Transient polarity comparison based protection for system with power electronic interfaced distributed generation units

被引:2
作者
Kong, Wei [1 ]
Chen, Z. [2 ]
Bo, Z. Q. [3 ]
Dong, X. Z. [1 ]
Klimek, A. [3 ]
机构
[1] Tsinghua Univ, Dept Elect Engn, Beijing 100084, Peoples R China
[2] Aalborg Univ, Inst Energy Technol, Aalborg, Denmark
[3] AREVA T&D Automat & Informat Syst, Stafford, England
来源
2007 42ND INTERNATIONAL UNIVERSITIES POWER ENGINEERING CONFERENCE, VOLS 1-3 | 2007年
关键词
transient based protection; polarity comparison; power electronics interface; distributed generation units;
D O I
10.1109/UPEC.2007.4469059
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Various distributed generation units (DGs) are connected to utility power grid. With the advances in power electronics technology, many electronics converter interfaces have been utilized in DGs. The power balance control strategies can be achieved by the flexible control modes of the power electronics converter. However, because of the dynamic response and adjustment ability of the electronics converter interface, the disturbance phenomena caused by the faults are not so distinct that the sensitivity and reliability of the relay may be decreased. Ibis paper presents transient polarity comparison based protection for system with power electronics interfaced DGs. The relays are connected to the current transducers (CTs) at both ends of the protected line to extract the fault transient signals. The polarities of the fault transient signals at both ends of the protected line are compared to determine whether a fault is inside or outside the protected line. A typical distribution power system with power electronics interfaced DGs is simulated. Various tests with respect to various fault conditions are conducted. Results show that the presented technique can correctly distinguish between internal and external faults. The technique is simple in application and fast in operation.
引用
收藏
页码:842 / 846
页数:5
相关论文
共 8 条
[1]  
[Anonymous], 2006, Grid support by power electronic converters of Distributed Generation units
[2]   Positional protection of transmission line using fault generated high frequency transient signals [J].
Bo, ZQ ;
Redfern, MA ;
Weller, GC .
IEEE TRANSACTIONS ON POWER DELIVERY, 2000, 15 (03) :888-894
[3]   A new technique for transformer protection based on transient detection [J].
Bo, ZQ ;
Weller, G ;
Lomas, T .
IEEE TRANSACTIONS ON POWER DELIVERY, 2000, 15 (03) :870-875
[4]  
BO ZQ, 1997, DEV POW SYST PROT 6, P227
[5]  
HASSAM FAM, 2005, POWER ELECT INTERFAC
[6]  
Hatziargyriou ND, 2002, 2002 IEEE POWER ENGINEERING SOCIETY WINTER MEETING, VOLS 1 AND 2, CONFERENCE PROCEEDINGS, P1017, DOI 10.1109/PESW.2002.985163
[7]  
Lopes Miguel de Barros, 2002, FEMS Yeast Research, V1, P323
[8]  
LYONETTE DRM, 2000, POW ENG SOC WINT M 2, V3, P1827