Fault detection in closed-loop systems using a double residual generator

被引:0
|
作者
Niemann, Henrik [1 ]
Poulsen, Niels Kjolstad [2 ]
机构
[1] Tech Univ Denmark, Dept Elect Engn, DK-2800 Lyngby, Denmark
[2] Tech Univ Denmark, Dept Appl Math & Comp Sci, DK-2800 Lyngby, Denmark
来源
IFAC PAPERSONLINE | 2022年 / 55卷 / 06期
关键词
Fault detection; residual generators; parametric faults; closed-loop systems; coprime factorization; DIAGNOSIS; DESIGN;
D O I
10.1016/j.ifacol.2022.07.145
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
A double residual generator for fault detection in closed-loop systems is presented in this paper. The residual generator gives the standard residual vector and a dual residual vector as outputs. The standard residual vector can be applied directly for fault detection. The dual residual vector depends on known inputs to the system e.g. reference inputs and auxiliary inputs but decoupled from the disturbance in the system. It is also an input vector that can be applied for active fault detection (AFD). The dual residual vector can be considered as a generalized input vector in connection with AFD in closed-loop systems. This gives the possibility to use all known inputs for detection. The dual residual vector gives a link between passive and AFD in closed-loop systems. The double residual generator is given directly as the left Bezout matrix from the Bezout equation. Copyright (C) 2022 The Authors.
引用
收藏
页码:298 / 303
页数:6
相关论文
共 50 条
  • [1] Closed-loop fault detection using the local approach
    Cheng, LL
    Kwok, KE
    Huang, B
    CANADIAN JOURNAL OF CHEMICAL ENGINEERING, 2003, 81 (05): : 1101 - 1108
  • [2] Robust Fault Detection and Estimation of Sensor Fault for Closed-loop Control Systems
    Zhang, Yang
    Wang, Shaoping
    Shi, Jian
    2020 IEEE/ASME INTERNATIONAL CONFERENCE ON ADVANCED INTELLIGENT MECHATRONICS (AIM), 2020, : 1155 - 1160
  • [3] Fault detection and identification for wind turbine systems: a closed-loop analysis
    Donders, S.
    Verdult, V.
    Verhaegen, M.
    PROCEEDINGS OF ISMA 2004: INTERNATIONAL CONFERENCE ON NOISE AND VIBRATION ENGINEERING, VOLS 1-8, 2005, : 2619 - 2630
  • [4] Estimation of Parametric Fault in Closed-loop Systems
    Niemann, Henrik
    Poulsen, Niels Kjolstad
    2015 AMERICAN CONTROL CONFERENCE (ACC), 2015, : 201 - 206
  • [5] Fault Detection for Closed-Loop Control Systems Based on Parity Space Transformation
    Sun, Bowen
    Wang, Jiongqi
    He, Zhangming
    Qin, Yongrui
    Wang, Dayi
    Zhou, Haiyin
    IEEE ACCESS, 2019, 7 : 75153 - 75165
  • [6] Optimal sensor location in closed-loop control systems for fault detection and isolation
    Xu, YH
    Jin, J
    PROCEEDINGS OF THE 2000 AMERICAN CONTROL CONFERENCE, VOLS 1-6, 2000, : 1195 - 1199
  • [7] Small Fault Detection for a Class of Closed-Loop Systems via Deterministic Learning
    Chen, Tianrui
    Wang, Cong
    Chen, Guo
    Dong, Zhaoyang
    Hill, David J.
    IEEE TRANSACTIONS ON CYBERNETICS, 2019, 49 (03) : 897 - 906
  • [8] Active Robust Fault Detection in Closed-Loop Systems: Quadratic Optimization Approach
    Ashari, Alireza Esna Esna
    Nikoukhah, Ramine
    Campbell, Stephen L.
    IEEE TRANSACTIONS ON AUTOMATIC CONTROL, 2012, 57 (10) : 2532 - 2544
  • [9] Vector based fault isolation in closed-loop systems
    Niemann, Henrik
    Poulsen, Niels Kjolstad
    IFAC PAPERSONLINE, 2024, 58 (04): : 664 - 669
  • [10] Review on fault diagnosis techniques for closed-loop systems
    Zhou, Dong-Hua
    Liu, Yang
    He, Xiao
    Zidonghua Xuebao/Acta Automatica Sinica, 2013, 39 (11): : 1933 - 1943