First Clinical Evaluation of High-Pitch Dual-Source Computed Tomographic Angiography Comparing Automated Tube Potential Selection With Automated Tube Current Modulation

被引:6
作者
Beeres, Martin [1 ]
Williams, Kimberly [1 ]
Bauer, Ralf W. [1 ]
Scholtz, Jan [1 ]
Kaup, Moritz [1 ]
Gruber-Rouh, Tatjana [1 ]
Lee, Clara [1 ]
Wichmann, Julian L. [1 ]
Frellesen, Claudia [1 ]
Nour-Eldin, Nour-Eldin A. [1 ,2 ]
Vogl, Thomas J. [1 ]
Kerl, Josef Matthias [1 ]
Bodelle, Boris [1 ]
机构
[1] Clin Goethe Univ, Dept Diagnost & Intervent Radiol, D-60590 Frankfurt, Germany
[2] Cairo Univ Hosp, Dept Diagnost & Intervent Radiol, Cairo, Egypt
关键词
SOURCE CT; CHEST; 128-SLICE; AORTA;
D O I
10.1097/RCT.0000000000000247
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective To investigate and compare the use of automated tube potential selection (ATPS) with automated tube current modulation (ATCM) in high-pitch dual-source computed tomographic angiography (CTA) for imaging the whole aorta without electrocardiogram synchronization. Methods Two groups of 60 patients underwent CTA on a dual-source computed tomographic device in high-pitch mode: ATCM (with 100-kV fixed tube potential) was used in group 1 and ATPS (with the same image quality options) in group 2. For the evaluation of radiation exposure, CT dose index and dose-length product were analyzed. Contrast and image quality were assessed by 2 independent observers. Results The ATPS group received a higher radiation dose than the ATCM group (P < 0.001) because in 80% of patients, the software switched to use of a 120-kV tube potential. In all cases, images of the aorta were of sufficient quality. Conclusions High-pitch dual-source CTA of the aorta using ATPS is feasible in clinical routine, but is associated with higher radiation exposure than the ATCM protocol. This finding contradicts previously evaluations of ATPS based on single-source techniques.
引用
收藏
页码:624 / 628
页数:5
相关论文
共 21 条
[1]   Detection of Coronary Artery Stenoses by Low-Dose, Prospectively ECG-Triggered, High-Pitch Spiral Coronary CT Angiography [J].
Achenbach, Stephan ;
Goroll, Tobias ;
Seltmann, Martin ;
Pflederer, Tobias ;
Anders, Katharina ;
Ropers, Dieter ;
Daniel, Werner G. ;
Uder, Michael ;
Lell, Michael ;
Marwan, Mohamed .
JACC-CARDIOVASCULAR IMAGING, 2011, 4 (04) :328-337
[2]   Low-dose, 128-slice, dual-source CT coronary angiography: accuracy and radiation dose of the high-pitch and the step-and-shoot mode [J].
Alkadhi, Hatem ;
Stolzmann, Paul ;
Desbiolles, Lotus ;
Baumueller, Stephan ;
Goetti, Robert ;
Plass, Andre ;
Scheffel, Hans ;
Feuchtner, Gudrun ;
Falk, Volkmar ;
Marincek, Borut ;
Leschka, Sebastian .
HEART, 2010, 96 (12) :933-938
[3]   Routine chest and abdominal high-pitch CT: An alternative low dose protocol with preserved image quality [J].
Amacker, Nadja A. ;
Mader, Caecilia ;
Alkadhi, Hatem ;
Leschka, Sebastian ;
Frauenfelder, Thomas .
EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (03) :E392-E397
[4]   Diagnostic image quality of a comprehensive high-pitch dual-spiral cardiothoracic CT protocol in patients with undifferentiated acute chest pain [J].
Bamberg, Fabian ;
Marcus, Roy ;
Sommer, Wieland ;
Schwarz, Florian ;
Nikolaou, Konstantin ;
Becker, Christoph R. ;
Reiser, Maximilian F. ;
Johnson, Thorsten R. C. .
EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (12) :3697-3702
[5]   Energy Limits in Second Generation High-pitch Dual Source CT - Comparison in an Upper Abdominal Phantom [J].
Beeres, Martin ;
Bauer, Ralf W. ;
Kerl, Josef M. ;
Vogl, Thomas J. ;
Lee, Clara .
JOURNAL OF CLINICAL IMAGING SCIENCE, 2015, 5
[6]   Chest-abdomen-pelvis CT for staging in cancer patients: dose effectiveness and image quality using automated attenuation-based tube potential selectionek [J].
Beeres, Martin ;
Roemer, Marcus ;
Bodelle, Boris ;
Lee, Clara ;
Gruber-Rouh, Tatjana ;
Mbalisike, Emmanuel ;
Kerl, Josef M. ;
Wichmann, Julian L. ;
Schulz, Boris ;
Vogl, Thomas J. ;
Bauer, Ralf W. .
CANCER IMAGING, 2014, 14
[7]   High-pitch dual-source CT angiography of the whole aorta without ECG synchronisation: Initial experience [J].
Beeres, Martin ;
Schell, Boris ;
Mastragelopoulos, Aristidis ;
Herrmann, Eva ;
Kerl, Josef Matthias ;
Gruber-Rouh, Tatjana ;
Lee, Clara ;
Siebenhandl, Petra ;
Bodelle, Boris ;
Zangos, Stephan ;
Vogl, Thomas J. ;
Jacobi, Volkmar ;
Bauer, Ralf W. .
EUROPEAN RADIOLOGY, 2012, 22 (01) :129-137
[8]   Topogram-based automated selection of the tube potential and current in thoraco-abdominal trauma CT - a comparison to fixed kV with mAs modulation alone [J].
Frellesen, Claudia ;
Stock, Wenzel ;
Kerl, J. Matthias ;
Lehnert, Thomas ;
Wichmann, Julian L. ;
Nau, Christoph ;
Geiger, Emanuel ;
Wutzler, Sebastian ;
Beeres, Martin ;
Schulz, Boris ;
Bodelle, Boris ;
Ackermann, Hanns ;
Vogl, Thomas J. ;
Bauer, Ralf W. .
EUROPEAN RADIOLOGY, 2014, 24 (07) :1725-1734
[9]   Automated tube potential selection for standard chest and abdominal CT in follow-up patients with testicular cancer: comparison with fixed tube potential [J].
Gnannt, Ralph ;
Winklehner, Anna ;
Eberli, Daniel ;
Knuth, Alexander ;
Frauenfelder, Thomas ;
Alkadhi, Hatem .
EUROPEAN RADIOLOGY, 2012, 22 (09) :1937-1945
[10]   High-Pitch Dual-Source CT Angiography of the Thoracic and Abdominal Aorta: Is Simultaneous Coronary Artery Assessment Possible? [J].
Goetti, Robert ;
Baumueller, Stephan ;
Feuchtner, Gudrun ;
Stolzmann, Paul ;
Karlo, Christoph ;
Alkadhi, Hatem ;
Leschka, Sebastian .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 194 (04) :938-944