Chiara ;
Tovo, Gloria ;
Fioroni, Laura ;
Piersanti, Arianna ;
Galarini, Roberta .
ANALYTICA CHIMICA ACTA, 2009, 637 (1-2) :40-46
[9]   Simultaneous determination of tetracycline, oxytetracycline, and 4-epitetracycline in milk by high-performance liquid chromatography [J].
Fritz, Johnathan William ;
Zuo, Yuegang .
FOOD CHEMISTRY, 2007, 105 (03) :1297-1301
[10]   ADSORPTIVE STRIPPING VOLTAMMETRIC DETERMINATION OF TETRACYCLINE AND OXYTETRACYCLINE [J].
GHANDOUR, MA ;
ALI, AMM .
ANALYTICAL LETTERS, 1991, 24 (12) :2171-2186