Characterization of intraocular lenses: a comparison of different measurement methods

被引:2
|
作者
Cherrier, M. [1 ]
Erichsen, I. [1 ]
Krey, S. [1 ]
机构
[1] Trioptics GmbH, D-22880 Wedel, Germany
关键词
Intraocular Lenses; IOL; Shack-Hartmann; Wavefront; ISO; 11979; MTF; Power; Power map; EFL; Diopter; Model Eye;
D O I
10.1117/12.843665
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
One of the most commonly performed ophthalmic surgeries is the replacement of the eye lens by a synthetic intraocular lens. Because of the trend to match the intraocular lens with the properties of the individual eye, intricate designs for IOLs have been developed. Multifocal, diffractive as well as aspheric designs demand for elaborate measurement and analysis options. Various measurement methods have evolved including techniques which analyze the image itself or the emerging wavefront. In order to understand the advantages of these different methods intraocular lenses of various designs have been measured and analyzed under miscellaneous conditions. Measurement results of this comparison will be presented.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] Characterization of diffractive bifocal intraocular lenses
    Damian Mendroch
    Stefan Altmeyer
    Uwe Oberheide
    Scientific Reports, 13
  • [42] Measurement and prediction of the postoperative anterior chamber depth for intraocular lenses of different shape and material
    Haigis, W
    Kammann, J
    Dornbach, G
    Schuttrumpf, R
    ULTRASONOGRAPHY IN OPHTHALMOLOGY XV, 1997, 61 : 437 - 447
  • [43] Comparison of different measurement methods of cGMP
    Kremser, Marcel
    Winkler, Steffen
    Eitner, Frank
    Benardeau, Agnes
    Kraehling, Jan
    JOURNAL OF TRANSLATIONAL MEDICINE, 2019, 17 (01)
  • [44] Comparison of different measurement methods of magnetostriction
    Haraki, T
    Ishida, K
    Matsumura, Y
    Fujita, M
    Kuji, T
    Uchida, H
    SMART STRUCTURES, DEVICES, AND SYSTEMS, 2002, 4935 : 361 - 368
  • [45] Comparison of visual function following implantation of Acrysof Natural intraocular lenses with conventional intraocular lenses
    Landers, John
    Tan, Teng-Han
    Yuen, Joshua
    Liu, Henry
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2007, 35 (02): : 152 - 159
  • [46] A comparison of the visual performance of refractive rotationally asymmetric multifocal intraocular lenses and trifocal intraocular lenses
    Qiu, Jing-Jing
    Zhang, Qian
    Fu, Shu-Hua
    Huang, Jun-Qi
    Wang, Zhi-Hong
    You, Zhi-Peng
    Liu, Fei
    Sun, Tao
    MATERIALS EXPRESS, 2023, 13 (06) : 1110 - 1115
  • [47] Comparison of astigmatic prediction errors associated with new calculation methods for toric intraocular lenses
    Ferreira, Tiago B.
    Ribeiro, Paulo
    Ribeiro, Filomena J.
    O'Neill, Joao G.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2017, 43 (03): : 340 - 347
  • [48] BIOCOMPATIBILITY OF INTRAOCULAR LENSES WITH DIFFERENT SURFACE MODIFICATIONS
    AKIMOTO, A
    YOSHIMURA, N
    TANAKA, T
    MIYAMURA, M
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1995, 36 (04) : S809 - S809
  • [49] Comparison of the optical behaviour of five different multifocal diffractive intraocular lenses in a model eye
    Can, Efe
    Senel, Esat Can
    Holmstroem, Sven T. S.
    Pinero, David P.
    SCIENTIFIC REPORTS, 2023, 13 (01):
  • [50] Comparison of wavefront aberrations and optical quality of eyes implanted with five different intraocular lenses
    Bellucci, R
    Morselli, S
    Piers, P