Percutaneous screw fixation for the acetabular fracture with quadrilateral plate involved by three-dimensional fluoroscopy navigation: Surgical technique

被引:27
作者
Ruan, Zhiyong [1 ]
Luo, Cong-Feng [1 ]
Zeng, Bing-Fang [1 ]
Zhang, Chang-Qing [1 ]
机构
[1] Shanghai Jiao Tong Univ, Dept Orthopaed, Shanghai Sixth Peoples Hosp, Sch Med, Shanghai 200233, Peoples R China
来源
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED | 2012年 / 43卷 / 04期
关键词
SURGERY; INSERTION; ACCURACY; INJURY; HIP;
D O I
10.1016/j.injury.2011.08.002
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: The percutaneous three-dimensional (3D)-fluoroscopic-navigated screw directing to the quadrilateral plate was attempted. Materials and methods: Five patients with acetabular fractures were treated by 3D navigated percutaneous screw. The quadrilateral plate was involved in all the patients. The Arcadis 3D (ARCADIS Orbic 3D (R); Siemens AG Healthcare Sector, Erlangen, Germany) and computer navigation system (stryker navigation system) were employed, screwing trajectory was attempted to anchor the quadrilateral plate perpendicularly to the fracture line and close to the joint cartilage as much as possible. Parameters including fracture gap closure (P1), distance to the joint cartilage (P2), angulations between the screw and the fracture line (P3), were measured with the software installed on the machine of Arcadis 3D. Result: Seven screws were inserted with the use of 3D fluoroscopic navigation. The quadrilateral plate was hold by percutaneous screws. The closure of fracture gap was achieved in 3 patients by 2-3 mm. The nearest distance from the screw to the joint cartilage was ranged from < 1 mm to 6 mm. The angulations between the screw and the fracture line was 80-90 degrees in three patients, it was 60 degrees and 65 degrees respectively on the rest two patients. All patients felt pain free 1 week after the operation. No complication was noted postoperatively. Conclusion: The surgical technique of percutaneous screwing for the acetabular fracture with three-dimensional fluoroscopy-based navigation was demonstrated. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:517 / 521
页数:5
相关论文
共 26 条
[1]  
Borrelli J, 2005, J ORTHOP TRAUMA, V19, P299
[2]  
Brown GA, 2000, CLIN ORTHOP RELAT R, P219
[3]  
Citak M, 2006, Comput Aided Surg, V11, P209, DOI 10.3109/10929080600890015
[4]   Accuracy analysis of Iso-C3D versus fluoroscopy-based navigated retrograde drilling of osteochondral lesions -: A pilot study [J].
Citak, M. ;
Kendoff, D. ;
Kfuri, M., Jr. ;
Pearle, A. ;
Krettek, C. ;
Huefner, T. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2007, 89B (03) :323-326
[5]   Navigated minimally invasive thoracolumbar pedicle screw placement with flat panel 3-D imaging. A feasibility study [J].
Citak, Musa ;
Stubig, Timo ;
Kendoff, Daniel ;
Citak, Mustafa ;
O'Loughlin, Padhraig F. ;
Huefner, Tobias ;
Krettek, Christian .
TECHNOLOGY AND HEALTH CARE, 2010, 18 (02) :101-110
[6]  
Crowl Adam C, 2002, Comput Aided Surg, V7, P169, DOI 10.1002/igs.10040
[7]   Percutaneous screw fixation of acetabular fractures with 2D fluoroscopy-based computerized navigation [J].
Gao Hong ;
Luo Cong-Feng ;
Hu Cheng-Fang ;
Zhang Chang-Qing ;
Zeng Bing-Fang .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2010, 130 (09) :1177-1183
[8]   2D-fluoroscopic navigated percutaneous screw fixation of pelvic ring injuries - a case series [J].
Gras, Florian ;
Marintschev, Ivan ;
Wilharm, Arne ;
Klos, Kajetan ;
Mueckley, Thomas ;
Hofmann, Gunther O. .
BMC MUSCULOSKELETAL DISORDERS, 2010, 11
[9]   Injury of the femoral nerve associated with acetabular fracture [J].
Gruson, KI ;
Moed, BR .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2003, 85A (03) :428-431
[10]   Iatrogenic nerve injury in acetabular fracture surgery: A comparison of monitored and unmonitored procedures [J].
Haidukewych, GJ ;
Scaduto, J ;
Herscovici, D ;
Sanders, RW ;
DiPasquale, T .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2002, 16 (05) :297-301