Improving the use of principal component analysis to reduce physiological noise and motion artifacts to increase the sensitivity of task-based fMRI

被引:17
作者
Soltysik, David A. [1 ]
Thomasson, David [2 ]
Rajan, Sunder [1 ]
Biassou, Nadia [3 ]
机构
[1] US FDA, Ctr Devices & Radiol Hlth, Div Biomed Phys, Off Med Prod & Tobacco,Off Sci & Engn Labs, Silver Spring, MD 20993 USA
[2] NIAID, Integrated Res Facil, Ft Detrick, MD 21702 USA
[3] NIH, Warren Grant Magnuson Clin Ctr, Bethesda, MD 20892 USA
基金
美国国家卫生研究院;
关键词
BOLD fMRI; Physiological noise; Principal components analysis; FUNCTIONAL CONNECTIVITY; SIGNAL; BRAIN; BOLD; FLUCTUATIONS; ACTIVATION; STRATEGIES;
D O I
10.1016/j.jneumeth.2014.11.015
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Background: Functional magnetic resonance imaging (fMRI) time series are subject to corruption by many noise sources, especially physiological noise and motion. Researchers have developed many methods to reduce physiological noise, including RETROICOR, which retroactively removes cardiac and respiratory waveforms collected during the scan, and CompCor, which applies principal components analysis (PCA) to remove physiological noise components without any physiological monitoring during the scan. New method: We developed four variants of the CompCor method. The optimized CompCor method applies PCA to time series in a noise mask, but orthogonalizes each component to the BOLD response waveform and uses an algorithm to determine a favorable number of components to use as "nuisance regressors." Whole brain component correction (WCompCor) is similar, except that it applies PCA to time-series throughout the whole brain. Low-pass component correction (LCompCor) identifies low-pass filtered components throughout the brain, while high-pass component correction (HCompCor) identifies high-pass filtered components. Comparison with existing method: We compared the new methods with the original CompCor method by examining the resulting functional contrast-to-noise ratio (CNR), sensitivity, and specificity. Results: (1) The optimized CompCor method increased the CNR and sensitivity compared to the original CompCor method and (2) the application of WCompCor yielded the best improvement in the CNR and sensitivity. Conclusions:The sensitivity of the optimized CompCor,WCompCor, and LCompCor methods exceeded that of the original CompCor method. However, regressing noise signals showed a paradoxical consequence of reducing specificity for all noise reduction methods attempted. Published by Elsevier B.V.
引用
收藏
页码:18 / 29
页数:12
相关论文
共 50 条
  • [1] [Anonymous], 1993, Proceedings of Twelfth Scientific Meeting of the Society for Magnetic Resonance in Medicine, page
  • [2] [Anonymous], 1999, Magnetic Resonance Imaging: Physical Principles and Sequence Design
  • [3] Adaptive cyclic physiologic noise modeling and correction in functional MRI
    Beall, Erik B.
    [J]. JOURNAL OF NEUROSCIENCE METHODS, 2010, 187 (02) : 216 - 228
  • [4] A component based noise correction method (CompCor) for BOLD and perfusion based fMRI
    Behzadi, Yashar
    Restom, Khaled
    Liau, Joy
    Liu, Thomas T.
    [J]. NEUROIMAGE, 2007, 37 (01) : 90 - 101
  • [5] Sources of functional magnetic resonance imaging signal fluctuations in the human brain at rest: a 7 T study
    Bianciardi, Marta
    Fukunaga, Masaki
    van Gelderen, Peter
    Horovitz, Silvina G.
    de Zwart, Jacco A.
    Shmueli, Karin
    Duyn, Jeff H.
    [J]. MAGNETIC RESONANCE IMAGING, 2009, 27 (08) : 1019 - 1029
  • [6] Making the most of fMRI at 7 T by suppressing spontaneous signal fluctuations
    Bianciardi, Marta
    van Gelderen, Peter
    Duyn, Jeff H.
    Fukunaga, Masaki
    de Zwart, Jacco A.
    [J]. NEUROIMAGE, 2009, 44 (02) : 448 - 454
  • [7] Experimental designs and processing strategies for fMRI studies involving overt verbal responses
    Birn, RM
    Cox, RW
    Bandettini, PA
    [J]. NEUROIMAGE, 2004, 23 (03) : 1046 - 1058
  • [8] Birn RM, 1999, HUM BRAIN MAPP, V7, P106, DOI 10.1002/(SICI)1097-0193(1999)7:2<106::AID-HBM4>3.3.CO
  • [9] 2-F
  • [10] Separating respiratory-variation-related neuronal-activity-related fluctuations in fluctuations from fMRI
    Birn, RM
    Diamond, JB
    Smith, MA
    Bandettini, PA
    [J]. NEUROIMAGE, 2006, 31 (04) : 1536 - 1548