摘要
With increasingly fierce competition for jobs, the pressures on people have risen in recent years, leading to lifestyle and diet disorders that result in significantly higher risks of cardiovascular disease. Hypertension is one of the common chronic cardiovascular diseases; however, mainstream blood pressure measurement devices are relatively heavy. When multiple measurements are required, the user experience and the measurement results may be unsatisfactory. In this paper, we describe the design of a signal collection module that collects pulse waves and electrocardiograph (ECG) signals. The collected signals are input into a signal processing module to filter the noise and amplify the useful physiological signals. Then, we use a wavelet transform to eliminate baseline drift noise and detect the feature points of the pulse waves and ECG signals. We propose the concept of detecting the wave shape associated with an instance, an approach that minimizes the impact of atypical pulse waves on blood pressure measurements. Finally, we propose an improved method for measuring blood pressure based on pulse wave velocity that improves the accuracy of blood pressure measurements by 58%. Moreover, the results meet the american medical instrument promotion association standards, which demonstrate the feasibility of our measurement system.
引用
收藏
页码:1 / 14
页数:14
相关论文
共 29 条
[1]  
Ahrabi SS, 2014, 2014 14TH INTERNATIONAL CONFERENCE ON HYBRID INTELLIGENT SYSTEMS (HIS), P315, DOI 10.1109/HIS.2014.7086168
[2]  
[Anonymous], J ELECT DESIGN ENG
[3]   Aortic pulse wave velocity index and mortality in end-stage renal disease [J].
Blacher, J ;
Safar, ME ;
Guerin, AP ;
Pannier, B ;
Marchais, SJ ;
London, GM .
KIDNEY INTERNATIONAL, 2003, 63 (05) :1852-1860
[4]  
Chen TY, 2007, IITA 2007: WORKSHOP ON INTELLIGENT INFORMATION TECHNOLOGY APPLICATION, PROCEEDINGS, P107
[5]   Vehicle Positioning Using 5G Millimeter-Wave Systems [J].
Cui, Xuerong ;
Gulliver, Thomas Aaron ;
Li, Juan ;
Zhang, Hao .
IEEE ACCESS, 2016, 4 :6964-6973
[6]  
Gray JB, 1998, Technometrics, V40, P156
[7]  
Hu Z., 1995, J BIOMED ENG, V12, P162
[8]  
Jiao Xuejun, 2002, Sheng Wu Yi Xue Gong Cheng Xue Za Zhi, V19, P217
[9]  
Kong L.J., 2014, MATLAB WAVELET ANAL
[10]   A METHOD USING INDUCED WAVES TO STUDY PRESSURE PROPAGATION IN HUMAN ARTERIES [J].
LANDOWNE, M .
CIRCULATION RESEARCH, 1957, 5 (06) :594-601