Characterization of intraocular lenses: a comparison of different measurement methods

被引:2
|
作者
Cherrier, M. [1 ]
Erichsen, I. [1 ]
Krey, S. [1 ]
机构
[1] Trioptics GmbH, D-22880 Wedel, Germany
关键词
Intraocular Lenses; IOL; Shack-Hartmann; Wavefront; ISO; 11979; MTF; Power; Power map; EFL; Diopter; Model Eye;
D O I
10.1117/12.843665
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
One of the most commonly performed ophthalmic surgeries is the replacement of the eye lens by a synthetic intraocular lens. Because of the trend to match the intraocular lens with the properties of the individual eye, intricate designs for IOLs have been developed. Multifocal, diffractive as well as aspheric designs demand for elaborate measurement and analysis options. Various measurement methods have evolved including techniques which analyze the image itself or the emerging wavefront. In order to understand the advantages of these different methods intraocular lenses of various designs have been measured and analyzed under miscellaneous conditions. Measurement results of this comparison will be presented.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Comparison of three different methods for calculation of posterior chamber intraocular lenses.
    Remsch, H
    Kampmeier, J
    Lang, GE
    Lang, GK
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2001, 42 (04) : S13 - S13
  • [2] Comparison of two different devices to assess intraocular lenses
    Furlan, Walter D.
    Remon, Laura
    Llorens, Clara
    Rodriguez-Vallejo, Manuel
    Monsoriu, Juan A.
    OPTIK, 2016, 127 (20): : 10108 - 10114
  • [3] Comparison of Different Wavefront Measurement Setups to Judge the Position Tolerance of Intraocular Lenses in a Model Eye
    Traxler, Lukas
    Reutterer, Bernd
    Bayer, Natascha
    Drauschke, Andreas
    BIOMEDICAL IMAGING AND SENSING CONFERENCE, 2017, 10251
  • [4] Comparison of intraocular lenses
    Dick, HB
    Augustin, AJ
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2001, 218 (07) : 469 - 478
  • [5] COMPARISON OF 2 METHODS OF CALCULATING THE REFRACTIVE POWER OF INTRAOCULAR LENSES
    JANKA, C
    DAXECKER, F
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 1984, 185 (05) : 432 - 433
  • [6] A COMPARISON OF CONTRAST SENSITIVITY TEST METHODS FOR MULTIFOCAL INTRAOCULAR LENSES
    ODONOGHUE, E
    KELLY, S
    NACER, M
    STOREY, J
    MURRAY, I
    MCLEOD, D
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1991, 32 (04) : 1281 - 1281
  • [7] Comparison of clinical outcomes with three different aspheric intraocular lenses
    Lee, Kyung-Min
    Park, Shin-Hae
    Joo, Choun-Ki
    ACTA OPHTHALMOLOGICA, 2011, 89 (01) : 40 - 46
  • [8] Comparison of the Ultraviolet Light Filtering across Different Intraocular Lenses
    Carmen Garcia-Domene, Mari
    Perez-Vives, Caridad
    Peris-Martinez, Cristina
    Maria Artigas, Jose
    OPTOMETRY AND VISION SCIENCE, 2018, 95 (12) : 1129 - 1134
  • [9] Comparison of postoperative surface light scattering of different intraocular lenses
    Miyata, K.
    Otani, S.
    Nejima, R.
    Miyai, T.
    Samejima, T.
    Honbo, M.
    Minami, K.
    Amano, S.
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2009, 93 (05) : 684 - 687
  • [10] Comparison of visual outcomes between bilateral trifocal intraocular lenses and combined bifocal intraocular lenses with different near addition
    Ken Hayashi
    Tatsuhiko Sato
    Chizuka Igarashi
    Motoaki Yoshida
    Japanese Journal of Ophthalmology, 2019, 63 : 429 - 436