Prospective study of 1308 nasopharyngeal swabs from 1033 patients using the LUMIPULSE SARS-CoV-2 antigen test: Comparison with RT-qPCR

被引:38
作者
Hirotsu, Yosuke [1 ]
Maejima, Makoto [2 ]
Shibusawa, Masahiro [2 ]
Amemiya, Kenji [3 ]
Nagakubo, Yuki [2 ,3 ]
Hosaka, Kazuhiro [2 ]
Sueki, Hitomi [2 ]
Hayakawa, Miyoko [4 ]
Mochizuki, Hitoshi [1 ,4 ,5 ]
Tsutsui, Toshiharu [6 ]
Kakizaki, Yumiko [6 ]
Miyashita, Yoshihiro [6 ]
Omata, Masao [5 ,7 ]
机构
[1] Yamanashi Cent Hosp, Genome Anal Ctr, 1-1-1 Fujimi, Kofu, Yamanashi, Japan
[2] Yamanashi Cent Hosp, Div Microbiol Clin Lab, Kofu, Yamanashi, Japan
[3] Yamanashi Cent Hosp, Div Genet & Clin Lab, Kofu, Yamanashi, Japan
[4] Yamanashi Cent Hosp, Cent Clin Lab, Kofu, Yamanashi, Japan
[5] Yamanashi Cent Hosp, Dept Gastroenterol, Kofu, Yamanashi, Japan
[6] Yamanashi Cent Hosp, Lung Canc & Resp Dis Ctr, Kofu, Yamanashi, Japan
[7] Univ Tokyo, Bunkyo Ku, Tokyo, Japan
基金
日本学术振兴会;
关键词
SARS-CoV-2; COVID-19; Antigen; RT-qPCR; LUMIPULSE;
D O I
10.1016/j.ijid.2021.02.005
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
Background: Reverse transcription polymerase chain reaction (RT-PCR) is the gold standard for detection of severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2). Previously, the accuracy of the quantitative LUMIPULSE SARS-CoV-2 antigen test was demonstrated using samples collected retrospectively. In this study, the LUMIPULSE antigen test was clinically validated using prospective samples. Methods: In total, 1033 nasopharyngeal swab samples were collected from 1033 individuals, and an additional 275 follow-up samples were collected from 43 patients who subsequently tested positive for coronavirus disease 2019 (COVID-19). All 1308 samples were subjected to quantitative RT-PCR (RT-qPCR) and the antigen test. The antibody response was investigated for patients with discordant results to clarify if seroconversion had occurred. Results: RT-qPCR identified 990 samples as negative and 43 as positive, while the antigen test identified 992 samples as negative, 37 as positive and four as inconclusive. The overall concordance rate was 99.7% (1026/1029). Sensitivity, specificity, positive predictive value and negative predictive value of the antigen test were 92.5% (37/40), 100% (989/989), 100% (37/37) and 99.7% (989/992), respectively, after exclusion of the four inconclusive results. The kappa coefficient was 0.960 (95% confidence interval 0.892-0.960), suggesting excellent agreement between the two tests. Seropositivity in five of seven patients with discordant results suggested that the discrepancy was caused by samples collected during the late phase of infection. Using follow-up samples, correlation was observed between the antigen level and the viral load or cycle threshold value. The concordance rate between these test results tended to be high among samples collected 0-9 days after symptom onset, but this decreased gradually in samples collected thereafter. Conclusions: This prospective study demonstrated that the LUMIPULSE antigen test is a highly accurate diagnostic test for SARS-CoV-2. (C) 2021 The Author(s). Published by Elsevier Ltd on behalf of International Society for Infectious Diseases.
引用
收藏
页码:7 / 14
页数:8
相关论文
共 30 条
[1]  
[Anonymous], 2021, CLIN MICROBIOL INFEC, DOI DOI 10.1016/J.CMI.2020.11.004
[2]   Predicting Infectious Severe Acute Respiratory Syndrome Coronavirus 2 From Diagnostic Samples [J].
Bullard, Jared ;
Dust, Kerry ;
Funk, Duane ;
Strong, James E. ;
Alexander, David ;
Garnett, Lauren ;
Boodman, Carl ;
Bello, Alexander ;
Hedley, Adam ;
Schiffman, Zachary ;
Doan, Kaylie ;
Bastien, Nathalie ;
Li, Yan ;
Van Caeseele, Paul G. ;
Poliquin, Guillaume .
CLINICAL INFECTIOUS DISEASES, 2020, 71 (10) :2663-2666
[3]   Urgent need of rapid tests for SARS CoV-2 antigen detection: Evaluation of the SD-Biosensor antigen test for SARS-CoV-2 [J].
Cerutti, Francesco ;
Burdino, Elisa ;
Milia, Maria Grazia ;
Allice, Tiziano ;
Gregori, Gabriella ;
Bruzzone, Bianca ;
Ghisetti, Valeria .
JOURNAL OF CLINICAL VIROLOGY, 2020, 132
[4]   Detection of 2019 novel coronavirus (2019-nCoV) by real-time RT-PCR (Publication with Expression of Concern) [J].
Corman, Victor M. ;
Landt, Olfert ;
Kaiser, Marco ;
Molenkamp, Richard ;
Meijer, Adam ;
Chu, Daniel K. W. ;
Bleicker, Tobias ;
Bruenink, Sebastian ;
Schneider, Julia ;
Schmidt, Marie Luisa ;
Mulders, Daphne G. J. C. ;
Haagmans, Bart L. ;
van der Veer, Bas ;
van den Brink, Sharon ;
Wijsman, Lisa ;
Goderski, Gabriel ;
Romette, Jean-Louis ;
Ellis, Joanna ;
Zambon, Maria ;
Peiris, Malik ;
Goossens, Herman ;
Reusken, Chantal ;
Koopmans, Marion P. G. ;
Drosten, Christian .
EUROSURVEILLANCE, 2020, 25 (03) :23-30
[5]  
Fujirebio, 2020, FUJ EUR ANN CE MARK
[6]  
Fujirebio, 2020, FUJ EUR CENTOGENE EN
[7]   Analysis of a persistent viral shedding patient infected with SARS-CoV-2 by RT-qPCR, FilmArray Respiratory Panel v2.1, and antigen detection [J].
Hirotsu, Yosuke ;
Maejima, Makoto ;
Shibusawa, Masahiro ;
Amemiya, Kenji ;
Nagakubo, Yuki ;
Hosaka, Kazuhiro ;
Sueki, Hitomi ;
Hayakawa, Miyoko ;
Mochizuki, Hitoshi ;
Tsutsui, Toshiharu ;
Kakizaki, Yumiko ;
Miyashita, Yoshihiro ;
Omata, Masao .
JOURNAL OF INFECTION AND CHEMOTHERAPY, 2021, 27 (02) :406-409
[8]   Pooling RT-qPCR testing for SARS-CoV-2 in 1000 individuals of healthy and infection-suspected patients [J].
Hirotsu, Yosuke ;
Maejima, Makoto ;
Shibusawa, Masahiro ;
Nagakubo, Yuki ;
Hosaka, Kazuhiro ;
Amemiya, Kenji ;
Sueki, Hitomi ;
Hayakawa, Miyoko ;
Mochizuki, Hitoshi ;
Tsutsui, Toshiharu ;
Kakizaki, Yumiko ;
Miyashita, Yoshihiro ;
Omata, Masao .
SCIENTIFIC REPORTS, 2020, 10 (01)
[9]   Comparison of automated SARS-CoV-2 antigen test for COVID-19 infection with quantitative RT-PCR using 313 nasopharyngeal swabs, including from seven serially followed patients [J].
Hirotsu, Yosuke ;
Maejima, Makoto ;
Shibusawa, Masahiro ;
Nagakubo, Yuki ;
Hosaka, Kazuhiro ;
Amemiya, Kenji ;
Sueki, Hitomi ;
Hayakawa, Miyoko ;
Mochizuki, Hitoshi ;
Tsutsui, Toshiharu ;
Kakizaki, Yumiko ;
Miyashita, Yoshihiro ;
Yagi, Shintaro ;
Kojima, Satoshi ;
Omata, Masao .
INTERNATIONAL JOURNAL OF INFECTIOUS DISEASES, 2020, 99 :397-402
[10]   Double-quencher probes improve detection sensitivity toward Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) in a reverse-transcription polymerase chain reaction (RT-PCR) assay [J].
Hirotsu, Yosuke ;
Mochizuki, Hitoshi ;
Omata, Masao .
JOURNAL OF VIROLOGICAL METHODS, 2020, 284