First implantable hemodynamic monitoring device placement in single ventricle fontan anatomy

被引:10
作者
Bradley, Elisa A.
Berman, Darren
Daniels, Curt J.
机构
[1] Ohio State Univ, Columbus, OH 43210 USA
[2] Nationwide Childrens Hosp, Ctr Heart, Columbus, OH USA
关键词
implantable hemodynamic monitor; single ventricle; Fontan; HEART-FAILURE; OPERATION;
D O I
10.1002/ccd.26498
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The Fontan anatomy leads to elevated central venous pressure along with chronic venous congestion and low cardiac output; this is felt to be responsible for deterioration of exercise tolerance and functional capacity over time. Real-time hemodynamic evaluation of the Fontan anatomy has not been evaluated until now. Here, we report the technical aspects of the first two adult Fontan patients to undergo placement of an invasive hemodynamic monitor (IHM). We validate IHM readings with invasive pulmonary artery catheter derived hemodynamics in the Fontan and show successful home transmission of pulmonary artery hemodynamic tracings. This technology has the capacity to change current understanding of Fontan hemodynamics and treatment in patients with complex single-ventricle anatomy. (c) 2016 Wiley Periodicals, Inc.
引用
收藏
页码:248 / 252
页数:5
相关论文
共 10 条
[1]   Wireless pulmonary artery haemodynamic monitoring in chronic heart failure: a randomised controlled trial [J].
Abraham, William T. ;
Adamson, Philip B. ;
Bourge, Robert C. ;
Aaron, Mark F. ;
Costanzo, Maria Rosa ;
Stevenson, Lynne W. ;
Strickland, Warren ;
Neelagaru, Suresh ;
Raval, Nirav ;
Krueger, Steven ;
Weiner, Stanislav ;
Shavelle, David ;
Jeffries, Bradley ;
Yadav, Jay S. .
LANCET, 2011, 377 (9766) :658-666
[2]   Wireless Pulmonary Artery Pressure Monitoring Guides Management to Reduce Decompensation in Heart Failure With Preserved Ejection Fraction [J].
Adamson, Philip B. ;
Abraham, William T. ;
Bourge, Robert C. ;
Costanzo, Maria Rosa ;
Hasan, Ayesha ;
Yadav, Chethan ;
Henderson, John ;
Cowart, Pam ;
Stevenson, Lynne Warner .
CIRCULATION-HEART FAILURE, 2014, 7 (06) :935-944
[3]  
Benza RL, J HEAT LUNG IN PRESS
[4]   Randomized controlled trial of an implantable continuous hemodynamic monitor in patients with advanced heart failure - The COMPASS-HF study [J].
Bourge, Robert C. ;
Abraham, William T. ;
Adamson, Philip B. ;
Aaron, Mark F. ;
Aranda, Juan M., Jr. ;
Magalski, Anthony ;
Zile, Michael R. ;
Smith, Andrew L. ;
Smart, Frank W. ;
O'Shaughnessy, Mark A. ;
Jessup, Mariell L. ;
Sparks, Brandon ;
Naftel, David L. ;
Stevenson, Lynne Warner .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2008, 51 (11) :1073-1079
[5]   SURGICAL REPAIR OF TRICUSPID ATRESIA [J].
FONTAN, F ;
BAUDET, E .
THORAX, 1971, 26 (03) :240-+
[6]   Failure of the Fontan Circulation [J].
Gewillig, Marc ;
Goldberg, David J. .
HEART FAILURE CLINICS, 2014, 10 (01) :105-+
[7]   Natural history of exercise capacity after the Fontan operation: A longitudinal study [J].
Giardini, Alessandro ;
Hager, Alfred ;
Napoleone, Carlo Pace ;
Picchio, Fernando M. .
ANNALS OF THORACIC SURGERY, 2008, 85 (03) :818-822
[8]   Beyond a Broken Heart: Circulatory Dysfunction in the Failing Fontan [J].
Mori, Makoto ;
Aguirre, Alfredo J. ;
Elder, Robert W. ;
Kashkouli, Ali ;
Farris, Alton Brad ;
Ford, Ryan M. ;
Book, Wendy M. .
PEDIATRIC CARDIOLOGY, 2014, 35 (04) :569-579
[9]   A cross-sectional study of exercise performance during the first 2 decades of life after the Fontan operation [J].
Paridon, Stephen M. ;
Mitchell, Paul D. ;
Colan, Steven D. ;
Williams, Richard V. ;
Blaufox, Andrew ;
Li, Jennifer S. ;
Margossian, Renee ;
Mital, Seema ;
Russell, Jennifer ;
Rhodes, Jonathan .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2008, 52 (02) :99-107
[10]   The Precarious State of the Liver After a Fontan Operation: Summary of a Multidisciplinary Symposium [J].
Rychik, Jack ;
Veldtman, Gruschen ;
Rand, Elizabeth ;
Russo, Pierre ;
Rome, Jonathan J. ;
Krok, Karen ;
Goldberg, David J. ;
Cahill, Anne Marie ;
Wells, Rebecca G. .
PEDIATRIC CARDIOLOGY, 2012, 33 (07) :1001-1012