Gold nanocluster-based fluorescence biosensor for targeted imaging in cancer cells and ratiometric determination of intracellular pH

被引:126
作者
Ding, Changqin [1 ]
Tian, Yang [1 ,2 ]
机构
[1] Tongji Univ, Dept Chem, Shanghai 200092, Peoples R China
[2] E China Normal Univ, Dept Chem, Shanghai 200062, Peoples R China
关键词
Au nanoclusters; Ratiometric fluorescence biosensor; pH determination; Targeted imaging; Cancer cells; Folate receptor; LIVING CELLS; FOLATE; RECEPTOR; NANOPARTICLES; PROTEIN; PROBE; DELIVERY; SENSOR; ANION; FRET;
D O I
10.1016/j.bios.2014.10.034
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The dysregulated pH is working as a mark of cancer. It is a challenge for developing a biosensor for targeted imaging in cancer cells and monitoring of intracellular pH. Here, a ratiometric fluorescence biosensor for pH determination was developed with targeted imaging into folate acceptor (FR)-rich cancer cells at the same time. AuNCs protected by bovine serum albumin (BSA) worked as reference fluorophore and fluorescein-isothiocyanate (FITC) acted as the response signal for pH. For targeted imaging of cancer cells, the AuNCs were simultaneously conjugated with folic acid (FA). The developed ratiometric biosensor can monitor pH with a wide linear range from 6.0-7.8 with a pKa at 6.84. Under every different pH condition, the probe showed high selectivity over various metal ions and amino acids with its fluorescence ratio stayed almost constant ( < 5%). It also showed good cyclic accuracy when pH switched between 6.0 and 8.0, as well as low cytotoxicity. The AuNC-based inorganic-organic nanohybrid biosensor showed good cell-permeability, low cytotoxicity, and long-term photostability. Accordingly, the pH biosensor was employed to gain targeted imaging in FR+ve Hela cells with FR-ve lung carcinoma cells A549 as comparison, and achieved to monitor the pH changes in Hela cells. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:183 / 190
页数:8
相关论文
共 50 条
[31]   Site-specific fabrication of gold nanocluster-based fluorescence photoswitch enabled by the dual roles of albumin proteins [J].
Zhong, Wencheng ;
Yan, Xiaojian ;
Qu, Shaohua ;
Shang, Li .
AGGREGATE, 2023, 4 (01)
[32]   ESIPT-based ratiometric fluorescence probe for the intracellular imaging of peroxynitrite [J].
Wu, Luling ;
Wang, Yang ;
Weber, Maria ;
Liu, Liyuan ;
Sedgwick, Adam C. ;
Bull, Steven D. ;
Huang, Chusen ;
James, Tony D. .
CHEMICAL COMMUNICATIONS, 2018, 54 (71) :9953-9956
[33]   A Tunable Ratiometric pH Sensor Based on Carbon Nanodots for the Quantitative Measurement of the Intracellular pH of Whole Cells [J].
Shi, Wen ;
Li, Xiaohua ;
Ma, Huimin .
ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2012, 51 (26) :6432-6435
[34]   Mitochondria-Targeted Ratiometric Fluorescent Nanosensor for Simultaneous Biosensing and Imaging of O2•- and pH in Live Cells [J].
Huang, Hong ;
Dong, Fangyuan ;
Tian, Yang .
ANALYTICAL CHEMISTRY, 2016, 88 (24) :12294-12302
[35]   Ratiometric fluorescence detection of Hg2+ based on gold nanocluster/carbon quantum dots nanohybrids [J].
Chen, Junyu ;
Tian, Rui ;
Li, Duo ;
Sun, Xuehua ;
Li, Haoyu ;
Zhang, Yuecheng .
ANALYTICAL METHODS, 2024, 16 (06) :884-891
[36]   Synthesis of gold nanocluster- loaded lysozyme nanoparticles for label- free ratiometric fluorescent pH sensing: applications to enzyme- substrate systems and cellular imaging [J].
Chandirasekar, Shanmugam ;
You, Jyun-Guo ;
Xue, Jhe-Hong ;
Tseng, Wei-Lung .
JOURNAL OF MATERIALS CHEMISTRY B, 2019, 7 (24) :3876-3883
[37]   Determination of dopamine based on its enhancement of gold-silver nanocluster fluorescence [J].
Zhou, Ting ;
Su, Zhu ;
Tu, Yifeng ;
Yan, Jilin .
SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2021, 252
[38]   A Mitochondria-Targeted Ratiometric Biosensor for pH Monitoring and Imaging in Living Cells with Congo-Red-Functionalized Dual-Emission Semiconducting Polymer Dots [J].
Sun, Junyong ;
Ling, Pinghua ;
Gao, Feng .
ANALYTICAL CHEMISTRY, 2017, 89 (21) :11703-11710
[39]   Ratiometric Fluorescence Probe for Monitoring Hydroxyl Radical in Live Cells Based on Gold Nanoclusters [J].
Zhuang, Mei ;
Ding, Changqin ;
Zhu, Anwei ;
Tian, Yang .
ANALYTICAL CHEMISTRY, 2014, 86 (03) :1829-1836
[40]   Amino-coumarin based fluorescence ratiometric sensors for acidic pH and their application for living cells imaging [J].
Long, Lingliang ;
Li, Xiufen ;
Zhang, Dongdong ;
Meng, Suci ;
Zhang, Jinfang ;
Sun, Xianglan ;
Zhang, Chi ;
Zhou, Liping ;
Wang, Lin .
RSC ADVANCES, 2013, 3 (30) :12204-12209